Skip to main content
WireAndSun
Calculators
CEC PV Module

Thornova Solar TS-SBT60(510) — CEC Solar Module Specifications

Manufacturer: Thornova Solar Registry: CEC Verified Engineering Specification

Thornova Solar TS-SBT60(510) is a 510.0 W STC (485.7 W PTC) Mono-c-Si solar module ranking #4,386 of 21,677 CEC listings (top 20.5%; higher than 79.5% of peers). It delivers 23.83% efficiency, 44.02 V Voc at 25 C, and 47.58 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
510.0 W
PTC Wattage
485.7 W
Voc @ 25C
44.02 V
Efficiency
23.83%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Thornova Solar TS-SBT60(510) Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Thornova Solar TS-SBT60(510) (Mono-c-Si) residential solar systems.

Homeowners evaluating Thornova Solar TS-SBT60(510) need 12 panels for 6 kW or 16 panels (369 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 16 panels (369 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.231%/C) pushes open-circuit voltage to 47.58 V at 14 F and 48.6 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Thornova Solar TS-SBT60(510) Fall Across Listed CEC Models?

Comparison of Thornova Solar TS-SBT60(510) (510.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Thornova Solar TS-SBT60(510) (510.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCThornova Solar TS-: 510.0 W

What Dataset Percentiles Define Thornova Solar TS-SBT60(510)?

Relative ranking of Thornova Solar TS-SBT60(510) across nameplate watts, 95.2% PTC thermal ratio, and module aperture efficiency.

Thornova Solar TS-SBT60(510) Engineering BenchmarksPercentile comparison of Thornova Solar TS-SBT60(510) wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage510.0 WPTC/STC Retention95.2%Module Efficiency23.83%

What Do the Dataset Ranks Show for Thornova Solar TS-SBT60(510)?

Summary of Thornova Solar TS-SBT60(510) output rank, 8 kW array size (16 panels), efficiency rating, and 600 V string limit.

Rank #4,386 / 21,677

Top 20.5% STC Output

510.0 W STC (+125.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #293

23.83% Aperture Efficiency

Power density 238.3 W/m2 (3.92 percentage points above 19.91% CEC median). PTC/STC ratio: 95.2% (rank #399).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 47.58 V at -10 C (571.0 V string) and 48.6 V at -20 C (12 max).

8 kW Reference Array

16 Panels = 8,160 W STC

Occupies 34.2 m2 (369 sq ft) producing 7,771 W PTC; NEC 690.8 OCPD floor is 21.98 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 44.02 * (1 + (-0.231/100) * (-10 - 25)) = 47.58 V | OCPD = 1.56 * 14.09 = 21.98 A

Inputs from CEC Modules.csv for Thornova Solar TS-SBT60(510): Voc=44.02 V, beta_Voc=-0.231%/C, Isc=14.09 A, STC=510.0 W, Area=2.14 m2.

Result: 12 panels max on 600 V (571.0 V); 16 panels for 8 kW (369 sq ft).

What Are the Published CEC Specifications for Thornova Solar TS-SBT60(510)?

Complete CEC test sheet for Thornova Solar TS-SBT60(510) including Isc (14.09 A), Voc (44.02 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Thornova Solar TS-SBT60(510).
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 510.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 485.7 W (95.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 44.02 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 14.09 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 37.61 V / 13.57 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.231 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 23.83% (2.14 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many Thornova Solar TS-SBT60(510) Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Thornova Solar TS-SBT60(510).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 12 6.12 kW 276 sq ft $1,532 $2,590
8 kW Class 16 8.16 kW 369 sq ft $2,042 $3,454
10 kW Class 20 10.2 kW 461 sq ft $2,553 $4,317

How Many Thornova Solar TS-SBT60(510) Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Thornova Solar TS-SBT60(510) (44.02 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=44.02V and beta_Voc=-0.231%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 48.6 V 12 panels 583.2 V 20 panels
-10 C (14 F) 47.58 V 12 panels 571.0 V 21 panels
0 C (32 F) 46.56 V 12 panels 558.7 V 21 panels
25 C (77 F STC) 44.02 V 13 panels 572.3 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to Thornova Solar TS-SBT60(510)?

Four comparable CEC modules such as Auxin Solar AXN10M510W (510.0 W) for side-by-side solar quote checks. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Auxin Solar AXN10M510W
Auxin Solar
510.0 W Tie (0 W) 44.3 V 23.72% 91.9%
CSI Solar Co Ltd CS61-60TM-510H
CSI Solar Co Ltd
510.0 W Tie (0 W) 43.6 V 23.29% 94.8%
Elin Energy (Sirius PV) ELNSM66M-HC-510
Elin Energy (Sirius PV)
510.0 W Tie (0 W) 46.05 V 21.61% 94.3%
Elin Energy (Sirius PV) ELNSM66M-HC-LV-510
Elin Energy (Sirius PV)
510.0 W Tie (0 W) 46.05 V 21.61% 94.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Thornova Solar TS-SBT60(510)?

Evaluate Thornova Solar TS-SBT60(510) (510.0 W STC, 44.02 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Thornova Solar TS-SBT60(510) reaches 48.6 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 16 panels for an 8 kW build require 369 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 16 panels (369 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Thornova Solar TS-SBT60(510) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Thornova Solar TS-SBT60(510) 8 kW Residential Fit

Needs 16 modules (369 sq ft) with a 25 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare Auxin Solar AXN10M510W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 485.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Thornova Solar TS-SBT60(510) by Thornova Solar grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Thornova Solar TS-SBT60(510) PTC wattage (485.7 W) lower than STC (510.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 485.7 W PTC (95.2% retention) across Thornova Solar TS-SBT60(510)'s 2.14 m2 aperture.

Who should skip Thornova Solar TS-SBT60(510) on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 16 Thornova Solar TS-SBT60(510) panels (369 sq ft) leave unusable roof gaps vs. Auxin Solar AXN10M510W.

What is the 1,000 V commercial string limit for Thornova Solar TS-SBT60(510)?

On 1,000 V commercial inverters at -10 C (47.58 V cold Voc), Thornova Solar TS-SBT60(510) fits up to 21 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Thornova Solar TS-SBT60(510).

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.