Thornova Solar TS-BBT72(600) is a 600.0 W STC (571.0 W PTC) Mono-c-Si solar module ranking #1,320 of 21,677 CEC listings (top 6.7%; higher than 93.3% of peers). It delivers 23.44% efficiency, 52.66 V Voc at 25 C, and 56.94 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 600.0 W
- PTC Wattage
- 571.0 W
- Voc @ 25C
- 52.66 V
- Efficiency
- 23.44%
How Does Thornova Solar TS-BBT72(600) Compare Against Peer CEC Listings?
Engineering position of Thornova Solar TS-BBT72(600) (600.0 W STC) vs. JA Solar JAM72D40-600/MB across 5,889 CEC Mono-c-Si solar modules.
Built with 72 Mono-c-Si cells, Thornova Solar TS-BBT72(600) pairs strong 95.2% PTC-to-STC heat retention (#399 of 21,677) with 52.66 V nominal Voc. An 8 kW residential build (8,400 W DC, 7,994 W PTC) saves ~$2,102/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Peer JA Solar JAM72D40-600/MB offers a 600.0 W alternative.
Where Does Thornova Solar TS-BBT72(600) Fall Across Listed CEC Models?
Plots Thornova Solar TS-BBT72(600) at 600.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Thornova Solar TS-BBT72(600)?
Benchmarks Thornova Solar TS-BBT72(600) on STC wattage, thermal PTC/STC retention, and 23.44 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Thornova Solar TS-BBT72(600)?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Thornova Solar TS-BBT72(600) by Thornova Solar.
Top 6.7% STC Output
600.0 W STC (+215.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
23.44% Aperture Efficiency
Power density 234.4 W/m2 (3.53 percentage points above 19.91% CEC median). PTC/STC ratio: 95.2% (rank #399).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 56.94 V at -10 C (569.4 V string) and 58.16 V at -20 C (10 max).
14 Panels = 8,400 W STC
Occupies 35.8 m2 (386 sq ft) producing 7,994 W PTC; NEC 690.8 OCPD floor is 21.67 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 52.66 * (1 + (-0.232/100) * (-10 - 25)) = 56.94 V | OCPD = 1.56 * 13.89 = 21.67 A
Inputs from CEC Modules.csv for Thornova Solar TS-BBT72(600): Voc=52.66 V, beta_Voc=-0.232%/C, Isc=13.89 A, STC=600.0 W, Area=2.56 m2.
Result: 10 panels max on 600 V (569.4 V); 14 panels for 8 kW (386 sq ft).
What Are the Published CEC Specifications for Thornova Solar TS-BBT72(600)?
Laboratory test ratings recorded for Thornova Solar TS-BBT72(600) (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 600.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 571.0 W (95.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 52.66 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.89 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 44.97 V / 13.35 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.232 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 23.44% (2.56 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Thornova Solar TS-BBT72(600) Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (386 sq ft at 8 kW), and estimated Year-1 electric bill offset for Thornova Solar TS-BBT72(600).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 10 | 6.0 kW | 276 sq ft | $1,502 | $2,539 |
| 8 kW Class | 14 | 8.4 kW | 386 sq ft | $2,102 | $3,555 |
| 10 kW Class | 17 | 10.2 kW | 468 sq ft | $2,553 | $4,317 |
How Many Thornova Solar TS-BBT72(600) Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Thornova Solar TS-BBT72(600) (beta_Voc -0.232%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 58.16 V | 10 panels | 581.6 V | 17 panels |
| -10 C (14 F) | 56.94 V | 10 panels | 569.4 V | 17 panels |
| 0 C (32 F) | 55.71 V | 10 panels | 557.1 V | 17 panels |
| 25 C (77 F STC) | 52.66 V | 11 panels | 579.3 V | 18 panels |
Which Cross-Brand Solar Modules Compare Closest to Thornova Solar TS-BBT72(600)?
Closest cross-brand CEC competitors to Thornova Solar TS-BBT72(600) matched near 600.0 W STC and 52.66 V Voc, led by JA Solar JAM72D40-600/MB.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| JA Solar JAM72D40-600/MB JA Solar |
600.0 W | Tie (0 W) | 52.79 V | 23.81% | 93.7% |
| JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HD144N-R0-600 JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD |
600.0 W | Tie (0 W) | 52.8 V | 23.26% | 94.7% |
| CSI Solar Co Ltd CS6W-600TB-AG CSI Solar Co Ltd |
600.0 W | Tie (0 W) | 53.0 V | 23.9% | 95.0% |
| CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET CWT600-144TNB10 CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET |
600.0 W | Tie (0 W) | 53.05 V | 23.26% | 95.5% |
What Are the Design Limits and Best-Fit Uses for Thornova Solar TS-BBT72(600)?
Evaluate Thornova Solar TS-BBT72(600) (600.0 W STC, 52.66 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Thornova Solar TS-BBT72(600) reaches 58.16 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 14 panels for an 8 kW build require 386 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Thornova Solar TS-BBT72(600) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Thornova Solar TS-BBT72(600) 8 kW Residential Fit
Needs 14 modules (386 sq ft) with a 25 A string OCPD, offsetting ~$2,102/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare JA Solar JAM72D40-600/MB.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 571.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Thornova Solar TS-BBT72(600) by Thornova Solar grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Thornova Solar TS-BBT72(600)?
Multiplying Thornova Solar TS-BBT72(600)'s 13.89 A short-circuit current by 1.56 equals 21.67 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can Thornova Solar TS-BBT72(600) pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 56.94 V cold Voc at 14 F and handles 13.89 A Isc; string inverters cap Thornova Solar TS-BBT72(600) at 10 panels on 600 V.
Is Thornova Solar TS-BBT72(600) eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Thornova Solar TS-BBT72(600) rely on utility bill offset (~$2,102/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)