Trina Solar TSM-485DE15V(II) is a 485.0 W STC (453.8 W PTC) Mono-c-Si solar module ranking #4,730 of 21,677 CEC listings (top 22.2%; higher than 77.8% of peers). It delivers 20.82% efficiency, 43.3 V Voc at 25 C, and 47.47 V cold Voc at -10 C (12 panels max per 600 V string).
- STC Wattage
- 485.0 W
- PTC Wattage
- 453.8 W
- Voc @ 25C
- 43.3 V
- Efficiency
- 20.82%
How Does Trina Solar TSM-485DE15V(II) Compare Against Peer CEC Listings?
Solar engineering breakdown for Trina Solar TSM-485DE15V(II): PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from Trina Solar and peers, Trina Solar TSM-485DE15V(II) stands 75.0 W above the 410.0 W Mono-c-Si median and strong 93.6% PTC-to-STC heat retention (#6,726 of 21,677). Sizing 6 kW (13 panels) to 10 kW (21 panels) yields $1,577-$2,550/yr in baseline US bill offset. Mid-range 43.3 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F.
Where Does Trina Solar TSM-485DE15V(II) Fall Across Listed CEC Models?
Distribution marker showing Trina Solar TSM-485DE15V(II) (485.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Trina Solar TSM-485DE15V(II)?
Dataset percentiles tracking Trina Solar TSM-485DE15V(II) power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Trina Solar TSM-485DE15V(II)?
Benchmark highlights for Trina Solar TSM-485DE15V(II) covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 22.2% STC Output
485.0 W STC (+100.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.82% Aperture Efficiency
Power density 208.2 W/m2 (0.91 percentage points above 19.91% CEC median). PTC/STC ratio: 93.6% (rank #6,726).
12 Panels Max @ -10 C (600 V)
Cold Voc reaches 47.47 V at -10 C (569.6 V string) and 48.66 V at -20 C (12 max).
17 Panels = 8,245 W STC
Occupies 39.6 m2 (426 sq ft) producing 7,715 W PTC; NEC 690.8 OCPD floor is 21.79 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 43.3 * (1 + (-0.275/100) * (-10 - 25)) = 47.47 V | OCPD = 1.56 * 13.97 = 21.79 A
Inputs from CEC Modules.csv for Trina Solar TSM-485DE15V(II): Voc=43.3 V, beta_Voc=-0.275%/C, Isc=13.97 A, STC=485.0 W, Area=2.33 m2.
Result: 12 panels max on 600 V (569.6 V); 17 panels for 8 kW (426 sq ft).
What Are the Published CEC Specifications for Trina Solar TSM-485DE15V(II)?
Official CEC datasheet figures for Trina Solar TSM-485DE15V(II) (Mono-c-Si) used in utility interconnection and permit reviews. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 485.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 453.8 W (93.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 43.3 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.97 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 36.4 V / 13.33 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.275 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.82% (2.33 m2) | Array roof footprint density |
| Cell Count & Technology | 126 cells (Mono-c-Si) | Monofacial backsheet |
How Many Trina Solar TSM-485DE15V(II) Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Trina Solar TSM-485DE15V(II) modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 13 | 6.3 kW | 326 sq ft | $1,577 | $2,666 |
| 8 kW Class | 17 | 8.24 kW | 426 sq ft | $2,062 | $3,487 |
| 10 kW Class | 21 | 10.19 kW | 527 sq ft | $2,550 | $4,313 |
Which Sibling Wattage & Trim Variants Belong to This Trina Solar Series?
Consolidated Trina Solar wattage variants sharing the Trina Solar TSM-485DE15V(II) mechanical and cell layout. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Trina Solar TSM-475DE15V(II) | 475.0 W | 444.2 W | 43.1 V | 36.2 V | 20.39% |
| Trina Solar TSM-480DE15V(II) | 480.0 W | 449.0 W | 43.2 V | 36.3 V | 20.6% |
| Trina Solar TSM-485DE15V(II) | 485.0 W | 453.8 W | 43.3 V | 36.4 V | 20.82% |
| Trina Solar TSM-490DE15V(II) | 490.0 W | 458.6 W | 43.4 V | 36.5 V | 21.03% |
How Many Trina Solar TSM-485DE15V(II) Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Trina Solar TSM-485DE15V(II) (47.47 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 48.66 V | 12 panels | 583.9 V | 20 panels |
| -10 C (14 F) | 47.47 V | 12 panels | 569.6 V | 21 panels |
| 0 C (32 F) | 46.28 V | 12 panels | 555.4 V | 21 panels |
| 25 C (77 F STC) | 43.3 V | 13 panels | 562.9 V | 23 panels |
Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-485DE15V(II)?
Competing CEC solar panels closest to Trina Solar TSM-485DE15V(II) in nameplate wattage and Voc, starting with Hanersun Energy Co Ltd HN18N-60HT485W.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Hanersun Energy Co Ltd HN18N-60HT485W Hanersun Energy Co Ltd |
485.0 W | Tie (0 W) | 43.0 V | 22.99% | 94.9% |
| Auxin Solar AXN10M485B Auxin Solar |
485.0 W | Tie (0 W) | 43.98 V | 22.56% | 92.0% |
| Auxin Solar AXN10M485W Auxin Solar |
485.0 W | Tie (0 W) | 43.98 V | 22.56% | 91.8% |
| CSI Solar Co Ltd CS61-60TM-485H CSI Solar Co Ltd |
485.0 W | Tie (0 W) | 42.6 V | 22.15% | 94.7% |
What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-485DE15V(II)?
Evaluate Trina Solar TSM-485DE15V(II) (485.0 W STC, 43.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-485DE15V(II) reaches 48.66 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 17 panels for an 8 kW build require 426 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 17 panels (426 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Trina Solar TSM-485DE15V(II) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Trina Solar TSM-485DE15V(II) 8 kW Residential Fit
Needs 17 modules (426 sq ft) with a 25 A string OCPD, offsetting ~$2,062/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare Hanersun Energy Co Ltd HN18N-60HT485W.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 453.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Trina Solar TSM-485DE15V(II) by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Trina Solar TSM-485DE15V(II)?
Multiplying Trina Solar TSM-485DE15V(II)'s 13.97 A short-circuit current by 1.56 equals 21.79 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can Trina Solar TSM-485DE15V(II) pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 47.47 V cold Voc at 14 F and handles 13.97 A Isc; string inverters cap Trina Solar TSM-485DE15V(II) at 12 panels on 600 V.
Is Trina Solar TSM-485DE15V(II) eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Trina Solar TSM-485DE15V(II) rely on utility bill offset (~$2,062/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)