Auxin Solar AXN6M612T270 is a 270.0 W STC (240.3 W PTC) Mono-c-Si solar module ranking #18,572 of 21,677 CEC listings (below all-CEC median; higher than 12.9% of peers). It delivers 13.84% efficiency, 44.64 V Voc at 25 C, and 49.7 V cold Voc at -10 C (12 panels max per 600 V string).
- STC Wattage
- 270.0 W
- PTC Wattage
- 240.3 W
- Voc @ 25C
- 44.64 V
- Efficiency
- 13.84%
How Does Auxin Solar AXN6M612T270 Compare Against Peer CEC Listings?
Engineering position of Auxin Solar AXN6M612T270 (270.0 W STC) vs. Advance Power API-M270 across 5,889 CEC Mono-c-Si solar modules.
Ranking #18,572 across 21,677 CEC solar panels (below all-CEC median; higher than 12.9% of peers), Auxin Solar AXN6M612T270 operates as a compact residential or specialty off-grid module sitting 140.0 W below the 410.0 W Mono-c-Si median. Mid-range 44.64 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F. With typical 89.0% PTC-to-STC thermal output (240.3 W real-world rating), 30 panels occupy 630 sq ft and offset roughly $2,027/yr at average US rates (or $3,428/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Auxin Solar AXN6M612T270 Fall Across Listed CEC Models?
Plots Auxin Solar AXN6M612T270 at 270.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Auxin Solar AXN6M612T270?
Benchmarks Auxin Solar AXN6M612T270 on STC wattage, thermal PTC/STC retention, and 13.84 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Auxin Solar AXN6M612T270?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Auxin Solar AXN6M612T270 by Auxin Solar.
270.0 W STC · Higher Than 12.9%
270.0 W STC (-115.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
13.84% Aperture Efficiency
Power density 138.4 W/m2 (6.07 percentage points below 19.91% CEC median). PTC/STC ratio: 89.0% (rank #20,637).
12 Panels Max @ -10 C (600 V)
Cold Voc reaches 49.7 V at -10 C (596.4 V string) and 51.15 V at -20 C (11 max).
30 Panels = 8,100 W STC
Occupies 58.5 m2 (630 sq ft) producing 7,209 W PTC; NEC 690.8 OCPD floor is 12.7 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 44.64 * (1 + (-0.324/100) * (-10 - 25)) = 49.7 V | OCPD = 1.56 * 8.14 = 12.7 A
Inputs from CEC Modules.csv for Auxin Solar AXN6M612T270: Voc=44.64 V, beta_Voc=-0.324%/C, Isc=8.14 A, STC=270.0 W, Area=1.951 m2.
Result: 12 panels max on 600 V (596.4 V); 30 panels for 8 kW (630 sq ft).
What Are the Published CEC Specifications for Auxin Solar AXN6M612T270?
Laboratory test ratings recorded for Auxin Solar AXN6M612T270 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 270.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 240.3 W (89.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 44.64 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.14 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 36.21 V / 7.44 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.324 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 13.84% (1.951 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many Auxin Solar AXN6M612T270 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (630 sq ft at 8 kW), and estimated Year-1 electric bill offset for Auxin Solar AXN6M612T270.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 23 | 6.21 kW | 483 sq ft | $1,554 | $2,628 |
| 8 kW Class | 30 | 8.1 kW | 630 sq ft | $2,027 | $3,428 |
| 10 kW Class | 38 | 10.26 kW | 798 sq ft | $2,568 | $4,342 |
Which Sibling Wattage & Trim Variants Belong to This Auxin Solar Series?
Sibling wattage bins and frame colors grouped with Auxin Solar AXN6M612T270 under Auxin Solar to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Auxin Solar AXN6M612T265 | 265.0 W | 235.7 W | 44.42 V | 36.0 V | 13.58% |
| Auxin Solar AXN6M612T270 | 270.0 W | 240.3 W | 44.64 V | 36.21 V | 13.84% |
How Many Auxin Solar AXN6M612T270 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Auxin Solar AXN6M612T270 (beta_Voc -0.324%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 51.15 V | 11 panels | 562.6 V | 19 panels |
| -10 C (14 F) | 49.7 V | 12 panels | 596.4 V | 20 panels |
| 0 C (32 F) | 48.26 V | 12 panels | 579.1 V | 20 panels |
| 25 C (77 F STC) | 44.64 V | 13 panels | 580.3 V | 22 panels |
Which Cross-Brand Solar Modules Compare Closest to Auxin Solar AXN6M612T270?
Closest cross-brand CEC competitors to Auxin Solar AXN6M612T270 matched near 270.0 W STC and 44.64 V Voc, led by Advance Power API-M270.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Advance Power API-M270 Advance Power |
270.0 W | Tie (0 W) | 44.64 V | 13.84% | 89.0% |
| AXITEC AC-270P/156-72S AXITEC |
270.0 W | Tie (0 W) | 44.18 V | 13.94% | 89.9% |
| Centrosolar America DP72 270 Centrosolar America |
270.0 W | Tie (0 W) | 43.85 V | 13.89% | 88.4% |
| Anhui Rinengzhongtian Semiconductor Development QJM270-72 Anhui Rinengzhongtian Semiconductor Development |
270.0 W | Tie (0 W) | 43.67 V | 13.92% | 89.6% |
What Are the Design Limits and Best-Fit Uses for Auxin Solar AXN6M612T270?
Evaluate Auxin Solar AXN6M612T270 (270.0 W STC, 44.64 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Auxin Solar AXN6M612T270 reaches 51.15 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 30 panels for an 8 kW build require 630 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (630 sq ft).
- 2026 tax credit baseline: cash residential installs of Auxin Solar AXN6M612T270 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Auxin Solar AXN6M612T270 8 kW Residential Fit
Needs 30 modules (630 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare Advance Power API-M270.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 240.3 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Auxin Solar AXN6M612T270 by Auxin Solar grounded in CEC test data and NEC 690.7/690.8 limits.
How many Auxin Solar AXN6M612T270 panels fit on a 600 V winter solar string?
At -10 C (14 F), Auxin Solar AXN6M612T270 cold Voc rises from 44.64 V to 49.7 V (beta_Voc -0.324%/C), capping a 600 V string at 12 panels (596.4 V).
How much roof area does an 8 kW array of Auxin Solar AXN6M612T270 need?
An 8 kW DC system uses 30 Auxin Solar AXN6M612T270 modules (8,100 W STC / 7,209 W PTC), covering roughly 630 sq ft and saving ~$2,027/yr at 18.54 c/kWh.
How does Auxin Solar AXN6M612T270 compare against Advance Power API-M270?
Auxin Solar AXN6M612T270 outputs 270.0 W STC (44.64 V Voc, rank #18,572 of 21,677), while Advance Power API-M270 delivers 270.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)