Thornova Solar TS-BG54(410) — CEC Solar Module Specifications

Manufacturer: Thornova Solar Registry: CEC Verified Engineering Specification

Thornova Solar TS-BG54(410) is a 410.0 W STC (387.2 W PTC) Mono-c-Si solar module ranking #8,539 of 21,677 CEC listings (top 41.3%; higher than 58.7% of peers). It delivers 21.13% efficiency, 37.68 V Voc at 25 C, and 40.91 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
410.0 W
PTC Wattage
387.2 W
Voc @ 25C
37.68 V
Efficiency
21.13%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Thornova Solar TS-BG54(410) Compare Against Peer CEC Listings?

Engineering position of Thornova Solar TS-BG54(410) (410.0 W STC) vs. ASTORIOS Holding Inc ASTR108BDG-410W-US across 5,889 CEC Mono-c-Si solar modules.

Built with 54 Mono-c-Si cells, Thornova Solar TS-BG54(410) pairs strong 94.4% PTC-to-STC heat retention (#2,840 of 21,677) with 37.68 V nominal Voc. An 8 kW residential build (8,200 W DC, 7,744 W PTC) saves ~$2,052/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Peer ASTORIOS Holding Inc ASTR108BDG-410W-US offers a 410.0 W alternative.

Where Does Thornova Solar TS-BG54(410) Fall Across Listed CEC Models?

Plots Thornova Solar TS-BG54(410) at 410.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Thornova Solar TS-BG54(410) (410.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCThornova Solar TS-: 410.0 W

What Dataset Percentiles Define Thornova Solar TS-BG54(410)?

Benchmarks Thornova Solar TS-BG54(410) on STC wattage, thermal PTC/STC retention, and 21.13 aperture conversion efficiency against CEC peers.

Thornova Solar TS-BG54(410) Engineering BenchmarksPercentile comparison of Thornova Solar TS-BG54(410) wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage410.0 WPTC/STC Retention94.4%Module Efficiency21.13%

What Do the Dataset Ranks Show for Thornova Solar TS-BG54(410)?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Thornova Solar TS-BG54(410) by Thornova Solar.

Rank #8,539 / 21,677

Top 41.3% STC Output

410.0 W STC (+25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #5,767

21.13% Aperture Efficiency

Power density 211.3 W/m2 (1.22 percentage points above 19.91% CEC median). PTC/STC ratio: 94.4% (rank #2,840).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.91 V at -10 C (572.7 V string) and 41.83 V at -20 C (14 max).

8 kW Reference Array

20 Panels = 8,200 W STC

Occupies 38.8 m2 (418 sq ft) producing 7,744 W PTC; NEC 690.8 OCPD floor is 21.2 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.68 * (1 + (-0.245/100) * (-10 - 25)) = 40.91 V | OCPD = 1.56 * 13.59 = 21.2 A

Inputs from CEC Modules.csv for Thornova Solar TS-BG54(410): Voc=37.68 V, beta_Voc=-0.245%/C, Isc=13.59 A, STC=410.0 W, Area=1.94 m2.

Result: 14 panels max on 600 V (572.7 V); 20 panels for 8 kW (418 sq ft).

What Are the Published CEC Specifications for Thornova Solar TS-BG54(410)?

Laboratory test ratings recorded for Thornova Solar TS-BG54(410) (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Thornova Solar TS-BG54(410).
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 410.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 387.2 W (94.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.68 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.59 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.84 V / 12.88 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.245 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.13% (1.94 m2) Array roof footprint density
Cell Count & Technology 54 cells (Mono-c-Si) Bifacial glass-glass

How Many Thornova Solar TS-BG54(410) Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (418 sq ft at 8 kW), and estimated Year-1 electric bill offset for Thornova Solar TS-BG54(410).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.15 kW 313 sq ft $1,539 $2,603
8 kW Class 20 8.2 kW 418 sq ft $2,052 $3,470
10 kW Class 25 10.25 kW 522 sq ft $2,565 $4,338

How Many Thornova Solar TS-BG54(410) Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Thornova Solar TS-BG54(410) (beta_Voc -0.245%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=37.68V and beta_Voc=-0.245%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 41.83 V 14 panels 585.6 V 23 panels
-10 C (14 F) 40.91 V 14 panels 572.7 V 24 panels
0 C (32 F) 39.99 V 15 panels 599.9 V 25 panels
25 C (77 F STC) 37.68 V 15 panels 565.2 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to Thornova Solar TS-BG54(410)?

Closest cross-brand CEC competitors to Thornova Solar TS-BG54(410) matched near 410.0 W STC and 37.68 V Voc, led by ASTORIOS Holding Inc ASTR108BDG-410W-US.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
ASTORIOS Holding Inc ASTR108BDG-410W-US
ASTORIOS Holding Inc
410.0 W Tie (0 W) 37.5 V 21.13% 93.0%
AXITEC AC-410MBT/108US
AXITEC
410.0 W Tie (0 W) 37.5 V 21.13% 93.0%
CSI Solar Co Ltd CS6R-410MB
CSI Solar Co Ltd
410.0 W Tie (0 W) 38.0 V 21.69% 94.2%
CSI Solar Co Ltd CS6R-410MB-HL
CSI Solar Co Ltd
410.0 W Tie (0 W) 38.0 V 21.69% 94.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Thornova Solar TS-BG54(410)?

Evaluate Thornova Solar TS-BG54(410) (410.0 W STC, 37.68 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Thornova Solar TS-BG54(410) reaches 41.83 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 418 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (418 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Thornova Solar TS-BG54(410) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Thornova Solar TS-BG54(410) 8 kW Residential Fit

Needs 20 modules (418 sq ft) with a 25 A string OCPD, offsetting ~$2,052/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare ASTORIOS Holding Inc ASTR108BDG-410W-US.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 387.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Thornova Solar TS-BG54(410) by Thornova Solar grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Thornova Solar TS-BG54(410)?

Multiplying Thornova Solar TS-BG54(410)'s 13.59 A short-circuit current by 1.56 equals 21.2 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

Can Thornova Solar TS-BG54(410) pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 40.91 V cold Voc at 14 F and handles 13.59 A Isc; string inverters cap Thornova Solar TS-BG54(410) at 14 panels on 600 V.

Is Thornova Solar TS-BG54(410) eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Thornova Solar TS-BG54(410) rely on utility bill offset (~$2,052/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.