Thornova Solar TS-BGT72(600) is a 600.0 W STC (570.2 W PTC) Mono-c-Si solar module ranking #1,320 of 21,677 CEC listings (top 6.7%; higher than 93.3% of peers). It delivers 23.26% efficiency, 52.73 V Voc at 25 C, and 56.75 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 600.0 W
- PTC Wattage
- 570.2 W
- Voc @ 25C
- 52.73 V
- Efficiency
- 23.26%
How Does Thornova Solar TS-BGT72(600) Compare Against Peer CEC Listings?
How Thornova Solar Thornova Solar TS-BGT72(600) handles rooftop heat (570.2 W PTC), 8 kW sizing, and cold winter string voltage.
Thornova Solar builds the Thornova Solar TS-BGT72(600) (Mono-c-Si) as a large-format commercial and ground-mount module delivering 232.6 W/m2 (3.35 percentage points above 19.91% CEC median). Compared against JA Solar JAM72D40-600/MB (600.0 W), this model holds strong 95.0% PTC-to-STC heat retention (#1,106 of 21,677). Higher 52.73 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C), while NEC 690.8 sets a 21.84 A overcurrent floor served by a 25 A breaker.
Where Does Thornova Solar TS-BGT72(600) Fall Across Listed CEC Models?
Where Thornova Solar TS-BGT72(600) (600.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Thornova Solar TS-BGT72(600)?
Percentile placement of Thornova Solar TS-BGT72(600) across power density (232.6 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Thornova Solar TS-BGT72(600)?
Four critical engineering numbers homeowners and solar installers check first when reviewing Thornova Solar TS-BGT72(600) specifications. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
Top 6.7% STC Output
600.0 W STC (+215.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
23.26% Aperture Efficiency
Power density 232.6 W/m2 (3.35 percentage points above 19.91% CEC median). PTC/STC ratio: 95.0% (rank #1,106).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 56.75 V at -10 C (567.5 V string) and 57.9 V at -20 C (10 max).
14 Panels = 8,400 W STC
Occupies 36.1 m2 (389 sq ft) producing 7,983 W PTC; NEC 690.8 OCPD floor is 21.84 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 52.73 * (1 + (-0.218/100) * (-10 - 25)) = 56.75 V | OCPD = 1.56 * 14.0 = 21.84 A
Inputs from CEC Modules.csv for Thornova Solar TS-BGT72(600): Voc=52.73 V, beta_Voc=-0.218%/C, Isc=14.0 A, STC=600.0 W, Area=2.58 m2.
Result: 10 panels max on 600 V (567.5 V); 14 panels for 8 kW (389 sq ft).
What Are the Published CEC Specifications for Thornova Solar TS-BGT72(600)?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Thornova Solar TS-BGT72(600).
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 600.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 570.2 W (95.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 52.73 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 14.0 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 44.76 V / 13.41 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.218 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 23.26% (2.58 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Thornova Solar TS-BGT72(600) Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Thornova Solar TS-BGT72(600) (600.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 10 | 6.0 kW | 278 sq ft | $1,502 | $2,539 |
| 8 kW Class | 14 | 8.4 kW | 389 sq ft | $2,102 | $3,555 |
| 10 kW Class | 17 | 10.2 kW | 472 sq ft | $2,553 | $4,317 |
How Many Thornova Solar TS-BGT72(600) Modules Fit in a Cold-Weather String?
Maximum series module counts for Thornova Solar TS-BGT72(600) from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 57.9 V | 10 panels | 579.0 V | 17 panels |
| -10 C (14 F) | 56.75 V | 10 panels | 567.5 V | 17 panels |
| 0 C (32 F) | 55.6 V | 10 panels | 556.0 V | 17 panels |
| 25 C (77 F STC) | 52.73 V | 11 panels | 580.0 V | 18 panels |
Which Cross-Brand Solar Modules Compare Closest to Thornova Solar TS-BGT72(600)?
Alternative CEC solar modules from competing brands near Thornova Solar TS-BGT72(600) (600.0 W), including JA Solar JAM72D40-600/MB.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| JA Solar JAM72D40-600/MB JA Solar |
600.0 W | Tie (0 W) | 52.79 V | 23.81% | 93.7% |
| JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HD144N-R0-600 JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD |
600.0 W | Tie (0 W) | 52.8 V | 23.26% | 94.7% |
| CSI Solar Co Ltd CS6W-600TB-AG CSI Solar Co Ltd |
600.0 W | Tie (0 W) | 53.0 V | 23.9% | 95.0% |
| CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET CWT600-144TNB10 CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET |
600.0 W | Tie (0 W) | 53.05 V | 23.26% | 95.5% |
What Are the Design Limits and Best-Fit Uses for Thornova Solar TS-BGT72(600)?
Evaluate Thornova Solar TS-BGT72(600) (600.0 W STC, 52.73 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Thornova Solar TS-BGT72(600) reaches 57.9 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 14 panels for an 8 kW build require 389 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Thornova Solar TS-BGT72(600) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Thornova Solar TS-BGT72(600) 8 kW Residential Fit
Needs 14 modules (389 sq ft) with a 25 A string OCPD, offsetting ~$2,102/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare JA Solar JAM72D40-600/MB.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 570.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Thornova Solar TS-BGT72(600) by Thornova Solar grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Thornova Solar TS-BGT72(600)?
Multiplying Thornova Solar TS-BGT72(600)'s 14.0 A short-circuit current by 1.56 equals 21.84 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can Thornova Solar TS-BGT72(600) pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 56.75 V cold Voc at 14 F and handles 14.0 A Isc; string inverters cap Thornova Solar TS-BGT72(600) at 10 panels on 600 V.
Is Thornova Solar TS-BGT72(600) eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Thornova Solar TS-BGT72(600) rely on utility bill offset (~$2,102/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)