Thornova Solar TS-SB54(410) is a 410.0 W STC (386.6 W PTC) Mono-c-Si solar module ranking #8,539 of 21,677 CEC listings (top 41.3%; higher than 58.7% of peers). It delivers 21.13% efficiency, 37.68 V Voc at 25 C, and 40.81 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 410.0 W
- PTC Wattage
- 386.6 W
- Voc @ 25C
- 37.68 V
- Efficiency
- 21.13%
How Does Thornova Solar TS-SB54(410) Compare Against Peer CEC Listings?
Engineering position of Thornova Solar TS-SB54(410) (410.0 W STC) vs. Aptos Solar Technology LLC DNA-108-MF10-410W-USAptos1 across 5,889 CEC Mono-c-Si solar modules.
Ranking #8,539 across 21,677 CEC solar panels (top 41.3%; higher than 58.7% of peers), Thornova Solar TS-SB54(410) operates as a modern high-density residential and light-commercial module sitting equal to the 410.0 W Mono-c-Si median. Lower 37.68 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters. With strong 94.3% PTC-to-STC heat retention (#3,231 of 21,677), 20 panels occupy 418 sq ft and offset roughly $2,052/yr at average US rates (or $3,470/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Thornova Solar TS-SB54(410) Fall Across Listed CEC Models?
Plots Thornova Solar TS-SB54(410) at 410.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Thornova Solar TS-SB54(410)?
Benchmarks Thornova Solar TS-SB54(410) on STC wattage, thermal PTC/STC retention, and 21.13 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Thornova Solar TS-SB54(410)?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Thornova Solar TS-SB54(410) by Thornova Solar.
Top 41.3% STC Output
410.0 W STC (+25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.13% Aperture Efficiency
Power density 211.3 W/m2 (1.22 percentage points above 19.91% CEC median). PTC/STC ratio: 94.3% (rank #3,231).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 40.81 V at -10 C (571.3 V string) and 41.7 V at -20 C (14 max).
20 Panels = 8,200 W STC
Occupies 38.8 m2 (418 sq ft) producing 7,732 W PTC; NEC 690.8 OCPD floor is 21.2 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 37.68 * (1 + (-0.237/100) * (-10 - 25)) = 40.81 V | OCPD = 1.56 * 13.59 = 21.2 A
Inputs from CEC Modules.csv for Thornova Solar TS-SB54(410): Voc=37.68 V, beta_Voc=-0.237%/C, Isc=13.59 A, STC=410.0 W, Area=1.94 m2.
Result: 14 panels max on 600 V (571.3 V); 20 panels for 8 kW (418 sq ft).
What Are the Published CEC Specifications for Thornova Solar TS-SB54(410)?
Laboratory test ratings recorded for Thornova Solar TS-SB54(410) (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 410.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 386.6 W (94.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 37.68 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.59 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.84 V / 12.88 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.237 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.13% (1.94 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Mono-c-Si) | Monofacial backsheet |
How Many Thornova Solar TS-SB54(410) Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (418 sq ft at 8 kW), and estimated Year-1 electric bill offset for Thornova Solar TS-SB54(410).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.15 kW | 313 sq ft | $1,539 | $2,603 |
| 8 kW Class | 20 | 8.2 kW | 418 sq ft | $2,052 | $3,470 |
| 10 kW Class | 25 | 10.25 kW | 522 sq ft | $2,565 | $4,338 |
How Many Thornova Solar TS-SB54(410) Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Thornova Solar TS-SB54(410) (beta_Voc -0.237%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 41.7 V | 14 panels | 583.8 V | 23 panels |
| -10 C (14 F) | 40.81 V | 14 panels | 571.3 V | 24 panels |
| 0 C (32 F) | 39.91 V | 15 panels | 598.6 V | 25 panels |
| 25 C (77 F STC) | 37.68 V | 15 panels | 565.2 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to Thornova Solar TS-SB54(410)?
Closest cross-brand CEC competitors to Thornova Solar TS-SB54(410) matched near 410.0 W STC and 37.68 V Voc, led by Aptos Solar Technology LLC DNA-108-MF10-410W-USAptos1.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Aptos Solar Technology LLC DNA-108-MF10-410W-USAptos1 Aptos Solar Technology LLC |
410.0 W | Tie (0 W) | 37.7 V | 21.13% | 94.3% |
| Aptos Solar Technology LLC DNA-108-MF10-410W-USAptos2 Aptos Solar Technology LLC |
410.0 W | Tie (0 W) | 37.7 V | 21.13% | 94.3% |
| Auxin Solar AXN10M410B Auxin Solar |
410.0 W | Tie (0 W) | 37.54 V | 21.64% | 94.0% |
| DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW410M DONGGUAN SUNWORTH SOLAR ENERGY CO LTD |
410.0 W | Tie (0 W) | 37.51 V | 21.58% | 94.5% |
What Are the Design Limits and Best-Fit Uses for Thornova Solar TS-SB54(410)?
Evaluate Thornova Solar TS-SB54(410) (410.0 W STC, 37.68 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Thornova Solar TS-SB54(410) reaches 41.7 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 418 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (418 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Thornova Solar TS-SB54(410) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Thornova Solar TS-SB54(410) 8 kW Residential Fit
Needs 20 modules (418 sq ft) with a 25 A string OCPD, offsetting ~$2,052/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Aptos Solar Technology LLC DNA-108-MF10-410W-USAptos1.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 386.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Thornova Solar TS-SB54(410) by Thornova Solar grounded in CEC test data and NEC 690.7/690.8 limits.
How many Thornova Solar TS-SB54(410) panels fit on a 600 V winter solar string?
At -10 C (14 F), Thornova Solar TS-SB54(410) cold Voc rises from 37.68 V to 40.81 V (beta_Voc -0.237%/C), capping a 600 V string at 14 panels (571.3 V).
How much roof area does an 8 kW array of Thornova Solar TS-SB54(410) need?
An 8 kW DC system uses 20 Thornova Solar TS-SB54(410) modules (8,200 W STC / 7,732 W PTC), covering roughly 418 sq ft and saving ~$2,052/yr at 18.54 c/kWh.
How does Thornova Solar TS-SB54(410) compare against Aptos Solar Technology LLC DNA-108-MF10-410W-USAptos1?
Thornova Solar TS-SB54(410) outputs 410.0 W STC (37.68 V Voc, rank #8,539 of 21,677), while Aptos Solar Technology LLC DNA-108-MF10-410W-USAptos1 delivers 410.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)