Skip to main content
WireAndSun
Calculators
CEC PV Module

Thornova Solar TS-BBT54(425) — CEC Solar Module Specifications

Manufacturer: Thornova Solar Registry: CEC Verified Engineering Specification

Thornova Solar TS-BBT54(425) is a 425.0 W STC (403.2 W PTC) Mono-c-Si solar module ranking #7,622 of 21,677 CEC listings (top 36.5%; higher than 63.5% of peers). It delivers 21.91% efficiency, 38.64 V Voc at 25 C, and 41.68 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
425.0 W
PTC Wattage
403.2 W
Voc @ 25C
38.64 V
Efficiency
21.91%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Thornova Solar TS-BBT54(425) Compare Against Peer CEC Listings?

How Thornova Solar Thornova Solar TS-BBT54(425) handles rooftop heat (403.2 W PTC), 8 kW sizing, and cold winter string voltage.

Thornova Solar builds the Thornova Solar TS-BBT54(425) (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 219.1 W/m2 (2.00 percentage points above 19.91% CEC median). Compared against Boviet Solar Technology Co Ltd BVM7609M-430-H-HC-BF (430.0 W), this model holds strong 94.9% PTC-to-STC heat retention (#1,466 of 21,677). Lower 38.64 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 21.03 A overcurrent floor served by a 25 A breaker.

Where Does Thornova Solar TS-BBT54(425) Fall Across Listed CEC Models?

Where Thornova Solar TS-BBT54(425) (425.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Thornova Solar TS-BBT54(425) (425.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCThornova Solar TS-: 425.0 W

What Dataset Percentiles Define Thornova Solar TS-BBT54(425)?

Percentile placement of Thornova Solar TS-BBT54(425) across power density (219.1 W/m2), thermal retention, and nameplate STC wattage.

Thornova Solar TS-BBT54(425) Engineering BenchmarksPercentile comparison of Thornova Solar TS-BBT54(425) wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage425.0 WPTC/STC Retention94.9%Module Efficiency21.91%

What Do the Dataset Ranks Show for Thornova Solar TS-BBT54(425)?

Four critical engineering numbers homeowners and solar installers check first when reviewing Thornova Solar TS-BBT54(425) specifications. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Rank #7,622 / 21,677

Top 36.5% STC Output

425.0 W STC (+40.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #3,277

21.91% Aperture Efficiency

Power density 219.1 W/m2 (2.00 percentage points above 19.91% CEC median). PTC/STC ratio: 94.9% (rank #1,466).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 41.68 V at -10 C (583.5 V string) and 42.55 V at -20 C (14 max).

8 kW Reference Array

19 Panels = 8,075 W STC

Occupies 36.9 m2 (397 sq ft) producing 7,661 W PTC; NEC 690.8 OCPD floor is 21.03 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 38.64 * (1 + (-0.225/100) * (-10 - 25)) = 41.68 V | OCPD = 1.56 * 13.48 = 21.03 A

Inputs from CEC Modules.csv for Thornova Solar TS-BBT54(425): Voc=38.64 V, beta_Voc=-0.225%/C, Isc=13.48 A, STC=425.0 W, Area=1.94 m2.

Result: 14 panels max on 600 V (583.5 V); 19 panels for 8 kW (397 sq ft).

What Are the Published CEC Specifications for Thornova Solar TS-BBT54(425)?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Thornova Solar TS-BBT54(425).

Official California Energy Commission (NREL SAM) test parameters for Thornova Solar TS-BBT54(425).
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 425.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 403.2 W (94.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 38.64 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.48 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 33.07 V / 12.85 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.225 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.91% (1.94 m2) Array roof footprint density
Cell Count & Technology 54 cells (Mono-c-Si) Bifacial glass-glass

How Many Thornova Solar TS-BBT54(425) Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Thornova Solar TS-BBT54(425) (425.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.38 kW 313 sq ft $1,597 $2,700
8 kW Class 19 8.07 kW 397 sq ft $2,020 $3,415
10 kW Class 24 10.2 kW 501 sq ft $2,553 $4,317

How Many Thornova Solar TS-BBT54(425) Modules Fit in a Cold-Weather String?

Maximum series module counts for Thornova Solar TS-BBT54(425) from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=38.64V and beta_Voc=-0.225%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 42.55 V 14 panels 595.7 V 23 panels
-10 C (14 F) 41.68 V 14 panels 583.5 V 23 panels
0 C (32 F) 40.81 V 14 panels 571.3 V 24 panels
25 C (77 F STC) 38.64 V 15 panels 579.6 V 25 panels

Which Cross-Brand Solar Modules Compare Closest to Thornova Solar TS-BBT54(425)?

Alternative CEC solar modules from competing brands near Thornova Solar TS-BBT54(425) (425.0 W), including Boviet Solar Technology Co Ltd BVM7609M-430-H-HC-BF.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Boviet Solar Technology Co Ltd BVM7609M-430-H-HC-BF
Boviet Solar Technology Co Ltd
430.0 W +5.0 W 39.04 V 19.91% 94.8%
Boviet Solar Technology Co Ltd BVM7609M-430-H-HC-BF-DG
Boviet Solar Technology Co Ltd
430.0 W +5.0 W 39.04 V 19.91% 94.8%
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF
Boviet Solar Technology Co Ltd
425.0 W Tie (0 W) 40.7 V 20.24% 94.4%
Elin Energy (Sirius PV) ELNSM54M-HC-BF-430
Elin Energy (Sirius PV)
430.0 W +5.0 W 37.72 V 22.16% 94.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Thornova Solar TS-BBT54(425)?

Evaluate Thornova Solar TS-BBT54(425) (425.0 W STC, 38.64 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Thornova Solar TS-BBT54(425) reaches 42.55 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 19 panels for an 8 kW build require 397 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (397 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Thornova Solar TS-BBT54(425) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Thornova Solar TS-BBT54(425) 8 kW Residential Fit

Needs 19 modules (397 sq ft) with a 25 A string OCPD, offsetting ~$2,020/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM7609M-430-H-HC-BF.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 403.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Thornova Solar TS-BBT54(425) by Thornova Solar grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Thornova Solar TS-BBT54(425)?

Multiplying Thornova Solar TS-BBT54(425)'s 13.48 A short-circuit current by 1.56 equals 21.03 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

Can Thornova Solar TS-BBT54(425) pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 41.68 V cold Voc at 14 F and handles 13.48 A Isc; string inverters cap Thornova Solar TS-BBT54(425) at 14 panels on 600 V.

Is Thornova Solar TS-BBT54(425) eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Thornova Solar TS-BBT54(425) rely on utility bill offset (~$2,020/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.