Thornova Solar TS-BGT72(585) is a 585.0 W STC (555.6 W PTC) Mono-c-Si solar module ranking #1,751 of 21,677 CEC listings (top 8.7%; higher than 91.3% of peers). It delivers 22.67% efficiency, 52.16 V Voc at 25 C, and 56.14 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 585.0 W
- PTC Wattage
- 555.6 W
- Voc @ 25C
- 52.16 V
- Efficiency
- 22.67%
How Does Thornova Solar TS-BGT72(585) Compare Against Peer CEC Listings?
How Thornova Solar Thornova Solar TS-BGT72(585) handles rooftop heat (555.6 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, Thornova Solar TS-BGT72(585) exhibits 13.85 A short-circuit current, requiring a 21.61 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #1,751 of 21,677 (175.0 W above the 410.0 W Mono-c-Si median), this large-format commercial and ground-mount module covers 36.1 m2 for an 8 kW system (18 panels for 10 kW). Higher 52.16 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).
Where Does Thornova Solar TS-BGT72(585) Fall Across Listed CEC Models?
Where Thornova Solar TS-BGT72(585) (585.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Thornova Solar TS-BGT72(585)?
Percentile placement of Thornova Solar TS-BGT72(585) across power density (226.7 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Thornova Solar TS-BGT72(585)?
Four critical engineering numbers homeowners and solar installers check first when reviewing Thornova Solar TS-BGT72(585) specifications. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
Top 8.7% STC Output
585.0 W STC (+200.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
22.67% Aperture Efficiency
Power density 226.7 W/m2 (2.76 percentage points above 19.91% CEC median). PTC/STC ratio: 95.0% (rank #1,106).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 56.14 V at -10 C (561.4 V string) and 57.28 V at -20 C (10 max).
14 Panels = 8,190 W STC
Occupies 36.1 m2 (389 sq ft) producing 7,778 W PTC; NEC 690.8 OCPD floor is 21.61 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 52.16 * (1 + (-0.218/100) * (-10 - 25)) = 56.14 V | OCPD = 1.56 * 13.85 = 21.61 A
Inputs from CEC Modules.csv for Thornova Solar TS-BGT72(585): Voc=52.16 V, beta_Voc=-0.218%/C, Isc=13.85 A, STC=585.0 W, Area=2.58 m2.
Result: 10 panels max on 600 V (561.4 V); 14 panels for 8 kW (389 sq ft).
What Are the Published CEC Specifications for Thornova Solar TS-BGT72(585)?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Thornova Solar TS-BGT72(585).
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 585.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 555.6 W (95.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 52.16 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.85 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 44.22 V / 13.23 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.218 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 22.67% (2.58 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Thornova Solar TS-BGT72(585) Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Thornova Solar TS-BGT72(585) (585.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 11 | 6.43 kW | 305 sq ft | $1,609 | $2,721 |
| 8 kW Class | 14 | 8.19 kW | 389 sq ft | $2,050 | $3,466 |
| 10 kW Class | 18 | 10.53 kW | 500 sq ft | $2,636 | $4,457 |
How Many Thornova Solar TS-BGT72(585) Modules Fit in a Cold-Weather String?
Maximum series module counts for Thornova Solar TS-BGT72(585) from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 57.28 V | 10 panels | 572.8 V | 17 panels |
| -10 C (14 F) | 56.14 V | 10 panels | 561.4 V | 17 panels |
| 0 C (32 F) | 55.0 V | 10 panels | 550.0 V | 18 panels |
| 25 C (77 F STC) | 52.16 V | 11 panels | 573.8 V | 19 panels |
Which Cross-Brand Solar Modules Compare Closest to Thornova Solar TS-BGT72(585)?
Alternative CEC solar modules from competing brands near Thornova Solar TS-BGT72(585) (585.0 W), including CSI Solar Co Ltd CS6W-585TB-AG.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS6W-585TB-AG CSI Solar Co Ltd |
585.0 W | Tie (0 W) | 52.4 V | 23.31% | 95.0% |
| Boviet Solar Technology Co Ltd BVM7612M-585-H-HC-BF Boviet Solar Technology Co Ltd |
585.0 W | Tie (0 W) | 52.61 V | 22.67% | 95.1% |
| Boviet Solar Technology Co Ltd BVM7612M-585-H-HC-BF-DG Boviet Solar Technology Co Ltd |
585.0 W | Tie (0 W) | 52.61 V | 22.67% | 95.1% |
| AMPS Solar AMPS-585N-144SW AMPS Solar |
585.0 W | Tie (0 W) | 52.7 V | 22.85% | 94.9% |
What Are the Design Limits and Best-Fit Uses for Thornova Solar TS-BGT72(585)?
Evaluate Thornova Solar TS-BGT72(585) (585.0 W STC, 52.16 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Thornova Solar TS-BGT72(585) reaches 57.28 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 14 panels for an 8 kW build require 389 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Thornova Solar TS-BGT72(585) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Thornova Solar TS-BGT72(585) 8 kW Residential Fit
Needs 14 modules (389 sq ft) with a 25 A string OCPD, offsetting ~$2,050/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare CSI Solar Co Ltd CS6W-585TB-AG.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 555.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Thornova Solar TS-BGT72(585) by Thornova Solar grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Thornova Solar TS-BGT72(585) PTC wattage (555.6 W) lower than STC (585.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 555.6 W PTC (95.0% retention) across Thornova Solar TS-BGT72(585)'s 2.58 m2 aperture.
Who should skip Thornova Solar TS-BGT72(585) on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 14 Thornova Solar TS-BGT72(585) panels (389 sq ft) leave unusable roof gaps vs. CSI Solar Co Ltd CS6W-585TB-AG.
What is the 1,000 V commercial string limit for Thornova Solar TS-BGT72(585)?
On 1,000 V commercial inverters at -10 C (56.14 V cold Voc), Thornova Solar TS-BGT72(585) fits up to 17 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Thornova Solar TS-BGT72(585).
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)