Vikram Solar SOMERA VSMHBB6036005 — CEC Solar Module Specifications

Manufacturer: Vikram Solar Registry: CEC Verified Engineering Specification

Vikram Solar SOMERA VSMHBB6036005 is a 360.0 W STC (332.4 W PTC) Mono-c-Si solar module ranking #12,385 of 21,677 CEC listings (below all-CEC median; higher than 41.3% of peers). It delivers 19.35% efficiency, 40.9 V Voc at 25 C, and 45.02 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
360.0 W
PTC Wattage
332.4 W
Voc @ 25C
40.9 V
Efficiency
19.35%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Vikram Solar SOMERA VSMHBB6036005 Compare Against Peer CEC Listings?

Solar engineering breakdown for Vikram Solar SOMERA VSMHBB6036005: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from Vikram Solar and peers, Vikram Solar SOMERA VSMHBB6036005 stands 50.0 W below the 410.0 W Mono-c-Si median and strong 92.3% PTC-to-STC heat retention (#13,268 of 21,677). Sizing 6 kW (17 panels) to 10 kW (28 panels) yields $1,532-$2,523/yr in baseline US bill offset. Mid-range 40.9 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F.

Where Does Vikram Solar SOMERA VSMHBB6036005 Fall Across Listed CEC Models?

Distribution marker showing Vikram Solar SOMERA VSMHBB6036005 (360.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Vikram Solar SOMERA VSMHBB6036005 (360.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCVikram Solar SOMER: 360.0 W

What Dataset Percentiles Define Vikram Solar SOMERA VSMHBB6036005?

Dataset percentiles tracking Vikram Solar SOMERA VSMHBB6036005 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

Vikram Solar SOMERA VSMHBB6036005 Engineering BenchmarksPercentile comparison of Vikram Solar SOMERA VSMHBB6036005 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage360.0 WPTC/STC Retention92.3%Module Efficiency19.35%

What Do the Dataset Ranks Show for Vikram Solar SOMERA VSMHBB6036005?

Benchmark highlights for Vikram Solar SOMERA VSMHBB6036005 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #12,385 / 21,677

360.0 W STC · Higher Than 41.3%

360.0 W STC (-25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #12,558

19.35% Aperture Efficiency

Power density 193.5 W/m2 (0.56 percentage points below 19.91% CEC median). PTC/STC ratio: 92.3% (rank #13,268).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 45.02 V at -10 C (585.3 V string) and 46.2 V at -20 C (12 max).

8 kW Reference Array

23 Panels = 8,280 W STC

Occupies 42.8 m2 (460 sq ft) producing 7,645 W PTC; NEC 690.8 OCPD floor is 17.71 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 40.9 * (1 + (-0.288/100) * (-10 - 25)) = 45.02 V | OCPD = 1.56 * 11.35 = 17.71 A

Inputs from CEC Modules.csv for Vikram Solar SOMERA VSMHBB6036005: Voc=40.9 V, beta_Voc=-0.288%/C, Isc=11.35 A, STC=360.0 W, Area=1.86 m2.

Result: 13 panels max on 600 V (585.3 V); 23 panels for 8 kW (460 sq ft).

What Are the Published CEC Specifications for Vikram Solar SOMERA VSMHBB6036005?

Official CEC datasheet figures for Vikram Solar SOMERA VSMHBB6036005 (Mono-c-Si) used in utility interconnection and permit reviews. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Official California Energy Commission (NREL SAM) test parameters for Vikram Solar SOMERA VSMHBB6036005.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 360.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 332.4 W (92.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 40.9 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 11.35 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 34.7 V / 10.41 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.288 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 19.35% (1.86 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many Vikram Solar SOMERA VSMHBB6036005 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Vikram Solar SOMERA VSMHBB6036005 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 17 6.12 kW 340 sq ft $1,532 $2,590
8 kW Class 23 8.28 kW 460 sq ft $2,072 $3,504
10 kW Class 28 10.08 kW 561 sq ft $2,523 $4,266

How Many Vikram Solar SOMERA VSMHBB6036005 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Vikram Solar SOMERA VSMHBB6036005 (45.02 V at 14 F).

Computed from Voc=40.9V and beta_Voc=-0.288%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 46.2 V 12 panels 554.4 V 21 panels
-10 C (14 F) 45.02 V 13 panels 585.3 V 22 panels
0 C (32 F) 43.84 V 13 panels 569.9 V 22 panels
25 C (77 F STC) 40.9 V 14 panels 572.6 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to Vikram Solar SOMERA VSMHBB6036005?

Competing CEC solar panels closest to Vikram Solar SOMERA VSMHBB6036005 in nameplate wattage and Voc, starting with DualSun SAS DualSun 360M-120-00.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
DualSun SAS DualSun 360M-120-00
DualSun SAS
360.0 W Tie (0 W) 40.9 V 19.89% 93.3%
DualSun SAS DualSun 360M-120-01
DualSun SAS
360.0 W Tie (0 W) 40.9 V 19.89% 93.2%
CSI Solar Co Ltd CS3L-360P
CSI Solar Co Ltd
360.0 W Tie (0 W) 40.6 V 20.11% 92.4%
Apollo Renewables Inc Apollo-M660BH-360BB
Apollo Renewables Inc
360.0 W Tie (0 W) 40.5 V 20.0% 93.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Vikram Solar SOMERA VSMHBB6036005?

Evaluate Vikram Solar SOMERA VSMHBB6036005 (360.0 W STC, 40.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Vikram Solar SOMERA VSMHBB6036005 reaches 46.2 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 23 panels for an 8 kW build require 460 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 23 panels (460 sq ft).
  • 2026 tax credit baseline: cash residential installs of Vikram Solar SOMERA VSMHBB6036005 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Vikram Solar SOMERA VSMHBB6036005 8 kW Residential Fit

Needs 23 modules (460 sq ft) with a 20 A string OCPD, offsetting ~$2,072/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare DualSun SAS DualSun 360M-120-00.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 332.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Vikram Solar SOMERA VSMHBB6036005 by Vikram Solar grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Vikram Solar SOMERA VSMHBB6036005?

Multiplying Vikram Solar SOMERA VSMHBB6036005's 11.35 A short-circuit current by 1.56 equals 17.71 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can Vikram Solar SOMERA VSMHBB6036005 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 45.02 V cold Voc at 14 F and handles 11.35 A Isc; string inverters cap Vikram Solar SOMERA VSMHBB6036005 at 13 panels on 600 V.

Is Vikram Solar SOMERA VSMHBB6036005 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Vikram Solar SOMERA VSMHBB6036005 rely on utility bill offset (~$2,072/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes