Suntech Power STP260-20/Wem — CEC Solar Module Specifications

Manufacturer: Suntech Power Registry: CEC Verified Engineering Specification

Suntech Power STP260-20/Wem is a 260.0 W STC (237.4 W PTC) Multi-c-Si solar module ranking #19,146 of 21,677 CEC listings (below all-CEC median; higher than 10.4% of peers). It delivers 15.98% efficiency, 37.7 V Voc at 25 C, and 42.2 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
260.0 W
PTC Wattage
237.4 W
Voc @ 25C
37.7 V
Efficiency
15.98%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Suntech Power STP260-20/Wem Compare Against Peer CEC Listings?

How Suntech Power Suntech Power STP260-20/Wem handles rooftop heat (237.4 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Suntech Power STP260-20/Wem exhibits 8.89 A short-circuit current, requiring a 13.87 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #19,146 of 21,677 (18.8 W below the 278.8 W Multi-c-Si median), this compact residential or specialty off-grid module covers 50.4 m2 for an 8 kW system (39 panels for 10 kW). Lower 37.7 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.

Where Does Suntech Power STP260-20/Wem Fall Across Listed CEC Models?

Where Suntech Power STP260-20/Wem (260.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Suntech Power STP260-20/Wem (260.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSuntech Power STP2: 260.0 W

What Dataset Percentiles Define Suntech Power STP260-20/Wem?

Percentile placement of Suntech Power STP260-20/Wem across power density (159.8 W/m2), thermal retention, and nameplate STC wattage.

Suntech Power STP260-20/Wem Engineering BenchmarksPercentile comparison of Suntech Power STP260-20/Wem wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage260.0 WPTC/STC Retention91.3%Module Efficiency15.98%

What Do the Dataset Ranks Show for Suntech Power STP260-20/Wem?

Four critical engineering numbers homeowners and solar installers check first when reviewing Suntech Power STP260-20/Wem specifications. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Rank #19,146 / 21,677

260.0 W STC · Higher Than 10.4%

260.0 W STC (-125.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #18,143

15.98% Aperture Efficiency

Power density 159.8 W/m2 (3.93 percentage points below 19.91% CEC median). PTC/STC ratio: 91.3% (rank #16,023).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.2 V at -10 C (590.8 V string) and 43.49 V at -20 C (13 max).

8 kW Reference Array

31 Panels = 8,060 W STC

Occupies 50.4 m2 (543 sq ft) producing 7,359 W PTC; NEC 690.8 OCPD floor is 13.87 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.7 * (1 + (-0.341/100) * (-10 - 25)) = 42.2 V | OCPD = 1.56 * 8.89 = 13.87 A

Inputs from CEC Modules.csv for Suntech Power STP260-20/Wem: Voc=37.7 V, beta_Voc=-0.341%/C, Isc=8.89 A, STC=260.0 W, Area=1.627 m2.

Result: 14 panels max on 600 V (590.8 V); 31 panels for 8 kW (543 sq ft).

What Are the Published CEC Specifications for Suntech Power STP260-20/Wem?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Suntech Power STP260-20/Wem.

Official California Energy Commission (NREL SAM) test parameters for Suntech Power STP260-20/Wem.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 260.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 237.4 W (91.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.7 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.89 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 30.9 V / 8.42 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.341 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 15.98% (1.627 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many Suntech Power STP260-20/Wem Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Suntech Power STP260-20/Wem (260.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 24 6.24 kW 420 sq ft $1,562 $2,641
8 kW Class 31 8.06 kW 543 sq ft $2,017 $3,411
10 kW Class 39 10.14 kW 683 sq ft $2,538 $4,292

Which Sibling Wattage & Trim Variants Belong to This Suntech Power Series?

All closely matched Suntech Power wattages and cosmetic trims sharing the Suntech Power STP260-20/Wem architecture. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Sibling CEC listings grouped into the Suntech Power STP260-20/Wem wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Suntech Power STP250-20/Wem 250.0 W 228.1 W 37.4 V 30.7 V 15.37%
Suntech Power STP255-20/Wem 255.0 W 232.8 W 37.6 V 30.8 V 15.67%
Suntech Power STP260-20/Wem 260.0 W 237.4 W 37.7 V 30.9 V 15.98%
Suntech Power STP265-20/Wem 265.0 W 242.1 W 37.8 V 31.0 V 16.29%
Suntech Power STP270-20/Wem 270.0 W 246.8 W 37.9 V 31.1 V 16.6%

How Many Suntech Power STP260-20/Wem Modules Fit in a Cold-Weather String?

Maximum series module counts for Suntech Power STP260-20/Wem from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=37.7V and beta_Voc=-0.341%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 43.49 V 13 panels 565.4 V 22 panels
-10 C (14 F) 42.2 V 14 panels 590.8 V 23 panels
0 C (32 F) 40.91 V 14 panels 572.7 V 24 panels
25 C (77 F STC) 37.7 V 15 panels 565.5 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to Suntech Power STP260-20/Wem?

Alternative CEC solar modules from competing brands near Suntech Power STP260-20/Wem (260.0 W), including AXITEC AC-260M/156-60S.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
AXITEC AC-260M/156-60S
AXITEC
260.0 W Tie (0 W) 37.73 V 16.02% 90.2%
AXITEC AC-260P/156-60S
AXITEC
260.0 W Tie (0 W) 37.65 V 16.02% 89.0%
Centrosolar America EP6 260BW
Centrosolar America
260.0 W Tie (0 W) 37.65 V 16.02% 89.0%
Centrosolar America EP6 260SW
Centrosolar America
260.0 W Tie (0 W) 37.65 V 16.02% 89.0%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Suntech Power STP260-20/Wem?

Evaluate Suntech Power STP260-20/Wem (260.0 W STC, 37.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Suntech Power STP260-20/Wem reaches 43.49 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 31 panels for an 8 kW build require 543 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (543 sq ft).
  • 2026 tax credit baseline: cash residential installs of Suntech Power STP260-20/Wem carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Suntech Power STP260-20/Wem 8 kW Residential Fit

Needs 31 modules (543 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare AXITEC AC-260M/156-60S.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 237.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Suntech Power STP260-20/Wem by Suntech Power grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Suntech Power STP260-20/Wem PTC wattage (237.4 W) lower than STC (260.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 237.4 W PTC (91.3% retention) across Suntech Power STP260-20/Wem's 1.627 m2 aperture.

Who should skip Suntech Power STP260-20/Wem on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 31 Suntech Power STP260-20/Wem panels (543 sq ft) leave unusable roof gaps vs. AXITEC AC-260M/156-60S.

What is the 1,000 V commercial string limit for Suntech Power STP260-20/Wem?

On 1,000 V commercial inverters at -10 C (42.2 V cold Voc), Suntech Power STP260-20/Wem fits up to 23 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Suntech Power STP260-20/Wem.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.