Skip to main content
WireAndSun
Calculators
CEC PV Module

Sunrise Solartech SR-P660230 — CEC Solar Module Specifications

Manufacturer: Sunrise Solartech Registry: CEC Verified Engineering Specification

Sunrise Solartech SR-P660230 is a 230.0 W STC (204.2 W PTC) Multi-c-Si solar module ranking #20,522 of 21,677 CEC listings (below all-CEC median; higher than 4.7% of peers). It delivers 14.16% efficiency, 35.84 V Voc at 25 C, and 40.34 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
230.0 W
PTC Wattage
204.2 W
Voc @ 25C
35.84 V
Efficiency
14.16%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Sunrise Solartech SR-P660230 Compare Against Peer CEC Listings?

Solar engineering breakdown for Sunrise Solartech SR-P660230: PTC thermal retention, roof footprint, and cold Voc string bounds. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Measured at 230.0 W STC and 204.2 W PTC, Sunrise Solartech SR-P660230 sits -155.0 W vs all-CEC median (below all-CEC median; higher than 4.7% of peers) among 21,677 listed modules. Power density reaches 141.6 W/m2 (5.75 percentage points below 19.91% CEC median). Lower 35.84 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 24 panels in series. Alternative peer Gintung Energy ASEC-230G6S rates 230.0 W.

Where Does Sunrise Solartech SR-P660230 Fall Across Listed CEC Models?

Distribution marker showing Sunrise Solartech SR-P660230 (230.0 W) relative to the 385.0 W all-CEC solar panel median. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Sunrise Solartech SR-P660230 (230.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSunrise Solartech : 230.0 W

What Dataset Percentiles Define Sunrise Solartech SR-P660230?

Dataset percentiles tracking Sunrise Solartech SR-P660230 power output, thermal retention ratio, and aperture efficiency against 21,677 models. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Sunrise Solartech SR-P660230 Engineering BenchmarksPercentile comparison of Sunrise Solartech SR-P660230 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage230.0 WPTC/STC Retention88.8%Module Efficiency14.16%

What Do the Dataset Ranks Show for Sunrise Solartech SR-P660230?

Benchmark highlights for Sunrise Solartech SR-P660230 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Rank #20,522 / 21,677

230.0 W STC · Higher Than 4.7%

230.0 W STC (-155.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #20,764

14.16% Aperture Efficiency

Power density 141.6 W/m2 (5.75 percentage points below 19.91% CEC median). PTC/STC ratio: 88.8% (rank #20,967).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.34 V at -10 C (564.8 V string) and 41.63 V at -20 C (14 max).

8 kW Reference Array

35 Panels = 8,050 W STC

Occupies 56.8 m2 (612 sq ft) producing 7,147 W PTC; NEC 690.8 OCPD floor is 13.35 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 35.84 * (1 + (-0.359/100) * (-10 - 25)) = 40.34 V | OCPD = 1.56 * 8.56 = 13.35 A

Inputs from CEC Modules.csv for Sunrise Solartech SR-P660230: Voc=35.84 V, beta_Voc=-0.359%/C, Isc=8.56 A, STC=230.0 W, Area=1.624 m2.

Result: 14 panels max on 600 V (564.8 V); 35 panels for 8 kW (612 sq ft).

What Are the Published CEC Specifications for Sunrise Solartech SR-P660230?

Official CEC datasheet figures for Sunrise Solartech SR-P660230 (Multi-c-Si) used in utility interconnection and permit reviews. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Official California Energy Commission (NREL SAM) test parameters for Sunrise Solartech SR-P660230.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 230.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 204.2 W (88.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 35.84 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.56 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 28.9 V / 7.96 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.359 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.16% (1.624 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many Sunrise Solartech SR-P660230 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Sunrise Solartech SR-P660230 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 27 6.21 kW 472 sq ft $1,554 $2,628
8 kW Class 35 8.05 kW 612 sq ft $2,015 $3,407
10 kW Class 44 10.12 kW 769 sq ft $2,533 $4,283

How Many Sunrise Solartech SR-P660230 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Sunrise Solartech SR-P660230 (40.34 V at 14 F).

Computed from Voc=35.84V and beta_Voc=-0.359%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 41.63 V 14 panels 582.8 V 24 panels
-10 C (14 F) 40.34 V 14 panels 564.8 V 24 panels
0 C (32 F) 39.06 V 15 panels 585.9 V 25 panels
25 C (77 F STC) 35.84 V 16 panels 573.4 V 27 panels

Which Cross-Brand Solar Modules Compare Closest to Sunrise Solartech SR-P660230?

Competing CEC solar panels closest to Sunrise Solartech SR-P660230 in nameplate wattage and Voc, starting with Gintung Energy ASEC-230G6S.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Gintung Energy ASEC-230G6S
Gintung Energy
230.0 W Tie (0 W) 36.75 V 14.28% 89.7%
Grape Solar GS-P-230-CS
Grape Solar
230.0 W Tie (0 W) 36.8 V 14.3% 91.7%
Gintung Energy ASEC-230G6M
Gintung Energy
230.0 W Tie (0 W) 36.87 V 14.28% 89.4%
Anji Dasol Solar Energy Science & Technology DS-A4-230
Anji Dasol Solar Energy Science & Technology
230.0 W Tie (0 W) 36.9 V 13.97% 87.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Sunrise Solartech SR-P660230?

Evaluate Sunrise Solartech SR-P660230 (230.0 W STC, 35.84 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Sunrise Solartech SR-P660230 reaches 41.63 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 35 panels for an 8 kW build require 612 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 35 panels (612 sq ft).
  • 2026 tax credit baseline: cash residential installs of Sunrise Solartech SR-P660230 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Sunrise Solartech SR-P660230 8 kW Residential Fit

Needs 35 modules (612 sq ft) with a 15 A string OCPD, offsetting ~$2,015/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Gintung Energy ASEC-230G6S.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 204.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Sunrise Solartech SR-P660230 by Sunrise Solartech grounded in CEC test data and NEC 690.7/690.8 limits.

How many Sunrise Solartech SR-P660230 panels fit on a 600 V winter solar string?

At -10 C (14 F), Sunrise Solartech SR-P660230 cold Voc rises from 35.84 V to 40.34 V (beta_Voc -0.359%/C), capping a 600 V string at 14 panels (564.8 V).

How much roof area does an 8 kW array of Sunrise Solartech SR-P660230 need?

An 8 kW DC system uses 35 Sunrise Solartech SR-P660230 modules (8,050 W STC / 7,147 W PTC), covering roughly 612 sq ft and saving ~$2,015/yr at 18.54 c/kWh.

How does Sunrise Solartech SR-P660230 compare against Gintung Energy ASEC-230G6S?

Sunrise Solartech SR-P660230 outputs 230.0 W STC (35.84 V Voc, rank #20,522 of 21,677), while Gintung Energy ASEC-230G6S delivers 230.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.