Skip to main content
WireAndSun
Calculators
CEC PV Module

Suntech Power STP255S-20/Wde — CEC Solar Module Specifications

Manufacturer: Suntech Power Registry: CEC Verified Engineering Specification

Suntech Power STP255S-20/Wde is a 255.0 W STC (232.7 W PTC) Mono-c-Si solar module ranking #19,421 of 21,677 CEC listings (below all-CEC median; higher than 9.2% of peers). It delivers 15.67% efficiency, 37.5 V Voc at 25 C, and 41.96 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
255.0 W
PTC Wattage
232.7 W
Voc @ 25C
37.5 V
Efficiency
15.67%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Suntech Power STP255S-20/Wde Compare Against Peer CEC Listings?

Solar engineering breakdown for Suntech Power STP255S-20/Wde: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 255.0 W STC and 232.7 W PTC, Suntech Power STP255S-20/Wde sits -130.0 W vs all-CEC median (below all-CEC median; higher than 9.2% of peers) among 21,677 listed modules. Power density reaches 156.7 W/m2 (4.24 percentage points below 19.91% CEC median). Lower 37.5 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 23 panels in series. Alternative peer Advance Power API-P255 rates 255.0 W.

Where Does Suntech Power STP255S-20/Wde Fall Across Listed CEC Models?

Distribution marker showing Suntech Power STP255S-20/Wde (255.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Suntech Power STP255S-20/Wde (255.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSuntech Power STP2: 255.0 W

What Dataset Percentiles Define Suntech Power STP255S-20/Wde?

Dataset percentiles tracking Suntech Power STP255S-20/Wde power output, thermal retention ratio, and aperture efficiency against 21,677 models.

Suntech Power STP255S-20/Wde Engineering BenchmarksPercentile comparison of Suntech Power STP255S-20/Wde wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage255.0 WPTC/STC Retention91.3%Module Efficiency15.67%

What Do the Dataset Ranks Show for Suntech Power STP255S-20/Wde?

Benchmark highlights for Suntech Power STP255S-20/Wde covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #19,421 / 21,677

255.0 W STC · Higher Than 9.2%

255.0 W STC (-130.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #18,676

15.67% Aperture Efficiency

Power density 156.7 W/m2 (4.24 percentage points below 19.91% CEC median). PTC/STC ratio: 91.3% (rank #16,023).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 41.96 V at -10 C (587.4 V string) and 43.24 V at -20 C (13 max).

8 kW Reference Array

32 Panels = 8,160 W STC

Occupies 52.1 m2 (560 sq ft) producing 7,446 W PTC; NEC 690.8 OCPD floor is 13.62 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.5 * (1 + (-0.34/100) * (-10 - 25)) = 41.96 V | OCPD = 1.56 * 8.73 = 13.62 A

Inputs from CEC Modules.csv for Suntech Power STP255S-20/Wde: Voc=37.5 V, beta_Voc=-0.34%/C, Isc=8.73 A, STC=255.0 W, Area=1.627 m2.

Result: 14 panels max on 600 V (587.4 V); 32 panels for 8 kW (560 sq ft).

What Are the Published CEC Specifications for Suntech Power STP255S-20/Wde?

Official CEC datasheet figures for Suntech Power STP255S-20/Wde (Mono-c-Si) used in utility interconnection and permit reviews. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Official California Energy Commission (NREL SAM) test parameters for Suntech Power STP255S-20/Wde.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 255.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 232.7 W (91.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.5 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.73 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 30.9 V / 8.26 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.34 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 15.67% (1.627 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many Suntech Power STP255S-20/Wde Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Suntech Power STP255S-20/Wde modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 24 6.12 kW 420 sq ft $1,532 $2,590
8 kW Class 32 8.16 kW 560 sq ft $2,042 $3,454
10 kW Class 40 10.2 kW 701 sq ft $2,553 $4,317

Which Sibling Wattage & Trim Variants Belong to This Suntech Power Series?

Consolidated Suntech Power wattage variants sharing the Suntech Power STP255S-20/Wde mechanical and cell layout. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Sibling CEC listings grouped into the Suntech Power STP255S-20/Wde wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Suntech Power STP250S-20/Wde 250.0 W 226.3 W 37.4 V 30.7 V 15.37%
Suntech Power STP255S-20/Wde 255.0 W 232.7 W 37.5 V 30.9 V 15.67%
Suntech Power STP260S-20/Wde 260.0 W 237.3 W 37.6 V 31.1 V 15.98%

How Many Suntech Power STP255S-20/Wde Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Suntech Power STP255S-20/Wde (41.96 V at 14 F).

Computed from Voc=37.5V and beta_Voc=-0.34%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 43.24 V 13 panels 562.1 V 23 panels
-10 C (14 F) 41.96 V 14 panels 587.4 V 23 panels
0 C (32 F) 40.69 V 14 panels 569.7 V 24 panels
25 C (77 F STC) 37.5 V 16 panels 600.0 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to Suntech Power STP255S-20/Wde?

Competing CEC solar panels closest to Suntech Power STP255S-20/Wde in nameplate wattage and Voc, starting with Advance Power API-P255.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Advance Power API-P255
Advance Power
255.0 W Tie (0 W) 37.5 V 15.57% 89.4%
Auxin Solar AXN6P610T255
Auxin Solar
255.0 W Tie (0 W) 37.5 V 15.57% 89.4%
Eoplly New Energy Technology EP156M/60-255 AC
Eoplly New Energy Technology
255.0 W Tie (0 W) 37.56 V 15.76% 89.9%
Eoplly New Energy Technology EP156M/60-255S AC
Eoplly New Energy Technology
255.0 W Tie (0 W) 37.56 V 15.76% 89.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Suntech Power STP255S-20/Wde?

Evaluate Suntech Power STP255S-20/Wde (255.0 W STC, 37.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Suntech Power STP255S-20/Wde reaches 43.24 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 32 panels for an 8 kW build require 560 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 32 panels (560 sq ft).
  • 2026 tax credit baseline: cash residential installs of Suntech Power STP255S-20/Wde carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Suntech Power STP255S-20/Wde 8 kW Residential Fit

Needs 32 modules (560 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Advance Power API-P255.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 232.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Suntech Power STP255S-20/Wde by Suntech Power grounded in CEC test data and NEC 690.7/690.8 limits.

How many Suntech Power STP255S-20/Wde panels fit on a 600 V winter solar string?

At -10 C (14 F), Suntech Power STP255S-20/Wde cold Voc rises from 37.5 V to 41.96 V (beta_Voc -0.34%/C), capping a 600 V string at 14 panels (587.4 V).

How much roof area does an 8 kW array of Suntech Power STP255S-20/Wde need?

An 8 kW DC system uses 32 Suntech Power STP255S-20/Wde modules (8,160 W STC / 7,446 W PTC), covering roughly 560 sq ft and saving ~$2,042/yr at 18.54 c/kWh.

How does Suntech Power STP255S-20/Wde compare against Advance Power API-P255?

Suntech Power STP255S-20/Wde outputs 255.0 W STC (37.5 V Voc, rank #19,421 of 21,677), while Advance Power API-P255 delivers 255.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.