Manufacturer: Energate Enerji retim San A Registry: CEC Verified Engineering Specification

Energate Enerji retim San A EG-108L410W is a 410.0 W STC (384.3 W PTC) Mono-c-Si solar module ranking #8,539 of 21,677 CEC listings (top 41.3%; higher than 58.7% of peers). It delivers 21.13% efficiency, 37.14 V Voc at 25 C, and 41.12 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
410.0 W
PTC Wattage
384.3 W
Voc @ 25C
37.14 V
Efficiency
21.13%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Energate Enerji retim San A EG-108L410W Compare Against Peer CEC Listings?

Solar engineering breakdown for Energate Enerji retim San A EG-108L410W: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from Energate Enerji retim San A and peers, Energate Enerji retim San A EG-108L410W stands equal to the 410.0 W Mono-c-Si median and strong 93.7% PTC-to-STC heat retention (#6,162 of 21,677). Sizing 6 kW (15 panels) to 10 kW (25 panels) yields $1,539-$2,565/yr in baseline US bill offset. Lower 37.14 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.

Where Does Energate Enerji retim San A EG-108L410W Fall Across Listed CEC Models?

Distribution marker showing Energate Enerji retim San A EG-108L410W (410.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Energate Enerji retim San A EG-108L410W (410.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCEnergate Enerji re: 410.0 W

What Dataset Percentiles Define Energate Enerji retim San A EG-108L410W?

Dataset percentiles tracking Energate Enerji retim San A EG-108L410W power output, thermal retention ratio, and aperture efficiency against 21,677 models.

Energate Enerji retim San A EG-108L410W Engineering BenchmarksPercentile comparison of Energate Enerji retim San A EG-108L410W wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage410.0 WPTC/STC Retention93.7%Module Efficiency21.13%

What Do the Dataset Ranks Show for Energate Enerji retim San A EG-108L410W?

Benchmark highlights for Energate Enerji retim San A EG-108L410W covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #8,539 / 21,677

Top 41.3% STC Output

410.0 W STC (+25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #5,767

21.13% Aperture Efficiency

Power density 211.3 W/m2 (1.22 percentage points above 19.91% CEC median). PTC/STC ratio: 93.7% (rank #6,162).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 41.12 V at -10 C (575.7 V string) and 42.25 V at -20 C (14 max).

8 kW Reference Array

20 Panels = 8,200 W STC

Occupies 38.8 m2 (418 sq ft) producing 7,686 W PTC; NEC 690.8 OCPD floor is 21.72 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.14 * (1 + (-0.306/100) * (-10 - 25)) = 41.12 V | OCPD = 1.56 * 13.92 = 21.72 A

Inputs from CEC Modules.csv for Energate Enerji retim San A EG-108L410W: Voc=37.14 V, beta_Voc=-0.306%/C, Isc=13.92 A, STC=410.0 W, Area=1.94 m2.

Result: 14 panels max on 600 V (575.7 V); 20 panels for 8 kW (418 sq ft).

What Are the Published CEC Specifications for Energate Enerji retim San A EG-108L410W?

Official CEC datasheet figures for Energate Enerji retim San A EG-108L410W (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for Energate Enerji retim San A EG-108L410W.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 410.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 384.3 W (93.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.14 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.92 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 30.62 V / 13.39 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.306 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.13% (1.94 m2) Array roof footprint density
Cell Count & Technology 54 cells (Mono-c-Si) Monofacial backsheet

How Many Energate Enerji retim San A EG-108L410W Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Energate Enerji retim San A EG-108L410W modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.15 kW 313 sq ft $1,539 $2,603
8 kW Class 20 8.2 kW 418 sq ft $2,052 $3,470
10 kW Class 25 10.25 kW 522 sq ft $2,565 $4,338

Which Sibling Wattage & Trim Variants Belong to This Energate Enerji retim San A Series?

Consolidated Energate Enerji retim San A wattage variants sharing the Energate Enerji retim San A EG-108L410W mechanical and cell layout.

Sibling CEC listings grouped into the Energate Enerji retim San A EG-108L410W wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Energate Enerji retim San A EG-108L400W 400.0 W 374.7 W 36.98 V 30.42 V 20.62%
Energate Enerji retim San A EG-108L405W 405.0 W 379.5 W 37.06 V 30.52 V 20.88%
Energate Enerji retim San A EG-108L410W 410.0 W 384.3 W 37.14 V 30.62 V 21.13%
Energate Enerji retim San A EG-108L415W 415.0 W 389.1 W 37.31 V 30.79 V 21.39%

How Many Energate Enerji retim San A EG-108L410W Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Energate Enerji retim San A EG-108L410W (41.12 V at 14 F).

Computed from Voc=37.14V and beta_Voc=-0.306%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 42.25 V 14 panels 591.5 V 23 panels
-10 C (14 F) 41.12 V 14 panels 575.7 V 24 panels
0 C (32 F) 39.98 V 15 panels 599.7 V 25 panels
25 C (77 F STC) 37.14 V 16 panels 594.2 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to Energate Enerji retim San A EG-108L410W?

Competing CEC solar panels closest to Energate Enerji retim San A EG-108L410W in nameplate wattage and Voc, starting with BYD Company Limited BYD410MLK-27.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
BYD Company Limited BYD410MLK-27
BYD Company Limited
410.0 W Tie (0 W) 37.14 V 21.13% 92.7%
CSI Solar Co Ltd CS6R-410MS-HL {Wht}
CSI Solar Co Ltd
410.0 W Tie (0 W) 37.2 V 21.03% 94.2%
ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE410MD-108
ALTERNATIVE ENERGY (AE) SOLAR CO LTD
410.0 W Tie (0 W) 37.23 V 21.24% 92.7%
Dehui Solar Power (Vietnam) CoLtd DH-M154W 410W
Dehui Solar Power (Vietnam) CoLtd
410.0 W Tie (0 W) 37.23 V 21.24% 92.7%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Energate Enerji retim San A EG-108L410W?

Evaluate Energate Enerji retim San A EG-108L410W (410.0 W STC, 37.14 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Energate Enerji retim San A EG-108L410W reaches 42.25 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 418 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (418 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Energate Enerji retim San A EG-108L410W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Energate Enerji retim San A EG-108L410W 8 kW Residential Fit

Needs 20 modules (418 sq ft) with a 25 A string OCPD, offsetting ~$2,052/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare BYD Company Limited BYD410MLK-27.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 384.3 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Energate Enerji retim San A EG-108L410W by Energate Enerji retim San A grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Energate Enerji retim San A EG-108L410W?

Multiplying Energate Enerji retim San A EG-108L410W's 13.92 A short-circuit current by 1.56 equals 21.72 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

Can Energate Enerji retim San A EG-108L410W pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 41.12 V cold Voc at 14 F and handles 13.92 A Isc; string inverters cap Energate Enerji retim San A EG-108L410W at 14 panels on 600 V.

Is Energate Enerji retim San A EG-108L410W eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Energate Enerji retim San A EG-108L410W rely on utility bill offset (~$2,052/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.