Suntech Power STP270-24/Vdx is a 270.0 W STC (244.7 W PTC) Multi-c-Si solar module ranking #18,572 of 21,677 CEC listings (below all-CEC median; higher than 12.9% of peers). It delivers 13.92% efficiency, 44.5 V Voc at 25 C, and 49.37 V cold Voc at -10 C (12 panels max per 600 V string).
- STC Wattage
- 270.0 W
- PTC Wattage
- 244.7 W
- Voc @ 25C
- 44.5 V
- Efficiency
- 13.92%
How Does Suntech Power STP270-24/Vdx Compare Against Peer CEC Listings?
Solar engineering breakdown for Suntech Power STP270-24/Vdx: PTC thermal retention, roof footprint, and cold Voc string bounds.
Measured at 270.0 W STC and 244.7 W PTC, Suntech Power STP270-24/Vdx sits -115.0 W vs all-CEC median (below all-CEC median; higher than 12.9% of peers) among 21,677 listed modules. Power density reaches 139.2 W/m2 (5.99 percentage points below 19.91% CEC median). Mid-range 44.5 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 20 panels in series. Alternative peer Advance Power API-M270 rates 270.0 W.
Where Does Suntech Power STP270-24/Vdx Fall Across Listed CEC Models?
Distribution marker showing Suntech Power STP270-24/Vdx (270.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Suntech Power STP270-24/Vdx?
Dataset percentiles tracking Suntech Power STP270-24/Vdx power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Suntech Power STP270-24/Vdx?
Benchmark highlights for Suntech Power STP270-24/Vdx covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
270.0 W STC · Higher Than 12.9%
270.0 W STC (-115.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
13.92% Aperture Efficiency
Power density 139.2 W/m2 (5.99 percentage points below 19.91% CEC median). PTC/STC ratio: 90.6% (rank #17,534).
12 Panels Max @ -10 C (600 V)
Cold Voc reaches 49.37 V at -10 C (592.4 V string) and 50.77 V at -20 C (11 max).
30 Panels = 8,100 W STC
Occupies 58.2 m2 (626 sq ft) producing 7,341 W PTC; NEC 690.8 OCPD floor is 12.79 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 44.5 * (1 + (-0.313/100) * (-10 - 25)) = 49.37 V | OCPD = 1.56 * 8.2 = 12.79 A
Inputs from CEC Modules.csv for Suntech Power STP270-24/Vdx: Voc=44.5 V, beta_Voc=-0.313%/C, Isc=8.2 A, STC=270.0 W, Area=1.94 m2.
Result: 12 panels max on 600 V (592.4 V); 30 panels for 8 kW (626 sq ft).
What Are the Published CEC Specifications for Suntech Power STP270-24/Vdx?
Official CEC datasheet figures for Suntech Power STP270-24/Vdx (Multi-c-Si) used in utility interconnection and permit reviews. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 270.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 244.7 W (90.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 44.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.2 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 35.0 V / 7.71 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.313 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 13.92% (1.94 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Multi-c-Si) | Monofacial backsheet |
How Many Suntech Power STP270-24/Vdx Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Suntech Power STP270-24/Vdx modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 23 | 6.21 kW | 480 sq ft | $1,554 | $2,628 |
| 8 kW Class | 30 | 8.1 kW | 626 sq ft | $2,027 | $3,428 |
| 10 kW Class | 38 | 10.26 kW | 794 sq ft | $2,568 | $4,342 |
How Many Suntech Power STP270-24/Vdx Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Suntech Power STP270-24/Vdx (49.37 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 50.77 V | 11 panels | 558.5 V | 19 panels |
| -10 C (14 F) | 49.37 V | 12 panels | 592.4 V | 20 panels |
| 0 C (32 F) | 47.98 V | 12 panels | 575.8 V | 20 panels |
| 25 C (77 F STC) | 44.5 V | 13 panels | 578.5 V | 22 panels |
Which Cross-Brand Solar Modules Compare Closest to Suntech Power STP270-24/Vdx?
Competing CEC solar panels closest to Suntech Power STP270-24/Vdx in nameplate wattage and Voc, starting with Advance Power API-M270.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Advance Power API-M270 Advance Power |
270.0 W | Tie (0 W) | 44.64 V | 13.84% | 89.0% |
| Auxin Solar AXN6M612T270 Auxin Solar |
270.0 W | Tie (0 W) | 44.64 V | 13.84% | 89.0% |
| AXITEC AC-270P/156-72S AXITEC |
270.0 W | Tie (0 W) | 44.18 V | 13.94% | 89.9% |
| Centrosolar America DP72 270 Centrosolar America |
270.0 W | Tie (0 W) | 43.85 V | 13.89% | 88.4% |
What Are the Design Limits and Best-Fit Uses for Suntech Power STP270-24/Vdx?
Evaluate Suntech Power STP270-24/Vdx (270.0 W STC, 44.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Suntech Power STP270-24/Vdx reaches 50.77 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 30 panels for an 8 kW build require 626 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (626 sq ft).
- 2026 tax credit baseline: cash residential installs of Suntech Power STP270-24/Vdx carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Suntech Power STP270-24/Vdx 8 kW Residential Fit
Needs 30 modules (626 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare Advance Power API-M270.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 244.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Suntech Power STP270-24/Vdx by Suntech Power grounded in CEC test data and NEC 690.7/690.8 limits.
How many Suntech Power STP270-24/Vdx panels fit on a 600 V winter solar string?
At -10 C (14 F), Suntech Power STP270-24/Vdx cold Voc rises from 44.5 V to 49.37 V (beta_Voc -0.313%/C), capping a 600 V string at 12 panels (592.4 V).
How much roof area does an 8 kW array of Suntech Power STP270-24/Vdx need?
An 8 kW DC system uses 30 Suntech Power STP270-24/Vdx modules (8,100 W STC / 7,341 W PTC), covering roughly 626 sq ft and saving ~$2,027/yr at 18.54 c/kWh.
How does Suntech Power STP270-24/Vdx compare against Advance Power API-M270?
Suntech Power STP270-24/Vdx outputs 270.0 W STC (44.5 V Voc, rank #18,572 of 21,677), while Advance Power API-M270 delivers 270.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)