Thornova Solar TS-BB54(410) is a 410.0 W STC (381.7 W PTC) Mono-c-Si solar module ranking #8,539 of 21,677 CEC listings (top 41.3%; higher than 58.7% of peers). It delivers 21.03% efficiency, 37.7 V Voc at 25 C, and 41.13 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 410.0 W
- PTC Wattage
- 381.7 W
- Voc @ 25C
- 37.7 V
- Efficiency
- 21.03%
How Does Thornova Solar TS-BB54(410) Compare Against Peer CEC Listings?
Solar engineering breakdown for Thornova Solar TS-BB54(410): PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from Thornova Solar and peers, Thornova Solar TS-BB54(410) stands equal to the 410.0 W Mono-c-Si median and strong 93.1% PTC-to-STC heat retention (#9,420 of 21,677). Sizing 6 kW (15 panels) to 10 kW (25 panels) yields $1,539-$2,565/yr in baseline US bill offset. Lower 37.7 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.
Where Does Thornova Solar TS-BB54(410) Fall Across Listed CEC Models?
Distribution marker showing Thornova Solar TS-BB54(410) (410.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Thornova Solar TS-BB54(410)?
Dataset percentiles tracking Thornova Solar TS-BB54(410) power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Thornova Solar TS-BB54(410)?
Benchmark highlights for Thornova Solar TS-BB54(410) covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 41.3% STC Output
410.0 W STC (+25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.03% Aperture Efficiency
Power density 210.3 W/m2 (1.12 percentage points above 19.91% CEC median). PTC/STC ratio: 93.1% (rank #9,420).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 41.13 V at -10 C (575.8 V string) and 42.11 V at -20 C (14 max).
20 Panels = 8,200 W STC
Occupies 39.0 m2 (420 sq ft) producing 7,634 W PTC; NEC 690.8 OCPD floor is 21.2 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 37.7 * (1 + (-0.26/100) * (-10 - 25)) = 41.13 V | OCPD = 1.56 * 13.59 = 21.2 A
Inputs from CEC Modules.csv for Thornova Solar TS-BB54(410): Voc=37.7 V, beta_Voc=-0.26%/C, Isc=13.59 A, STC=410.0 W, Area=1.95 m2.
Result: 14 panels max on 600 V (575.8 V); 20 panels for 8 kW (420 sq ft).
What Are the Published CEC Specifications for Thornova Solar TS-BB54(410)?
Official CEC datasheet figures for Thornova Solar TS-BB54(410) (Mono-c-Si) used in utility interconnection and permit reviews. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 410.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 381.7 W (93.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 37.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.59 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.8 V / 12.88 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.26 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.03% (1.95 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Thornova Solar TS-BB54(410) Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Thornova Solar TS-BB54(410) modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.15 kW | 315 sq ft | $1,539 | $2,603 |
| 8 kW Class | 20 | 8.2 kW | 420 sq ft | $2,052 | $3,470 |
| 10 kW Class | 25 | 10.25 kW | 525 sq ft | $2,565 | $4,338 |
How Many Thornova Solar TS-BB54(410) Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Thornova Solar TS-BB54(410) (41.13 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 42.11 V | 14 panels | 589.5 V | 23 panels |
| -10 C (14 F) | 41.13 V | 14 panels | 575.8 V | 24 panels |
| 0 C (32 F) | 40.15 V | 14 panels | 562.1 V | 24 panels |
| 25 C (77 F STC) | 37.7 V | 15 panels | 565.5 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to Thornova Solar TS-BB54(410)?
Competing CEC solar panels closest to Thornova Solar TS-BB54(410) in nameplate wattage and Voc, starting with ASTORIOS Holding Inc ASTR108BDG-410W-US.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| ASTORIOS Holding Inc ASTR108BDG-410W-US ASTORIOS Holding Inc |
410.0 W | Tie (0 W) | 37.5 V | 21.13% | 93.0% |
| AXITEC AC-410MBT/108US AXITEC |
410.0 W | Tie (0 W) | 37.5 V | 21.13% | 93.0% |
| CSI Solar Co Ltd CS6R-410MB CSI Solar Co Ltd |
410.0 W | Tie (0 W) | 38.0 V | 21.69% | 94.2% |
| CSI Solar Co Ltd CS6R-410MB-HL CSI Solar Co Ltd |
410.0 W | Tie (0 W) | 38.0 V | 21.69% | 94.2% |
What Are the Design Limits and Best-Fit Uses for Thornova Solar TS-BB54(410)?
Evaluate Thornova Solar TS-BB54(410) (410.0 W STC, 37.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Thornova Solar TS-BB54(410) reaches 42.11 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 420 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (420 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Thornova Solar TS-BB54(410) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Thornova Solar TS-BB54(410) 8 kW Residential Fit
Needs 20 modules (420 sq ft) with a 25 A string OCPD, offsetting ~$2,052/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare ASTORIOS Holding Inc ASTR108BDG-410W-US.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 381.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Thornova Solar TS-BB54(410) by Thornova Solar grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Thornova Solar TS-BB54(410)?
Multiplying Thornova Solar TS-BB54(410)'s 13.59 A short-circuit current by 1.56 equals 21.2 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can Thornova Solar TS-BB54(410) pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 41.13 V cold Voc at 14 F and handles 13.59 A Isc; string inverters cap Thornova Solar TS-BB54(410) at 14 panels on 600 V.
Is Thornova Solar TS-BB54(410) eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Thornova Solar TS-BB54(410) rely on utility bill offset (~$2,052/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)