Skip to main content
WireAndSun
Calculators
CEC PV Module

Energate Enerji retim San A EG-120L455W — CEC Solar Module Specifications

Manufacturer: Energate Enerji retim San A Registry: CEC Verified Engineering Specification

Energate Enerji retim San A EG-120L455W is a 455.0 W STC (426.6 W PTC) Mono-c-Si solar module ranking #5,417 of 21,677 CEC listings (top 26.2%; higher than 73.8% of peers). It delivers 21.26% efficiency, 41.33 V Voc at 25 C, and 45.76 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
455.0 W
PTC Wattage
426.6 W
Voc @ 25C
41.33 V
Efficiency
21.26%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Energate Enerji retim San A EG-120L455W Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Energate Enerji retim San A EG-120L455W (Mono-c-Si) residential solar systems.

Homeowners evaluating Energate Enerji retim San A EG-120L455W need 14 panels for 6 kW or 18 panels (415 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 18 panels (415 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.306%/C) pushes open-circuit voltage to 45.76 V at 14 F and 47.02 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Energate Enerji retim San A EG-120L455W Fall Across Listed CEC Models?

Comparison of Energate Enerji retim San A EG-120L455W (455.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Energate Enerji retim San A EG-120L455W (455.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCEnergate Enerji re: 455.0 W

What Dataset Percentiles Define Energate Enerji retim San A EG-120L455W?

Relative ranking of Energate Enerji retim San A EG-120L455W across nameplate watts, 93.8% PTC thermal ratio, and module aperture efficiency.

Energate Enerji retim San A EG-120L455W Engineering BenchmarksPercentile comparison of Energate Enerji retim San A EG-120L455W wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage455.0 WPTC/STC Retention93.8%Module Efficiency21.26%

What Do the Dataset Ranks Show for Energate Enerji retim San A EG-120L455W?

Summary of Energate Enerji retim San A EG-120L455W output rank, 8 kW array size (18 panels), efficiency rating, and 600 V string limit.

Rank #5,417 / 21,677

Top 26.2% STC Output

455.0 W STC (+70.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #5,361

21.26% Aperture Efficiency

Power density 212.6 W/m2 (1.35 percentage points above 19.91% CEC median). PTC/STC ratio: 93.8% (rank #5,632).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 45.76 V at -10 C (594.9 V string) and 47.02 V at -20 C (12 max).

8 kW Reference Array

18 Panels = 8,190 W STC

Occupies 38.5 m2 (415 sq ft) producing 7,679 W PTC; NEC 690.8 OCPD floor is 21.73 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 41.33 * (1 + (-0.306/100) * (-10 - 25)) = 45.76 V | OCPD = 1.56 * 13.93 = 21.73 A

Inputs from CEC Modules.csv for Energate Enerji retim San A EG-120L455W: Voc=41.33 V, beta_Voc=-0.306%/C, Isc=13.93 A, STC=455.0 W, Area=2.14 m2.

Result: 13 panels max on 600 V (594.9 V); 18 panels for 8 kW (415 sq ft).

What Are the Published CEC Specifications for Energate Enerji retim San A EG-120L455W?

Complete CEC test sheet for Energate Enerji retim San A EG-120L455W including Isc (13.93 A), Voc (41.33 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Energate Enerji retim San A EG-120L455W.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 455.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 426.6 W (93.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 41.33 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.93 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 34.06 V / 13.36 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.306 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.26% (2.14 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many Energate Enerji retim San A EG-120L455W Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Energate Enerji retim San A EG-120L455W.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.37 kW 322 sq ft $1,594 $2,696
8 kW Class 18 8.19 kW 415 sq ft $2,050 $3,466
10 kW Class 22 10.01 kW 507 sq ft $2,505 $4,236

Which Sibling Wattage & Trim Variants Belong to This Energate Enerji retim San A Series?

Related Energate Enerji retim San A power steps and black/silver trims consolidated into this Energate Enerji retim San A EG-120L455W series guide.

Sibling CEC listings grouped into the Energate Enerji retim San A EG-120L455W wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Energate Enerji retim San A EG-120L450W 450.0 W 421.7 W 41.18 V 33.91 V 21.03%
Energate Enerji retim San A EG-120L455W 455.0 W 426.6 W 41.33 V 34.06 V 21.26%
Energate Enerji retim San A EG-120L460W 460.0 W 431.4 W 41.48 V 34.2 V 21.5%

How Many Energate Enerji retim San A EG-120L455W Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Energate Enerji retim San A EG-120L455W (41.33 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=41.33V and beta_Voc=-0.306%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 47.02 V 12 panels 564.2 V 21 panels
-10 C (14 F) 45.76 V 13 panels 594.9 V 21 panels
0 C (32 F) 44.49 V 13 panels 578.4 V 22 panels
25 C (77 F STC) 41.33 V 14 panels 578.6 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to Energate Enerji retim San A EG-120L455W?

Four comparable CEC modules such as CertainTeed CTM10455HC11-06 (455.0 W) for side-by-side solar quote checks. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CertainTeed CTM10455HC11-06
CertainTeed
455.0 W Tie (0 W) 41.33 V 21.06% 93.8%
Energate Energy Inc EG-120L455W
Energate Energy Inc
455.0 W Tie (0 W) 41.33 V 21.26% 93.8%
ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE455MD-120
ALTERNATIVE ENERGY (AE) SOLAR CO LTD
455.0 W Tie (0 W) 41.3 V 21.26% 92.9%
ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE455MD-120E
ALTERNATIVE ENERGY (AE) SOLAR CO LTD
455.0 W Tie (0 W) 41.3 V 21.26% 92.7%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Energate Enerji retim San A EG-120L455W?

Evaluate Energate Enerji retim San A EG-120L455W (455.0 W STC, 41.33 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Energate Enerji retim San A EG-120L455W reaches 47.02 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 18 panels for an 8 kW build require 415 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (415 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Energate Enerji retim San A EG-120L455W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Energate Enerji retim San A EG-120L455W 8 kW Residential Fit

Needs 18 modules (415 sq ft) with a 25 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare CertainTeed CTM10455HC11-06.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 426.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Energate Enerji retim San A EG-120L455W by Energate Enerji retim San A grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Energate Enerji retim San A EG-120L455W PTC wattage (426.6 W) lower than STC (455.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 426.6 W PTC (93.8% retention) across Energate Enerji retim San A EG-120L455W's 2.14 m2 aperture.

Who should skip Energate Enerji retim San A EG-120L455W on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 18 Energate Enerji retim San A EG-120L455W panels (415 sq ft) leave unusable roof gaps vs. CertainTeed CTM10455HC11-06.

What is the 1,000 V commercial string limit for Energate Enerji retim San A EG-120L455W?

On 1,000 V commercial inverters at -10 C (45.76 V cold Voc), Energate Enerji retim San A EG-120L455W fits up to 21 panels per series string.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.