Vikram Solar SOMERA VSMHBB6035505 is a 355.0 W STC (327.7 W PTC) Mono-c-Si solar module ranking #12,724 of 21,677 CEC listings (below all-CEC median; higher than 39.9% of peers). It delivers 19.09% efficiency, 40.8 V Voc at 25 C, and 44.91 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 355.0 W
- PTC Wattage
- 327.7 W
- Voc @ 25C
- 40.8 V
- Efficiency
- 19.09%
How Does Vikram Solar SOMERA VSMHBB6035505 Compare Against Peer CEC Listings?
Solar engineering breakdown for Vikram Solar SOMERA VSMHBB6035505: PTC thermal retention, roof footprint, and cold Voc string bounds.
Measured at 355.0 W STC and 327.7 W PTC, Vikram Solar SOMERA VSMHBB6035505 sits -30.0 W vs all-CEC median (below all-CEC median; higher than 39.9% of peers) among 21,677 listed modules. Power density reaches 190.9 W/m2 (0.82 percentage points below 19.91% CEC median). Mid-range 40.8 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 22 panels in series. Alternative peer DualSun SAS DualSun 360M-120-00 rates 360.0 W.
Where Does Vikram Solar SOMERA VSMHBB6035505 Fall Across Listed CEC Models?
Distribution marker showing Vikram Solar SOMERA VSMHBB6035505 (355.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Vikram Solar SOMERA VSMHBB6035505?
Dataset percentiles tracking Vikram Solar SOMERA VSMHBB6035505 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Vikram Solar SOMERA VSMHBB6035505?
Benchmark highlights for Vikram Solar SOMERA VSMHBB6035505 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
355.0 W STC · Higher Than 39.9%
355.0 W STC (-30.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
19.09% Aperture Efficiency
Power density 190.9 W/m2 (0.82 percentage points below 19.91% CEC median). PTC/STC ratio: 92.3% (rank #13,268).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 44.91 V at -10 C (583.8 V string) and 46.09 V at -20 C (13 max).
23 Panels = 8,165 W STC
Occupies 42.8 m2 (460 sq ft) producing 7,537 W PTC; NEC 690.8 OCPD floor is 17.55 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 40.8 * (1 + (-0.288/100) * (-10 - 25)) = 44.91 V | OCPD = 1.56 * 11.25 = 17.55 A
Inputs from CEC Modules.csv for Vikram Solar SOMERA VSMHBB6035505: Voc=40.8 V, beta_Voc=-0.288%/C, Isc=11.25 A, STC=355.0 W, Area=1.86 m2.
Result: 13 panels max on 600 V (583.8 V); 23 panels for 8 kW (460 sq ft).
What Are the Published CEC Specifications for Vikram Solar SOMERA VSMHBB6035505?
Official CEC datasheet figures for Vikram Solar SOMERA VSMHBB6035505 (Mono-c-Si) used in utility interconnection and permit reviews. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 355.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 327.7 W (92.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 40.8 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 11.25 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 34.7 V / 10.27 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.288 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 19.09% (1.86 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many Vikram Solar SOMERA VSMHBB6035505 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Vikram Solar SOMERA VSMHBB6035505 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 17 | 6.04 kW | 340 sq ft | $1,512 | $2,556 |
| 8 kW Class | 23 | 8.16 kW | 460 sq ft | $2,042 | $3,454 |
| 10 kW Class | 29 | 10.29 kW | 581 sq ft | $2,575 | $4,355 |
How Many Vikram Solar SOMERA VSMHBB6035505 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Vikram Solar SOMERA VSMHBB6035505 (44.91 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 46.09 V | 13 panels | 599.2 V | 21 panels |
| -10 C (14 F) | 44.91 V | 13 panels | 583.8 V | 22 panels |
| 0 C (32 F) | 43.74 V | 13 panels | 568.6 V | 22 panels |
| 25 C (77 F STC) | 40.8 V | 14 panels | 571.2 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to Vikram Solar SOMERA VSMHBB6035505?
Competing CEC solar panels closest to Vikram Solar SOMERA VSMHBB6035505 in nameplate wattage and Voc, starting with DualSun SAS DualSun 360M-120-00.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| DualSun SAS DualSun 360M-120-00 DualSun SAS |
360.0 W | +5.0 W | 40.9 V | 19.89% | 93.3% |
| DualSun SAS DualSun 360M-120-01 DualSun SAS |
360.0 W | +5.0 W | 40.9 V | 19.89% | 93.2% |
| CSI Solar Co Ltd CS3L-360P CSI Solar Co Ltd |
360.0 W | +5.0 W | 40.6 V | 20.11% | 92.4% |
| Apollo Renewables Inc Apollo-M660BH-360BB Apollo Renewables Inc |
360.0 W | +5.0 W | 40.5 V | 20.0% | 93.6% |
What Are the Design Limits and Best-Fit Uses for Vikram Solar SOMERA VSMHBB6035505?
Evaluate Vikram Solar SOMERA VSMHBB6035505 (355.0 W STC, 40.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Vikram Solar SOMERA VSMHBB6035505 reaches 46.09 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 23 panels for an 8 kW build require 460 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 23 panels (460 sq ft).
- 2026 tax credit baseline: cash residential installs of Vikram Solar SOMERA VSMHBB6035505 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Vikram Solar SOMERA VSMHBB6035505 8 kW Residential Fit
Needs 23 modules (460 sq ft) with a 20 A string OCPD, offsetting ~$2,042/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare DualSun SAS DualSun 360M-120-00.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 327.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Vikram Solar SOMERA VSMHBB6035505 by Vikram Solar grounded in CEC test data and NEC 690.7/690.8 limits.
How many Vikram Solar SOMERA VSMHBB6035505 panels fit on a 600 V winter solar string?
At -10 C (14 F), Vikram Solar SOMERA VSMHBB6035505 cold Voc rises from 40.8 V to 44.91 V (beta_Voc -0.288%/C), capping a 600 V string at 13 panels (583.8 V).
How much roof area does an 8 kW array of Vikram Solar SOMERA VSMHBB6035505 need?
An 8 kW DC system uses 23 Vikram Solar SOMERA VSMHBB6035505 modules (8,165 W STC / 7,537 W PTC), covering roughly 460 sq ft and saving ~$2,042/yr at 18.54 c/kWh.
How does Vikram Solar SOMERA VSMHBB6035505 compare against DualSun SAS DualSun 360M-120-00?
Vikram Solar SOMERA VSMHBB6035505 outputs 355.0 W STC (40.8 V Voc, rank #12,724 of 21,677), while DualSun SAS DualSun 360M-120-00 delivers 360.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)