Elin Energy (Sirius PV) ELNSM54M-HC-BF-430 is a 430.0 W STC (406.5 W PTC) Mono-c-Si solar module ranking #7,266 of 21,677 CEC listings (top 35.2%; higher than 64.8% of peers). It delivers 22.16% efficiency, 37.72 V Voc at 25 C, and 40.91 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
430.0 W
PTC Wattage
406.5 W
Voc @ 25C
37.72 V
Efficiency
22.16%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Elin Energy (Sirius PV) ELNSM54M-HC-BF-430 Compare Against Peer CEC Listings?

How Elin Energy (Sirius PV) Elin Energy (Sirius PV) ELNSM54M-HC-BF-430 handles rooftop heat (406.5 W PTC), 8 kW sizing, and cold winter string voltage.

Elin Energy (Sirius PV) builds the Elin Energy (Sirius PV) ELNSM54M-HC-BF-430 (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 221.6 W/m2 (2.25 percentage points above 19.91% CEC median). Compared against Boviet Solar Technology Co Ltd BVM7609M-430-H-HC-BF (430.0 W), this model holds strong 94.5% PTC-to-STC heat retention (#2,573 of 21,677). Lower 37.72 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 22.15 A overcurrent floor served by a 25 A breaker.

Where Does Elin Energy (Sirius PV) ELNSM54M-HC-BF-430 Fall Across Listed CEC Models?

Where Elin Energy (Sirius PV) ELNSM54M-HC-BF-430 (430.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Elin Energy (Sirius PV) ELNSM54M-HC-BF-430 (430.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCElin Energy (Siriu: 430.0 W

What Dataset Percentiles Define Elin Energy (Sirius PV) ELNSM54M-HC-BF-430?

Percentile placement of Elin Energy (Sirius PV) ELNSM54M-HC-BF-430 across power density (221.6 W/m2), thermal retention, and nameplate STC wattage.

Elin Energy (Sirius PV) ELNSM54M-HC-BF-430 Engineering BenchmarksPercentile comparison of Elin Energy (Sirius PV) ELNSM54M-HC-BF-430 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage430.0 WPTC/STC Retention94.5%Module Efficiency22.16%

What Do the Dataset Ranks Show for Elin Energy (Sirius PV) ELNSM54M-HC-BF-430?

Four critical engineering numbers homeowners and solar installers check first when reviewing Elin Energy (Sirius PV) ELNSM54M-HC-BF-430 specifications.

Rank #7,266 / 21,677

Top 35.2% STC Output

430.0 W STC (+45.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #2,725

22.16% Aperture Efficiency

Power density 221.6 W/m2 (2.25 percentage points above 19.91% CEC median). PTC/STC ratio: 94.5% (rank #2,573).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.91 V at -10 C (572.7 V string) and 41.83 V at -20 C (14 max).

8 kW Reference Array

19 Panels = 8,170 W STC

Occupies 36.9 m2 (397 sq ft) producing 7,724 W PTC; NEC 690.8 OCPD floor is 22.15 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.72 * (1 + (-0.242/100) * (-10 - 25)) = 40.91 V | OCPD = 1.56 * 14.2 = 22.15 A

Inputs from CEC Modules.csv for Elin Energy (Sirius PV) ELNSM54M-HC-BF-430: Voc=37.72 V, beta_Voc=-0.242%/C, Isc=14.2 A, STC=430.0 W, Area=1.94 m2.

Result: 14 panels max on 600 V (572.7 V); 19 panels for 8 kW (397 sq ft).

What Are the Published CEC Specifications for Elin Energy (Sirius PV) ELNSM54M-HC-BF-430?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Elin Energy (Sirius PV) ELNSM54M-HC-BF-430.

Official California Energy Commission (NREL SAM) test parameters for Elin Energy (Sirius PV) ELNSM54M-HC-BF-430.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 430.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 406.5 W (94.5% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.72 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 14.2 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.52 V / 13.62 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.242 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 22.16% (1.94 m2) Array roof footprint density
Cell Count & Technology 54 cells (Mono-c-Si) Bifacial glass-glass

How Many Elin Energy (Sirius PV) ELNSM54M-HC-BF-430 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Elin Energy (Sirius PV) ELNSM54M-HC-BF-430 (430.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.02 kW 292 sq ft $1,507 $2,548
8 kW Class 19 8.17 kW 397 sq ft $2,045 $3,458
10 kW Class 24 10.32 kW 501 sq ft $2,583 $4,368

Which Sibling Wattage & Trim Variants Belong to This Elin Energy (Sirius PV) Series?

