CSI Solar Co Ltd CS61-60TM-510H is a 510.0 W STC (483.5 W PTC) Mono-c-Si solar module ranking #4,386 of 21,677 CEC listings (top 20.5%; higher than 79.5% of peers). It delivers 23.29% efficiency, 43.6 V Voc at 25 C, and 47.37 V cold Voc at -10 C (12 panels max per 600 V string).
- STC Wattage
- 510.0 W
- PTC Wattage
- 483.5 W
- Voc @ 25C
- 43.6 V
- Efficiency
- 23.29%
How Does CSI Solar Co Ltd CS61-60TM-510H Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for CSI Solar Co Ltd CS61-60TM-510H (Mono-c-Si) residential solar systems.
CSI Solar Co Ltd CS61-60TM-510H delivers 232.9 W/m2 (3.38 percentage points above 19.91% CEC median) and strong 94.8% PTC-to-STC heat retention (#1,790 of 21,677), placing it as a modern high-density residential and light-commercial module well-proportioned for residential pitched roofs needing 16 panels (377 sq ft) for an 8 kW array. At -4 F (-20 C), string voltage climbs to 48.45 V per unit, capping 600 V circuits at 12 panels. Compare specs directly with Auxin Solar AXN10M510W (510.0 W).
Where Does CSI Solar Co Ltd CS61-60TM-510H Fall Across Listed CEC Models?
Comparison of CSI Solar Co Ltd CS61-60TM-510H (510.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define CSI Solar Co Ltd CS61-60TM-510H?
Relative ranking of CSI Solar Co Ltd CS61-60TM-510H across nameplate watts, 94.8% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for CSI Solar Co Ltd CS61-60TM-510H?
Summary of CSI Solar Co Ltd CS61-60TM-510H output rank, 8 kW array size (16 panels), efficiency rating, and 600 V string limit.
Top 20.5% STC Output
510.0 W STC (+125.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
23.29% Aperture Efficiency
Power density 232.9 W/m2 (3.38 percentage points above 19.91% CEC median). PTC/STC ratio: 94.8% (rank #1,790).
12 Panels Max @ -10 C (600 V)
Cold Voc reaches 47.37 V at -10 C (568.4 V string) and 48.45 V at -20 C (12 max).
16 Panels = 8,160 W STC
Occupies 35.0 m2 (377 sq ft) producing 7,736 W PTC; NEC 690.8 OCPD floor is 22.85 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 43.6 * (1 + (-0.247/100) * (-10 - 25)) = 47.37 V | OCPD = 1.56 * 14.65 = 22.85 A
Inputs from CEC Modules.csv for CSI Solar Co Ltd CS61-60TM-510H: Voc=43.6 V, beta_Voc=-0.247%/C, Isc=14.65 A, STC=510.0 W, Area=2.19 m2.
Result: 12 panels max on 600 V (568.4 V); 16 panels for 8 kW (377 sq ft).
What Are the Published CEC Specifications for CSI Solar Co Ltd CS61-60TM-510H?
Complete CEC test sheet for CSI Solar Co Ltd CS61-60TM-510H including Isc (14.65 A), Voc (43.6 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 510.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 483.5 W (94.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 43.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 14.65 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 37.0 V / 13.79 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.247 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 23.29% (2.19 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many CSI Solar Co Ltd CS61-60TM-510H Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using CSI Solar Co Ltd CS61-60TM-510H.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 12 | 6.12 kW | 283 sq ft | $1,532 | $2,590 |
| 8 kW Class | 16 | 8.16 kW | 377 sq ft | $2,042 | $3,454 |
| 10 kW Class | 20 | 10.2 kW | 471 sq ft | $2,553 | $4,317 |
Which Sibling Wattage & Trim Variants Belong to This CSI Solar Co Ltd Series?
Related CSI Solar Co Ltd power steps and black/silver trims consolidated into this CSI Solar Co Ltd CS61-60TM-510H series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS61-60TM-500H | 500.0 W | 473.8 W | 43.2 V | 36.6 V | 22.83% |
| CSI Solar Co Ltd CS61-60TM-505H | 505.0 W | 478.6 W | 43.4 V | 36.8 V | 23.06% |
| CSI Solar Co Ltd CS61-60TM-510H | 510.0 W | 483.5 W | 43.6 V | 37.0 V | 23.29% |
| CSI Solar Co Ltd CS61-60TM-515H | 515.0 W | 488.4 W | 43.8 V | 37.2 V | 23.52% |
How Many CSI Solar Co Ltd CS61-60TM-510H Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for CSI Solar Co Ltd CS61-60TM-510H (43.6 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 48.45 V | 12 panels | 581.4 V | 20 panels |
| -10 C (14 F) | 47.37 V | 12 panels | 568.4 V | 21 panels |
| 0 C (32 F) | 46.29 V | 12 panels | 555.5 V | 21 panels |
| 25 C (77 F STC) | 43.6 V | 13 panels | 566.8 V | 22 panels |
Which Cross-Brand Solar Modules Compare Closest to CSI Solar Co Ltd CS61-60TM-510H?
Four comparable CEC modules such as Auxin Solar AXN10M510W (510.0 W) for side-by-side solar quote checks. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Auxin Solar AXN10M510W Auxin Solar |
510.0 W | Tie (0 W) | 44.3 V | 23.72% | 91.9% |
| Elin Energy (Sirius PV) ELNSM66M-HC-510 Elin Energy (Sirius PV) |
510.0 W | Tie (0 W) | 46.05 V | 21.61% | 94.3% |
| Elin Energy (Sirius PV) ELNSM66M-HC-LV-510 Elin Energy (Sirius PV) |
510.0 W | Tie (0 W) | 46.05 V | 21.61% | 94.3% |
| DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW505M DONGGUAN SUNWORTH SOLAR ENERGY CO LTD |
505.0 W | -5.0 W | 45.16 V | 26.58% | 95.0% |
What Are the Design Limits and Best-Fit Uses for CSI Solar Co Ltd CS61-60TM-510H?
Evaluate CSI Solar Co Ltd CS61-60TM-510H (510.0 W STC, 43.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), CSI Solar Co Ltd CS61-60TM-510H reaches 48.45 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 16 panels for an 8 kW build require 377 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 16 panels (377 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of CSI Solar Co Ltd CS61-60TM-510H carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
CSI Solar Co Ltd CS61-60TM-510H 8 kW Residential Fit
Needs 16 modules (377 sq ft) with a 25 A string OCPD, offsetting ~$2,042/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare Auxin Solar AXN10M510W.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 483.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for CSI Solar Co Ltd CS61-60TM-510H by CSI Solar Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
How many CSI Solar Co Ltd CS61-60TM-510H panels fit on a 600 V winter solar string?
At -10 C (14 F), CSI Solar Co Ltd CS61-60TM-510H cold Voc rises from 43.6 V to 47.37 V (beta_Voc -0.247%/C), capping a 600 V string at 12 panels (568.4 V).
How much roof area does an 8 kW array of CSI Solar Co Ltd CS61-60TM-510H need?
An 8 kW DC system uses 16 CSI Solar Co Ltd CS61-60TM-510H modules (8,160 W STC / 7,736 W PTC), covering roughly 377 sq ft and saving ~$2,042/yr at 18.54 c/kWh.
How does CSI Solar Co Ltd CS61-60TM-510H compare against Auxin Solar AXN10M510W?
CSI Solar Co Ltd CS61-60TM-510H outputs 510.0 W STC (43.6 V Voc, rank #4,386 of 21,677), while Auxin Solar AXN10M510W delivers 510.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)