Skip to main content
WireAndSun
Calculators
CEC PV Module

Thornova Solar TS-BGT72(600) — CEC Solar Module Specifications

Manufacturer: Thornova Solar Registry: CEC Verified Engineering Specification

Thornova Solar TS-BGT72(600) is a 600.0 W STC (570.2 W PTC) Mono-c-Si solar module ranking #1,320 of 21,677 CEC listings (top 6.7%; higher than 93.3% of peers). It delivers 23.26% efficiency, 52.73 V Voc at 25 C, and 56.75 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
600.0 W
PTC Wattage
570.2 W
Voc @ 25C
52.73 V
Efficiency
23.26%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Thornova Solar TS-BGT72(600) Compare Against Peer CEC Listings?

How Thornova Solar Thornova Solar TS-BGT72(600) handles rooftop heat (570.2 W PTC), 8 kW sizing, and cold winter string voltage.

Thornova Solar builds the Thornova Solar TS-BGT72(600) (Mono-c-Si) as a large-format commercial and ground-mount module delivering 232.6 W/m2 (3.35 percentage points above 19.91% CEC median). Compared against JA Solar JAM72D40-600/MB (600.0 W), this model holds strong 95.0% PTC-to-STC heat retention (#1,106 of 21,677). Higher 52.73 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C), while NEC 690.8 sets a 21.84 A overcurrent floor served by a 25 A breaker.

Where Does Thornova Solar TS-BGT72(600) Fall Across Listed CEC Models?

Where Thornova Solar TS-BGT72(600) (600.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Thornova Solar TS-BGT72(600) (600.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCThornova Solar TS-: 600.0 W

What Dataset Percentiles Define Thornova Solar TS-BGT72(600)?

Percentile placement of Thornova Solar TS-BGT72(600) across power density (232.6 W/m2), thermal retention, and nameplate STC wattage.

Thornova Solar TS-BGT72(600) Engineering BenchmarksPercentile comparison of Thornova Solar TS-BGT72(600) wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage600.0 WPTC/STC Retention95.0%Module Efficiency23.26%

What Do the Dataset Ranks Show for Thornova Solar TS-BGT72(600)?

Four critical engineering numbers homeowners and solar installers check first when reviewing Thornova Solar TS-BGT72(600) specifications. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Rank #1,320 / 21,677

Top 6.7% STC Output

600.0 W STC (+215.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #770

23.26% Aperture Efficiency

Power density 232.6 W/m2 (3.35 percentage points above 19.91% CEC median). PTC/STC ratio: 95.0% (rank #1,106).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 56.75 V at -10 C (567.5 V string) and 57.9 V at -20 C (10 max).

8 kW Reference Array

14 Panels = 8,400 W STC

Occupies 36.1 m2 (389 sq ft) producing 7,983 W PTC; NEC 690.8 OCPD floor is 21.84 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 52.73 * (1 + (-0.218/100) * (-10 - 25)) = 56.75 V | OCPD = 1.56 * 14.0 = 21.84 A

Inputs from CEC Modules.csv for Thornova Solar TS-BGT72(600): Voc=52.73 V, beta_Voc=-0.218%/C, Isc=14.0 A, STC=600.0 W, Area=2.58 m2.

Result: 10 panels max on 600 V (567.5 V); 14 panels for 8 kW (389 sq ft).

What Are the Published CEC Specifications for Thornova Solar TS-BGT72(600)?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Thornova Solar TS-BGT72(600).

Official California Energy Commission (NREL SAM) test parameters for Thornova Solar TS-BGT72(600).
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 600.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 570.2 W (95.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 52.73 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 14.0 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 44.76 V / 13.41 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.218 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 23.26% (2.58 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Bifacial glass-glass

How Many Thornova Solar TS-BGT72(600) Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Thornova Solar TS-BGT72(600) (600.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 10 6.0 kW 278 sq ft $1,502 $2,539
8 kW Class 14 8.4 kW 389 sq ft $2,102 $3,555
10 kW Class 17 10.2 kW 472 sq ft $2,553 $4,317

How Many Thornova Solar TS-BGT72(600) Modules Fit in a Cold-Weather String?

Maximum series module counts for Thornova Solar TS-BGT72(600) from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=52.73V and beta_Voc=-0.218%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 57.9 V 10 panels 579.0 V 17 panels
-10 C (14 F) 56.75 V 10 panels 567.5 V 17 panels
0 C (32 F) 55.6 V 10 panels 556.0 V 17 panels
25 C (77 F STC) 52.73 V 11 panels 580.0 V 18 panels

Which Cross-Brand Solar Modules Compare Closest to Thornova Solar TS-BGT72(600)?

Alternative CEC solar modules from competing brands near Thornova Solar TS-BGT72(600) (600.0 W), including JA Solar JAM72D40-600/MB.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
JA Solar JAM72D40-600/MB
JA Solar
600.0 W Tie (0 W) 52.79 V 23.81% 93.7%
JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HD144N-R0-600
JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD
600.0 W Tie (0 W) 52.8 V 23.26% 94.7%
CSI Solar Co Ltd CS6W-600TB-AG
CSI Solar Co Ltd
600.0 W Tie (0 W) 53.0 V 23.9% 95.0%
CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET CWT600-144TNB10
CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET
600.0 W Tie (0 W) 53.05 V 23.26% 95.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Thornova Solar TS-BGT72(600)?

Evaluate Thornova Solar TS-BGT72(600) (600.0 W STC, 52.73 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Thornova Solar TS-BGT72(600) reaches 57.9 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 14 panels for an 8 kW build require 389 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of Thornova Solar TS-BGT72(600) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Thornova Solar TS-BGT72(600) 8 kW Residential Fit

Needs 14 modules (389 sq ft) with a 25 A string OCPD, offsetting ~$2,102/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare JA Solar JAM72D40-600/MB.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 570.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Thornova Solar TS-BGT72(600) by Thornova Solar grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Thornova Solar TS-BGT72(600)?

Multiplying Thornova Solar TS-BGT72(600)'s 14.0 A short-circuit current by 1.56 equals 21.84 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

Can Thornova Solar TS-BGT72(600) pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 56.75 V cold Voc at 14 F and handles 14.0 A Isc; string inverters cap Thornova Solar TS-BGT72(600) at 10 panels on 600 V.

Is Thornova Solar TS-BGT72(600) eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Thornova Solar TS-BGT72(600) rely on utility bill offset (~$2,102/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.