Suntech Power STP315-24/Vem is a 315.0 W STC (288.2 W PTC) Multi-c-Si solar module ranking #15,387 of 21,677 CEC listings (below all-CEC median; higher than 27.3% of peers). It delivers 16.23% efficiency, 45.1 V Voc at 25 C, and 50.32 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 315.0 W
- PTC Wattage
- 288.2 W
- Voc @ 25C
- 45.1 V
- Efficiency
- 16.23%
How Does Suntech Power STP315-24/Vem Compare Against Peer CEC Listings?
How Suntech Power Suntech Power STP315-24/Vem handles rooftop heat (288.2 W PTC), 8 kW sizing, and cold winter string voltage.
Suntech Power builds the Suntech Power STP315-24/Vem (Multi-c-Si) as a compact residential or specialty off-grid module delivering 162.4 W/m2 (3.68 percentage points below 19.91% CEC median). Compared against CSI Solar Co Ltd CS6U-315P (315.0 W), this model holds strong 91.5% PTC-to-STC heat retention (#15,584 of 21,677). Mid-range 45.1 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, while NEC 690.8 sets a 14.07 A overcurrent floor served by a 15 A breaker.
Where Does Suntech Power STP315-24/Vem Fall Across Listed CEC Models?
Where Suntech Power STP315-24/Vem (315.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Suntech Power STP315-24/Vem?
Percentile placement of Suntech Power STP315-24/Vem across power density (162.4 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Suntech Power STP315-24/Vem?
Four critical engineering numbers homeowners and solar installers check first when reviewing Suntech Power STP315-24/Vem specifications. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
315.0 W STC · Higher Than 27.3%
315.0 W STC (-70.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
16.23% Aperture Efficiency
Power density 162.4 W/m2 (3.68 percentage points below 19.91% CEC median). PTC/STC ratio: 91.5% (rank #15,584).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 50.32 V at -10 C (553.5 V string) and 51.82 V at -20 C (11 max).
26 Panels = 8,190 W STC
Occupies 50.4 m2 (543 sq ft) producing 7,493 W PTC; NEC 690.8 OCPD floor is 14.07 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 45.1 * (1 + (-0.331/100) * (-10 - 25)) = 50.32 V | OCPD = 1.56 * 9.02 = 14.07 A
Inputs from CEC Modules.csv for Suntech Power STP315-24/Vem: Voc=45.1 V, beta_Voc=-0.331%/C, Isc=9.02 A, STC=315.0 W, Area=1.94 m2.
Result: 11 panels max on 600 V (553.5 V); 26 panels for 8 kW (543 sq ft).
What Are the Published CEC Specifications for Suntech Power STP315-24/Vem?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Suntech Power STP315-24/Vem.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 315.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 288.2 W (91.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 45.1 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.02 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 36.8 V / 8.56 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.331 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 16.23% (1.94 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Multi-c-Si) | Monofacial backsheet |
How Many Suntech Power STP315-24/Vem Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Suntech Power STP315-24/Vem (315.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 20 | 6.3 kW | 418 sq ft | $1,577 | $2,666 |
| 8 kW Class | 26 | 8.19 kW | 543 sq ft | $2,050 | $3,466 |
| 10 kW Class | 32 | 10.08 kW | 668 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This Suntech Power Series?
All closely matched Suntech Power wattages and cosmetic trims sharing the Suntech Power STP315-24/Vem architecture. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Suntech Power STP305-24/Vem | 305.0 W | 278.8 W | 44.7 V | 36.2 V | 15.72% |
| Suntech Power STP310-24/Vem | 310.0 W | 283.5 W | 44.9 V | 36.5 V | 15.98% |
| Suntech Power STP315-24/Vem | 315.0 W | 288.2 W | 45.1 V | 36.8 V | 16.23% |
| Suntech Power STP320-24/Vem | 320.0 W | 292.9 W | 45.6 V | 37.1 V | 16.49% |
How Many Suntech Power STP315-24/Vem Modules Fit in a Cold-Weather String?
Maximum series module counts for Suntech Power STP315-24/Vem from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 51.82 V | 11 panels | 570.0 V | 19 panels |
| -10 C (14 F) | 50.32 V | 11 panels | 553.5 V | 19 panels |
| 0 C (32 F) | 48.83 V | 12 panels | 586.0 V | 20 panels |
| 25 C (77 F STC) | 45.1 V | 13 panels | 586.3 V | 22 panels |
Which Cross-Brand Solar Modules Compare Closest to Suntech Power STP315-24/Vem?
Alternative CEC solar modules from competing brands near Suntech Power STP315-24/Vem (315.0 W), including CSI Solar Co Ltd CS6U-315P.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS6U-315P CSI Solar Co Ltd |
315.0 W | Tie (0 W) | 45.1 V | 18.1% | 92.3% |
| CSI Solar Co Ltd CS3U-315P-AG CSI Solar Co Ltd |
315.0 W | Tie (0 W) | 44.9 V | 16.41% | 92.1% |
| GCL System Integration Technology Co Ltd GCL-P6/72315 GCL System Integration Technology Co Ltd |
315.0 W | Tie (0 W) | 45.6 V | 16.23% | 90.5% |
| Centrosolar America EP72 315BW Centrosolar America |
315.0 W | Tie (0 W) | 45.75 V | 16.38% | 91.2% |
What Are the Design Limits and Best-Fit Uses for Suntech Power STP315-24/Vem?
Evaluate Suntech Power STP315-24/Vem (315.0 W STC, 45.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Suntech Power STP315-24/Vem reaches 51.82 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 26 panels for an 8 kW build require 543 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (543 sq ft).
- 2026 tax credit baseline: cash residential installs of Suntech Power STP315-24/Vem carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Suntech Power STP315-24/Vem 8 kW Residential Fit
Needs 26 modules (543 sq ft) with a 15 A string OCPD, offsetting ~$2,050/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare CSI Solar Co Ltd CS6U-315P.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 288.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Suntech Power STP315-24/Vem by Suntech Power grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Suntech Power STP315-24/Vem?
Multiplying Suntech Power STP315-24/Vem's 9.02 A short-circuit current by 1.56 equals 14.07 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can Suntech Power STP315-24/Vem pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 50.32 V cold Voc at 14 F and handles 9.02 A Isc; string inverters cap Suntech Power STP315-24/Vem at 11 panels on 600 V.
Is Suntech Power STP315-24/Vem eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Suntech Power STP315-24/Vem rely on utility bill offset (~$2,050/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)