Manufacturer: Thornova Solar Registry: CEC Verified Engineering Specification

Thornova Solar TS-BB60(460) is a 460.0 W STC (434.4 W PTC) Mono-c-Si solar module ranking #5,199 of 21,677 CEC listings (top 25.0%; higher than 75.0% of peers). It delivers 21.5% efficiency, 41.78 V Voc at 25 C, and 45.17 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
460.0 W
PTC Wattage
434.4 W
Voc @ 25C
41.78 V
Efficiency
21.5%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Thornova Solar TS-BB60(460) Compare Against Peer CEC Listings?

How Thornova Solar Thornova Solar TS-BB60(460) handles rooftop heat (434.4 W PTC), 8 kW sizing, and cold winter string voltage.

Thornova Solar builds the Thornova Solar TS-BB60(460) (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 215.0 W/m2 (1.59 percentage points above 19.91% CEC median). Compared against Elin Energy (Sirius PV) ELNSM60M-HC-BF-460 (460.0 W), this model holds strong 94.4% PTC-to-STC heat retention (#2,840 of 21,677). Mid-range 41.78 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F, while NEC 690.8 sets a 21.26 A overcurrent floor served by a 25 A breaker.

Where Does Thornova Solar TS-BB60(460) Fall Across Listed CEC Models?

Where Thornova Solar TS-BB60(460) (460.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Thornova Solar TS-BB60(460) (460.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCThornova Solar TS-: 460.0 W

What Dataset Percentiles Define Thornova Solar TS-BB60(460)?

Percentile placement of Thornova Solar TS-BB60(460) across power density (215.0 W/m2), thermal retention, and nameplate STC wattage.

Thornova Solar TS-BB60(460) Engineering BenchmarksPercentile comparison of Thornova Solar TS-BB60(460) wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage460.0 WPTC/STC Retention94.4%Module Efficiency21.5%

What Do the Dataset Ranks Show for Thornova Solar TS-BB60(460)?

Four critical engineering numbers homeowners and solar installers check first when reviewing Thornova Solar TS-BB60(460) specifications. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Rank #5,199 / 21,677

Top 25.0% STC Output

460.0 W STC (+75.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #4,451

21.5% Aperture Efficiency

Power density 215.0 W/m2 (1.59 percentage points above 19.91% CEC median). PTC/STC ratio: 94.4% (rank #2,840).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 45.17 V at -10 C (587.2 V string) and 46.14 V at -20 C (13 max).

8 kW Reference Array

18 Panels = 8,280 W STC

Occupies 38.5 m2 (415 sq ft) producing 7,819 W PTC; NEC 690.8 OCPD floor is 21.26 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 41.78 * (1 + (-0.232/100) * (-10 - 25)) = 45.17 V | OCPD = 1.56 * 13.63 = 21.26 A

Inputs from CEC Modules.csv for Thornova Solar TS-BB60(460): Voc=41.78 V, beta_Voc=-0.232%/C, Isc=13.63 A, STC=460.0 W, Area=2.14 m2.

Result: 13 panels max on 600 V (587.2 V); 18 panels for 8 kW (415 sq ft).

What Are the Published CEC Specifications for Thornova Solar TS-BB60(460)?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Thornova Solar TS-BB60(460).

Official California Energy Commission (NREL SAM) test parameters for Thornova Solar TS-BB60(460).
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 460.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 434.4 W (94.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 41.78 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.63 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 34.89 V / 13.19 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.232 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.5% (2.14 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Bifacial glass-glass

How Many Thornova Solar TS-BB60(460) Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Thornova Solar TS-BB60(460) (460.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.44 kW 322 sq ft $1,612 $2,726
8 kW Class 18 8.28 kW 415 sq ft $2,072 $3,504
10 kW Class 22 10.12 kW 507 sq ft $2,533 $4,283

How Many Thornova Solar TS-BB60(460) Modules Fit in a Cold-Weather String?

Maximum series module counts for Thornova Solar TS-BB60(460) from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=41.78V and beta_Voc=-0.232%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 46.14 V 13 panels 599.8 V 21 panels
-10 C (14 F) 45.17 V 13 panels 587.2 V 22 panels
0 C (32 F) 44.2 V 13 panels 574.6 V 22 panels
25 C (77 F STC) 41.78 V 14 panels 584.9 V 23 panels

Which Cross-Brand Solar Modules Compare Closest to Thornova Solar TS-BB60(460)?

Alternative CEC solar modules from competing brands near Thornova Solar TS-BB60(460) (460.0 W), including Elin Energy (Sirius PV) ELNSM60M-HC-BF-460.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Elin Energy (Sirius PV) ELNSM60M-HC-BF-460
Elin Energy (Sirius PV)
460.0 W Tie (0 W) 41.52 V 21.4% 94.4%
Boviet Solar Technology Co Ltd BVM7610M-460-H-HC-BF-DG
Boviet Solar Technology Co Ltd
460.0 W Tie (0 W) 42.49 V 21.9% 94.2%
Aptos Solar Technology LLC DNA-120-BF10-455W-USAptos2
Aptos Solar Technology LLC
455.0 W -5.0 W 41.7 V 21.26% 94.4%
Aptos Solar Technology LLC DNA-120-BF10-455W-USAptos1
Aptos Solar Technology LLC
455.0 W -5.0 W 41.65 V 21.26% 94.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Thornova Solar TS-BB60(460)?

Evaluate Thornova Solar TS-BB60(460) (460.0 W STC, 41.78 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Thornova Solar TS-BB60(460) reaches 46.14 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 18 panels for an 8 kW build require 415 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (415 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Thornova Solar TS-BB60(460) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Thornova Solar TS-BB60(460) 8 kW Residential Fit

Needs 18 modules (415 sq ft) with a 25 A string OCPD, offsetting ~$2,072/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Elin Energy (Sirius PV) ELNSM60M-HC-BF-460.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 434.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Thornova Solar TS-BB60(460) by Thornova Solar grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Thornova Solar TS-BB60(460)?

Multiplying Thornova Solar TS-BB60(460)'s 13.63 A short-circuit current by 1.56 equals 21.26 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

Can Thornova Solar TS-BB60(460) pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 45.17 V cold Voc at 14 F and handles 13.63 A Isc; string inverters cap Thornova Solar TS-BB60(460) at 13 panels on 600 V.

Is Thornova Solar TS-BB60(460) eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Thornova Solar TS-BB60(460) rely on utility bill offset (~$2,072/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.