Thornova Solar TS-SB60(450) is a 450.0 W STC (424.4 W PTC) Mono-c-Si solar module ranking #5,679 of 21,677 CEC listings (top 27.8%; higher than 72.2% of peers). It delivers 21.03% efficiency, 41.46 V Voc at 25 C, and 44.9 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 450.0 W
- PTC Wattage
- 424.4 W
- Voc @ 25C
- 41.46 V
- Efficiency
- 21.03%
How Does Thornova Solar TS-SB60(450) Compare Against Peer CEC Listings?
How Thornova Solar Thornova Solar TS-SB60(450) handles rooftop heat (424.4 W PTC), 8 kW sizing, and cold winter string voltage.
Thornova Solar builds the Thornova Solar TS-SB60(450) (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 210.3 W/m2 (1.12 percentage points above 19.91% CEC median). Compared against CertainTeed CTM10450HC11-06 (450.0 W), this model holds strong 94.3% PTC-to-STC heat retention (#3,231 of 21,677). Mid-range 41.46 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F, while NEC 690.8 sets a 21.01 A overcurrent floor served by a 25 A breaker.
Where Does Thornova Solar TS-SB60(450) Fall Across Listed CEC Models?
Where Thornova Solar TS-SB60(450) (450.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Thornova Solar TS-SB60(450)?
Percentile placement of Thornova Solar TS-SB60(450) across power density (210.3 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Thornova Solar TS-SB60(450)?
Four critical engineering numbers homeowners and solar installers check first when reviewing Thornova Solar TS-SB60(450) specifications. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
Top 27.8% STC Output
450.0 W STC (+65.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.03% Aperture Efficiency
Power density 210.3 W/m2 (1.12 percentage points above 19.91% CEC median). PTC/STC ratio: 94.3% (rank #3,231).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 44.9 V at -10 C (583.7 V string) and 45.88 V at -20 C (13 max).
18 Panels = 8,100 W STC
Occupies 38.5 m2 (415 sq ft) producing 7,639 W PTC; NEC 690.8 OCPD floor is 21.01 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 41.46 * (1 + (-0.237/100) * (-10 - 25)) = 44.9 V | OCPD = 1.56 * 13.47 = 21.01 A
Inputs from CEC Modules.csv for Thornova Solar TS-SB60(450): Voc=41.46 V, beta_Voc=-0.237%/C, Isc=13.47 A, STC=450.0 W, Area=2.14 m2.
Result: 13 panels max on 600 V (583.7 V); 18 panels for 8 kW (415 sq ft).
What Are the Published CEC Specifications for Thornova Solar TS-SB60(450)?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Thornova Solar TS-SB60(450).
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 450.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 424.4 W (94.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 41.46 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.47 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 34.62 V / 13.01 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.237 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.03% (2.14 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many Thornova Solar TS-SB60(450) Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Thornova Solar TS-SB60(450) (450.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.3 kW | 322 sq ft | $1,577 | $2,666 |
| 8 kW Class | 18 | 8.1 kW | 415 sq ft | $2,027 | $3,428 |
| 10 kW Class | 23 | 10.35 kW | 530 sq ft | $2,591 | $4,380 |
How Many Thornova Solar TS-SB60(450) Modules Fit in a Cold-Weather String?
Maximum series module counts for Thornova Solar TS-SB60(450) from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 45.88 V | 13 panels | 596.4 V | 21 panels |
| -10 C (14 F) | 44.9 V | 13 panels | 583.7 V | 22 panels |
| 0 C (32 F) | 43.92 V | 13 panels | 571.0 V | 22 panels |
| 25 C (77 F STC) | 41.46 V | 14 panels | 580.4 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to Thornova Solar TS-SB60(450)?
Alternative CEC solar modules from competing brands near Thornova Solar TS-SB60(450) (450.0 W), including CertainTeed CTM10450HC11-06. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CertainTeed CTM10450HC11-06 CertainTeed |
450.0 W | Tie (0 W) | 41.18 V | 20.83% | 93.8% |
| CertainTeed CTM10455HC11-06 CertainTeed |
455.0 W | +5.0 W | 41.33 V | 21.06% | 93.8% |
| Energate Energy Inc EG-120L455W Energate Energy Inc |
455.0 W | +5.0 W | 41.33 V | 21.26% | 93.8% |
| Energate Enerji retim San A EG-120L455W Energate Enerji retim San A |
455.0 W | +5.0 W | 41.33 V | 21.26% | 93.8% |
What Are the Design Limits and Best-Fit Uses for Thornova Solar TS-SB60(450)?
Evaluate Thornova Solar TS-SB60(450) (450.0 W STC, 41.46 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Thornova Solar TS-SB60(450) reaches 45.88 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 415 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (415 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Thornova Solar TS-SB60(450) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Thornova Solar TS-SB60(450) 8 kW Residential Fit
Needs 18 modules (415 sq ft) with a 25 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare CertainTeed CTM10450HC11-06.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 424.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Thornova Solar TS-SB60(450) by Thornova Solar grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Thornova Solar TS-SB60(450)?
Multiplying Thornova Solar TS-SB60(450)'s 13.47 A short-circuit current by 1.56 equals 21.01 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can Thornova Solar TS-SB60(450) pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 44.9 V cold Voc at 14 F and handles 13.47 A Isc; string inverters cap Thornova Solar TS-SB60(450) at 13 panels on 600 V.
Is Thornova Solar TS-SB60(450) eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Thornova Solar TS-SB60(450) rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)