Skip to main content
WireAndSun
Calculators
CEC PV Module

CSI Solar Co Ltd CS6R-410MB-HL — CEC Solar Module Specifications

Manufacturer: CSI Solar Co Ltd Registry: CEC Verified Engineering Specification

CSI Solar Co Ltd CS6R-410MB-HL is a 410.0 W STC (386.1 W PTC) Mono-c-Si solar module ranking #8,539 of 21,677 CEC listings (top 41.3%; higher than 58.7% of peers). It delivers 21.69% efficiency, 38.0 V Voc at 25 C, and 41.42 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
410.0 W
PTC Wattage
386.1 W
Voc @ 25C
38.0 V
Efficiency
21.69%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does CSI Solar Co Ltd CS6R-410MB-HL Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for CSI Solar Co Ltd CS6R-410MB-HL (Mono-c-Si) residential solar systems.

Homeowners evaluating CSI Solar Co Ltd CS6R-410MB-HL need 15 panels for 6 kW or 20 panels (407 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 20 panels (407 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.257%/C) pushes open-circuit voltage to 41.42 V at 14 F and 42.39 V at -4 F. Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes.

Where Does CSI Solar Co Ltd CS6R-410MB-HL Fall Across Listed CEC Models?

Comparison of CSI Solar Co Ltd CS6R-410MB-HL (410.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where CSI Solar Co Ltd CS6R-410MB-HL (410.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCCSI Solar Co Ltd C: 410.0 W

What Dataset Percentiles Define CSI Solar Co Ltd CS6R-410MB-HL?

Relative ranking of CSI Solar Co Ltd CS6R-410MB-HL across nameplate watts, 94.2% PTC thermal ratio, and module aperture efficiency.

CSI Solar Co Ltd CS6R-410MB-HL Engineering BenchmarksPercentile comparison of CSI Solar Co Ltd CS6R-410MB-HL wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage410.0 WPTC/STC Retention94.2%Module Efficiency21.69%

What Do the Dataset Ranks Show for CSI Solar Co Ltd CS6R-410MB-HL?

Summary of CSI Solar Co Ltd CS6R-410MB-HL output rank, 8 kW array size (20 panels), efficiency rating, and 600 V string limit.

Rank #8,539 / 21,677

Top 41.3% STC Output

410.0 W STC (+25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #3,894

21.69% Aperture Efficiency

Power density 216.9 W/m2 (1.78 percentage points above 19.91% CEC median). PTC/STC ratio: 94.2% (rank #3,689).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 41.42 V at -10 C (579.9 V string) and 42.39 V at -20 C (14 max).

8 kW Reference Array

20 Panels = 8,200 W STC

Occupies 37.8 m2 (407 sq ft) producing 7,722 W PTC; NEC 690.8 OCPD floor is 21.17 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 38.0 * (1 + (-0.257/100) * (-10 - 25)) = 41.42 V | OCPD = 1.56 * 13.57 = 21.17 A

Inputs from CEC Modules.csv for CSI Solar Co Ltd CS6R-410MB-HL: Voc=38.0 V, beta_Voc=-0.257%/C, Isc=13.57 A, STC=410.0 W, Area=1.89 m2.

Result: 14 panels max on 600 V (579.9 V); 20 panels for 8 kW (407 sq ft).

What Are the Published CEC Specifications for CSI Solar Co Ltd CS6R-410MB-HL?

Complete CEC test sheet for CSI Solar Co Ltd CS6R-410MB-HL including Isc (13.57 A), Voc (38.0 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for CSI Solar Co Ltd CS6R-410MB-HL.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 410.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 386.1 W (94.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 38.0 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.57 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.8 V / 12.91 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.257 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.69% (1.89 m2) Array roof footprint density
Cell Count & Technology 54 cells (Mono-c-Si) Bifacial glass-glass

How Many CSI Solar Co Ltd CS6R-410MB-HL Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using CSI Solar Co Ltd CS6R-410MB-HL.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.15 kW 305 sq ft $1,539 $2,603
8 kW Class 20 8.2 kW 407 sq ft $2,052 $3,470
10 kW Class 25 10.25 kW 509 sq ft $2,565 $4,338

Which Sibling Wattage & Trim Variants Belong to This CSI Solar Co Ltd Series?

