Suntech Power STP270-24/Ve is a 270.0 W STC (244.7 W PTC) Multi-c-Si solar module ranking #18,572 of 21,677 CEC listings (below all-CEC median; higher than 12.9% of peers). It delivers 13.92% efficiency, 44.5 V Voc at 25 C, and 49.37 V cold Voc at -10 C (12 panels max per 600 V string).
- STC Wattage
- 270.0 W
- PTC Wattage
- 244.7 W
- Voc @ 25C
- 44.5 V
- Efficiency
- 13.92%
How Does Suntech Power STP270-24/Ve Compare Against Peer CEC Listings?
Engineering position of Suntech Power STP270-24/Ve (270.0 W STC) vs. Advance Power API-M270 across 1,407 CEC Multi-c-Si solar modules.
Built with 72 Multi-c-Si cells, Suntech Power STP270-24/Ve pairs typical 90.6% PTC-to-STC thermal output (244.7 W real-world rating) with 44.5 V nominal Voc. An 8 kW residential build (8,100 W DC, 7,341 W PTC) saves ~$2,027/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Advance Power API-M270 offers a 270.0 W alternative.
Where Does Suntech Power STP270-24/Ve Fall Across Listed CEC Models?
Plots Suntech Power STP270-24/Ve at 270.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Suntech Power STP270-24/Ve?
Benchmarks Suntech Power STP270-24/Ve on STC wattage, thermal PTC/STC retention, and 13.92 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Suntech Power STP270-24/Ve?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Suntech Power STP270-24/Ve by Suntech Power.
270.0 W STC · Higher Than 12.9%
270.0 W STC (-115.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
13.92% Aperture Efficiency
Power density 139.2 W/m2 (5.99 percentage points below 19.91% CEC median). PTC/STC ratio: 90.6% (rank #17,534).
12 Panels Max @ -10 C (600 V)
Cold Voc reaches 49.37 V at -10 C (592.4 V string) and 50.77 V at -20 C (11 max).
30 Panels = 8,100 W STC
Occupies 58.2 m2 (626 sq ft) producing 7,341 W PTC; NEC 690.8 OCPD floor is 12.79 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 44.5 * (1 + (-0.313/100) * (-10 - 25)) = 49.37 V | OCPD = 1.56 * 8.2 = 12.79 A
Inputs from CEC Modules.csv for Suntech Power STP270-24/Ve: Voc=44.5 V, beta_Voc=-0.313%/C, Isc=8.2 A, STC=270.0 W, Area=1.94 m2.
Result: 12 panels max on 600 V (592.4 V); 30 panels for 8 kW (626 sq ft).
What Are the Published CEC Specifications for Suntech Power STP270-24/Ve?
Laboratory test ratings recorded for Suntech Power STP270-24/Ve (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 270.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 244.7 W (90.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 44.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.2 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 35.0 V / 7.71 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.313 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 13.92% (1.94 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Multi-c-Si) | Monofacial backsheet |
How Many Suntech Power STP270-24/Ve Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (626 sq ft at 8 kW), and estimated Year-1 electric bill offset for Suntech Power STP270-24/Ve.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 23 | 6.21 kW | 480 sq ft | $1,554 | $2,628 |
| 8 kW Class | 30 | 8.1 kW | 626 sq ft | $2,027 | $3,428 |
| 10 kW Class | 38 | 10.26 kW | 794 sq ft | $2,568 | $4,342 |
Which Sibling Wattage & Trim Variants Belong to This Suntech Power Series?
Sibling wattage bins and frame colors grouped with Suntech Power STP270-24/Ve under Suntech Power to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Suntech Power STP260-24/Ve | 260.0 W | 235.4 W | 44.0 V | 34.8 V | 13.4% |
| Suntech Power STP270-24/Ve | 270.0 W | 244.7 W | 44.5 V | 35.0 V | 13.92% |
How Many Suntech Power STP270-24/Ve Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Suntech Power STP270-24/Ve (beta_Voc -0.313%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 50.77 V | 11 panels | 558.5 V | 19 panels |
| -10 C (14 F) | 49.37 V | 12 panels | 592.4 V | 20 panels |
| 0 C (32 F) | 47.98 V | 12 panels | 575.8 V | 20 panels |
| 25 C (77 F STC) | 44.5 V | 13 panels | 578.5 V | 22 panels |
Which Cross-Brand Solar Modules Compare Closest to Suntech Power STP270-24/Ve?
Closest cross-brand CEC competitors to Suntech Power STP270-24/Ve matched near 270.0 W STC and 44.5 V Voc, led by Advance Power API-M270.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Advance Power API-M270 Advance Power |
270.0 W | Tie (0 W) | 44.64 V | 13.84% | 89.0% |
| Auxin Solar AXN6M612T270 Auxin Solar |
270.0 W | Tie (0 W) | 44.64 V | 13.84% | 89.0% |
| AXITEC AC-270P/156-72S AXITEC |
270.0 W | Tie (0 W) | 44.18 V | 13.94% | 89.9% |
| Centrosolar America DP72 270 Centrosolar America |
270.0 W | Tie (0 W) | 43.85 V | 13.89% | 88.4% |
What Are the Design Limits and Best-Fit Uses for Suntech Power STP270-24/Ve?
Evaluate Suntech Power STP270-24/Ve (270.0 W STC, 44.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Suntech Power STP270-24/Ve reaches 50.77 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 30 panels for an 8 kW build require 626 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (626 sq ft).
- 2026 tax credit baseline: cash residential installs of Suntech Power STP270-24/Ve carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Suntech Power STP270-24/Ve 8 kW Residential Fit
Needs 30 modules (626 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare Advance Power API-M270.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 244.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Suntech Power STP270-24/Ve by Suntech Power grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Suntech Power STP270-24/Ve?
Multiplying Suntech Power STP270-24/Ve's 8.2 A short-circuit current by 1.56 equals 12.79 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can Suntech Power STP270-24/Ve pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 49.37 V cold Voc at 14 F and handles 8.2 A Isc; string inverters cap Suntech Power STP270-24/Ve at 12 panels on 600 V.
Is Suntech Power STP270-24/Ve eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Suntech Power STP270-24/Ve rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)