All closely matched Elin Energy (Sirius PV) wattages and cosmetic trims sharing the Elin Energy (Sirius PV) ELNSM54M-HC-BF-430 architecture.

Sibling CEC listings grouped into the Elin Energy (Sirius PV) ELNSM54M-HC-BF-430 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Elin Energy (Sirius PV) ELNSM54M-HC-BF-425 425.0 W 401.6 W 37.62 V 31.4 V 21.91%
Elin Energy (Sirius PV) ELNSM54M-HC-BF-430 430.0 W 406.5 W 37.72 V 31.52 V 22.16%
Elin Energy (Sirius PV) ELNSM54M-HC-BF-435 435.0 W 411.3 W 37.82 V 31.64 V 22.42%

How Many Elin Energy (Sirius PV) ELNSM54M-HC-BF-430 Modules Fit in a Cold-Weather String?

Maximum series module counts for Elin Energy (Sirius PV) ELNSM54M-HC-BF-430 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=37.72V and beta_Voc=-0.242%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 41.83 V 14 panels 585.6 V 23 panels
-10 C (14 F) 40.91 V 14 panels 572.7 V 24 panels
0 C (32 F) 40.0 V 15 panels 600.0 V 25 panels
25 C (77 F STC) 37.72 V 15 panels 565.8 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to Elin Energy (Sirius PV) ELNSM54M-HC-BF-430?

Alternative CEC solar modules from competing brands near Elin Energy (Sirius PV) ELNSM54M-HC-BF-430 (430.0 W), including Boviet Solar Technology Co Ltd BVM7609M-430-H-HC-BF.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Boviet Solar Technology Co Ltd BVM7609M-430-H-HC-BF
Boviet Solar Technology Co Ltd
430.0 W Tie (0 W) 39.04 V 19.91% 94.8%
Boviet Solar Technology Co Ltd BVM7609M-430-H-HC-BF-DG
Boviet Solar Technology Co Ltd
430.0 W Tie (0 W) 39.04 V 19.91% 94.8%
CertainTeed CTTC435HC12-08
CertainTeed
435.0 W +5.0 W 38.5 V 22.31% 94.8%
Aptos Solar Technology LLC DNA-108-BFN10-435W-DG
Aptos Solar Technology LLC
435.0 W +5.0 W 39.0 V 22.42% 94.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Elin Energy (Sirius PV) ELNSM54M-HC-BF-430?

Evaluate Elin Energy (Sirius PV) ELNSM54M-HC-BF-430 (430.0 W STC, 37.72 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Elin Energy (Sirius PV) ELNSM54M-HC-BF-430 reaches 41.83 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 19 panels for an 8 kW build require 397 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (397 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Elin Energy (Sirius PV) ELNSM54M-HC-BF-430 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Elin Energy (Sirius PV) ELNSM54M-HC-BF-430 8 kW Residential Fit

Needs 19 modules (397 sq ft) with a 25 A string OCPD, offsetting ~$2,045/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM7609M-430-H-HC-BF.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 406.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Elin Energy (Sirius PV) ELNSM54M-HC-BF-430 by Elin Energy (Sirius PV) grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Elin Energy (Sirius PV) ELNSM54M-HC-BF-430?

Multiplying Elin Energy (Sirius PV) ELNSM54M-HC-BF-430's 14.2 A short-circuit current by 1.56 equals 22.15 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

Can Elin Energy (Sirius PV) ELNSM54M-HC-BF-430 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 40.91 V cold Voc at 14 F and handles 14.2 A Isc; string inverters cap Elin Energy (Sirius PV) ELNSM54M-HC-BF-430 at 14 panels on 600 V.

Is Elin Energy (Sirius PV) ELNSM54M-HC-BF-430 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Elin Energy (Sirius PV) ELNSM54M-HC-BF-430 rely on utility bill offset (~$2,045/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.