Related CSI Solar Co Ltd power steps and black/silver trims consolidated into this CSI Solar Co Ltd CS6R-410MB-HL series guide.

Sibling CEC listings grouped into the CSI Solar Co Ltd CS6R-410MB-HL wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
CSI Solar Co Ltd CS6R-400MB-HL 400.0 W 376.5 W 37.6 V 31.4 V 21.16%
CSI Solar Co Ltd CS6R-405MB-HL 405.0 W 381.3 W 37.8 V 31.6 V 21.43%
CSI Solar Co Ltd CS6R-410MB-HL 410.0 W 386.1 W 38.0 V 31.8 V 21.69%
CSI Solar Co Ltd CS6R-415MB-HL 415.0 W 391.0 W 38.2 V 32.0 V 21.96%
CSI Solar Co Ltd CS6R-420MB-HL 420.0 W 395.8 W 38.4 V 32.2 V 22.22%

How Many CSI Solar Co Ltd CS6R-410MB-HL Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for CSI Solar Co Ltd CS6R-410MB-HL (38.0 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=38.0V and beta_Voc=-0.257%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 42.39 V 14 panels 593.5 V 23 panels
-10 C (14 F) 41.42 V 14 panels 579.9 V 24 panels
0 C (32 F) 40.44 V 14 panels 566.2 V 24 panels
25 C (77 F STC) 38.0 V 15 panels 570.0 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to CSI Solar Co Ltd CS6R-410MB-HL?

Four comparable CEC modules such as ASTORIOS Holding Inc ASTR108BDG-410W-US (410.0 W) for side-by-side solar quote checks. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
ASTORIOS Holding Inc ASTR108BDG-410W-US
ASTORIOS Holding Inc
410.0 W Tie (0 W) 37.5 V 21.13% 93.0%
AXITEC AC-410MBT/108US
AXITEC
410.0 W Tie (0 W) 37.5 V 21.13% 93.0%
Elin Energy (Sirius PV) ELNSM54M-HC-BF-410
Elin Energy (Sirius PV)
410.0 W Tie (0 W) 37.32 V 21.13% 94.4%
Boviet Solar Technology Co Ltd BVM7609M-415-H-HC-BF
Boviet Solar Technology Co Ltd
415.0 W +5.0 W 38.47 V 19.21% 94.7%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for CSI Solar Co Ltd CS6R-410MB-HL?

Evaluate CSI Solar Co Ltd CS6R-410MB-HL (410.0 W STC, 38.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), CSI Solar Co Ltd CS6R-410MB-HL reaches 42.39 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 407 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (407 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of CSI Solar Co Ltd CS6R-410MB-HL carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

CSI Solar Co Ltd CS6R-410MB-HL 8 kW Residential Fit

Needs 20 modules (407 sq ft) with a 25 A string OCPD, offsetting ~$2,052/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare ASTORIOS Holding Inc ASTR108BDG-410W-US.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 386.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for CSI Solar Co Ltd CS6R-410MB-HL by CSI Solar Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

Why is CSI Solar Co Ltd CS6R-410MB-HL PTC wattage (386.1 W) lower than STC (410.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 386.1 W PTC (94.2% retention) across CSI Solar Co Ltd CS6R-410MB-HL's 1.89 m2 aperture.

Who should skip CSI Solar Co Ltd CS6R-410MB-HL on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 20 CSI Solar Co Ltd CS6R-410MB-HL panels (407 sq ft) leave unusable roof gaps vs. ASTORIOS Holding Inc ASTR108BDG-410W-US.

What is the 1,000 V commercial string limit for CSI Solar Co Ltd CS6R-410MB-HL?

On 1,000 V commercial inverters at -10 C (41.42 V cold Voc), CSI Solar Co Ltd CS6R-410MB-HL fits up to 24 panels per series string.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.