Skip to main content
WireAndSun
Calculators
CEC PV Module

Vikram Solar PARADEA VSMDH7253505 — CEC Solar Module Specifications

Manufacturer: Vikram Solar Registry: CEC Verified Engineering Specification

Vikram Solar PARADEA VSMDH7253505 is a 535.0 W STC (493.2 W PTC) Mono-c-Si solar module ranking #3,537 of 21,677 CEC listings (top 17.5%; higher than 82.5% of peers). It delivers 21.4% efficiency, 49.4 V Voc at 25 C, and 54.55 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
535.0 W
PTC Wattage
493.2 W
Voc @ 25C
49.4 V
Efficiency
21.4%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Vikram Solar PARADEA VSMDH7253505 Compare Against Peer CEC Listings?

How Vikram Solar Vikram Solar PARADEA VSMDH7253505 handles rooftop heat (493.2 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Vikram Solar PARADEA VSMDH7253505 exhibits 13.56 A short-circuit current, requiring a 21.15 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #3,537 of 21,677 (125.0 W above the 410.0 W Mono-c-Si median), this large-format commercial and ground-mount module covers 37.5 m2 for an 8 kW system (19 panels for 10 kW). Higher 49.4 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).

Where Does Vikram Solar PARADEA VSMDH7253505 Fall Across Listed CEC Models?

Where Vikram Solar PARADEA VSMDH7253505 (535.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Vikram Solar PARADEA VSMDH7253505 (535.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCVikram Solar PARAD: 535.0 W

What Dataset Percentiles Define Vikram Solar PARADEA VSMDH7253505?

Percentile placement of Vikram Solar PARADEA VSMDH7253505 across power density (214.0 W/m2), thermal retention, and nameplate STC wattage.

Vikram Solar PARADEA VSMDH7253505 Engineering BenchmarksPercentile comparison of Vikram Solar PARADEA VSMDH7253505 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage535.0 WPTC/STC Retention92.2%Module Efficiency21.4%

What Do the Dataset Ranks Show for Vikram Solar PARADEA VSMDH7253505?

Four critical engineering numbers homeowners and solar installers check first when reviewing Vikram Solar PARADEA VSMDH7253505 specifications. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Rank #3,537 / 21,677

Top 17.5% STC Output

535.0 W STC (+150.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #4,753

21.4% Aperture Efficiency

Power density 214.0 W/m2 (1.49 percentage points above 19.91% CEC median). PTC/STC ratio: 92.2% (rank #13,542).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.55 V at -10 C (545.5 V string) and 56.02 V at -20 C (10 max).

8 kW Reference Array

15 Panels = 8,025 W STC

Occupies 37.5 m2 (404 sq ft) producing 7,398 W PTC; NEC 690.8 OCPD floor is 21.15 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.4 * (1 + (-0.298/100) * (-10 - 25)) = 54.55 V | OCPD = 1.56 * 13.56 = 21.15 A

Inputs from CEC Modules.csv for Vikram Solar PARADEA VSMDH7253505: Voc=49.4 V, beta_Voc=-0.298%/C, Isc=13.56 A, STC=535.0 W, Area=2.5 m2.

Result: 10 panels max on 600 V (545.5 V); 15 panels for 8 kW (404 sq ft).

What Are the Published CEC Specifications for Vikram Solar PARADEA VSMDH7253505?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Vikram Solar PARADEA VSMDH7253505.

Official California Energy Commission (NREL SAM) test parameters for Vikram Solar PARADEA VSMDH7253505.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 535.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 493.2 W (92.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 49.4 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.56 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 41.6 V / 12.87 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.298 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.4% (2.5 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Bifacial glass-glass

How Many Vikram Solar PARADEA VSMDH7253505 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Vikram Solar PARADEA VSMDH7253505 (535.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 12 6.42 kW 323 sq ft $1,607 $2,717
8 kW Class 15 8.03 kW 404 sq ft $2,010 $3,398
10 kW Class 19 10.16 kW 511 sq ft $2,543 $4,300

How Many Vikram Solar PARADEA VSMDH7253505 Modules Fit in a Cold-Weather String?

Maximum series module counts for Vikram Solar PARADEA VSMDH7253505 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=49.4V and beta_Voc=-0.298%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 56.02 V 10 panels 560.2 V 17 panels
-10 C (14 F) 54.55 V 10 panels 545.5 V 18 panels
0 C (32 F) 53.08 V 11 panels 583.9 V 18 panels
25 C (77 F STC) 49.4 V 12 panels 592.8 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to Vikram Solar PARADEA VSMDH7253505?

Alternative CEC solar modules from competing brands near Vikram Solar PARADEA VSMDH7253505 (535.0 W), including ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE535MD-144BS.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE535MD-144BS
ALTERNATIVE ENERGY (AE) SOLAR CO LTD
535.0 W Tie (0 W) 49.4 V 20.9% 93.3%
ES Foundry Corp ES-DP8-H72L-535W
ES Foundry Corp
535.0 W Tie (0 W) 49.4 V 21.49% 93.2%
Jiangsu Green Energy Power Technology Co Ltd GEO-PM10-72D535
Jiangsu Green Energy Power Technology Co Ltd
535.0 W Tie (0 W) 49.4 V 21.23% 93.9%
Jiangsu Green Energy Power Technology Co Ltd GEO-PM10-72TS535
Jiangsu Green Energy Power Technology Co Ltd
535.0 W Tie (0 W) 49.4 V 21.23% 93.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Vikram Solar PARADEA VSMDH7253505?

Evaluate Vikram Solar PARADEA VSMDH7253505 (535.0 W STC, 49.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Vikram Solar PARADEA VSMDH7253505 reaches 56.02 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 15 panels for an 8 kW build require 404 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of Vikram Solar PARADEA VSMDH7253505 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Vikram Solar PARADEA VSMDH7253505 8 kW Residential Fit

Needs 15 modules (404 sq ft) with a 25 A string OCPD, offsetting ~$2,010/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE535MD-144BS.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 493.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Vikram Solar PARADEA VSMDH7253505 by Vikram Solar grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Vikram Solar PARADEA VSMDH7253505 PTC wattage (493.2 W) lower than STC (535.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 493.2 W PTC (92.2% retention) across Vikram Solar PARADEA VSMDH7253505's 2.5 m2 aperture.

Who should skip Vikram Solar PARADEA VSMDH7253505 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 15 Vikram Solar PARADEA VSMDH7253505 panels (404 sq ft) leave unusable roof gaps vs. ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE535MD-144BS.

What is the 1,000 V commercial string limit for Vikram Solar PARADEA VSMDH7253505?

On 1,000 V commercial inverters at -10 C (54.55 V cold Voc), Vikram Solar PARADEA VSMDH7253505 fits up to 18 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Vikram Solar PARADEA VSMDH7253505.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.