Skip to main content
WireAndSun
Calculators
CEC PV Module

Suntech Power STP310-24/Ve — CEC Solar Module Specifications

Manufacturer: Suntech Power Registry: CEC Verified Engineering Specification

Suntech Power STP310-24/Ve is a 310.0 W STC (281.2 W PTC) Multi-c-Si solar module ranking #15,760 of 21,677 CEC listings (below all-CEC median; higher than 25.6% of peers). It delivers 15.98% efficiency, 45.2 V Voc at 25 C, and 51.97 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
310.0 W
PTC Wattage
281.2 W
Voc @ 25C
45.2 V
Efficiency
15.98%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Suntech Power STP310-24/Ve Compare Against Peer CEC Listings?

Solar engineering breakdown for Suntech Power STP310-24/Ve: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 1,407 Multi-c-Si listings from Suntech Power and peers, Suntech Power STP310-24/Ve stands 31.2 W above the 278.8 W Multi-c-Si median and typical 90.7% PTC-to-STC thermal output (281.2 W real-world rating). Sizing 6 kW (20 panels) to 10 kW (33 panels) yields $1,552-$2,560/yr in baseline US bill offset. Mid-range 45.2 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F.

Where Does Suntech Power STP310-24/Ve Fall Across Listed CEC Models?

Distribution marker showing Suntech Power STP310-24/Ve (310.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Suntech Power STP310-24/Ve (310.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSuntech Power STP3: 310.0 W

What Dataset Percentiles Define Suntech Power STP310-24/Ve?

Dataset percentiles tracking Suntech Power STP310-24/Ve power output, thermal retention ratio, and aperture efficiency against 21,677 models.

Suntech Power STP310-24/Ve Engineering BenchmarksPercentile comparison of Suntech Power STP310-24/Ve wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage310.0 WPTC/STC Retention90.7%Module Efficiency15.98%

What Do the Dataset Ranks Show for Suntech Power STP310-24/Ve?

Benchmark highlights for Suntech Power STP310-24/Ve covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #15,760 / 21,677

310.0 W STC · Higher Than 25.6%

310.0 W STC (-75.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #18,143

15.98% Aperture Efficiency

Power density 159.8 W/m2 (3.93 percentage points below 19.91% CEC median). PTC/STC ratio: 90.7% (rank #17,330).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 51.97 V at -10 C (571.7 V string) and 53.91 V at -20 C (11 max).

8 kW Reference Array

26 Panels = 8,060 W STC

Occupies 50.4 m2 (543 sq ft) producing 7,311 W PTC; NEC 690.8 OCPD floor is 13.9 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.2 * (1 + (-0.428/100) * (-10 - 25)) = 51.97 V | OCPD = 1.56 * 8.91 = 13.9 A

Inputs from CEC Modules.csv for Suntech Power STP310-24/Ve: Voc=45.2 V, beta_Voc=-0.428%/C, Isc=8.91 A, STC=310.0 W, Area=1.94 m2.

Result: 11 panels max on 600 V (571.7 V); 26 panels for 8 kW (543 sq ft).

What Are the Published CEC Specifications for Suntech Power STP310-24/Ve?

Official CEC datasheet figures for Suntech Power STP310-24/Ve (Multi-c-Si) used in utility interconnection and permit reviews. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Official California Energy Commission (NREL SAM) test parameters for Suntech Power STP310-24/Ve.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 310.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 281.2 W (90.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 45.2 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.91 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 37.1 V / 8.36 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.428 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 15.98% (1.94 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many Suntech Power STP310-24/Ve Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Suntech Power STP310-24/Ve modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 20 6.2 kW 418 sq ft $1,552 $2,624
8 kW Class 26 8.06 kW 543 sq ft $2,017 $3,411
10 kW Class 33 10.23 kW 689 sq ft $2,560 $4,330

Which Sibling Wattage & Trim Variants Belong to This Suntech Power Series?

Consolidated Suntech Power wattage variants sharing the Suntech Power STP310-24/Ve mechanical and cell layout. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Sibling CEC listings grouped into the Suntech Power STP310-24/Ve wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Suntech Power STP300-24/Ve 300.0 W 271.9 W 45.0 V 36.9 V 15.46%
Suntech Power STP305-24/Ve 305.0 W 276.5 W 45.1 V 37.0 V 15.72%
Suntech Power STP310-24/Ve 310.0 W 281.2 W 45.2 V 37.1 V 15.98%
Suntech Power STP315-24/Ve 315.0 W 285.8 W 45.5 V 36.6 V 16.23%
Suntech Power STP320-24/Ve 320.0 W 290.5 W 45.6 V 36.7 V 16.49%

How Many Suntech Power STP310-24/Ve Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Suntech Power STP310-24/Ve (51.97 V at 14 F).

Computed from Voc=45.2V and beta_Voc=-0.428%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 53.91 V 11 panels 593.0 V 18 panels
-10 C (14 F) 51.97 V 11 panels 571.7 V 19 panels
0 C (32 F) 50.04 V 11 panels 550.4 V 19 panels
25 C (77 F STC) 45.2 V 13 panels 587.6 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to Suntech Power STP310-24/Ve?

Competing CEC solar panels closest to Suntech Power STP310-24/Ve in nameplate wattage and Voc, starting with Advance Power API-P310.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Advance Power API-P310
Advance Power
310.0 W Tie (0 W) 45.22 V 15.89% 89.5%
Auxin Solar AXN6P612T310
Auxin Solar
310.0 W Tie (0 W) 45.22 V 15.89% 89.5%
Centrosolar America DP72 310
Centrosolar America
310.0 W Tie (0 W) 45.18 V 15.94% 90.2%
AXITEC AC-310P/156-72S
AXITEC
310.0 W Tie (0 W) 45.05 V 16.01% 89.0%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Suntech Power STP310-24/Ve?

Evaluate Suntech Power STP310-24/Ve (310.0 W STC, 45.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Suntech Power STP310-24/Ve reaches 53.91 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 26 panels for an 8 kW build require 543 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (543 sq ft).
  • 2026 tax credit baseline: cash residential installs of Suntech Power STP310-24/Ve carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Suntech Power STP310-24/Ve 8 kW Residential Fit

Needs 26 modules (543 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Advance Power API-P310.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 281.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Suntech Power STP310-24/Ve by Suntech Power grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Suntech Power STP310-24/Ve?

Multiplying Suntech Power STP310-24/Ve's 8.91 A short-circuit current by 1.56 equals 13.9 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Suntech Power STP310-24/Ve pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 51.97 V cold Voc at 14 F and handles 8.91 A Isc; string inverters cap Suntech Power STP310-24/Ve at 11 panels on 600 V.

Is Suntech Power STP310-24/Ve eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Suntech Power STP310-24/Ve rely on utility bill offset (~$2,017/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.