Manufacturer: SunPower Registry: CEC Verified Engineering Specification

SunPower SPR-X20-450-COM is a 450.0 W STC (418.9 W PTC) Mono-c-Si solar module ranking #5,679 of 21,677 CEC listings (top 27.8%; higher than 72.2% of peers). It delivers 20.83% efficiency, 90.5 V Voc at 25 C, and 99.78 V cold Voc at -10 C (6 panels max per 600 V string).

STC Wattage
450.0 W
PTC Wattage
418.9 W
Voc @ 25C
90.5 V
Efficiency
20.83%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SunPower SPR-X20-450-COM Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for SunPower SPR-X20-450-COM (Mono-c-Si) residential solar systems. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

SunPower SPR-X20-450-COM delivers 208.3 W/m2 (0.92 percentage points above 19.91% CEC median) and strong 93.1% PTC-to-STC heat retention (#9,420 of 21,677), placing it as a modern high-density residential and light-commercial module well-proportioned for residential pitched roofs needing 18 panels (419 sq ft) for an 8 kW array. At -4 F (-20 C), string voltage climbs to 102.43 V per unit, capping 600 V circuits at 5 panels. Compare specs directly with Heliene 96M460 (460.0 W).

Where Does SunPower SPR-X20-450-COM Fall Across Listed CEC Models?

Comparison of SunPower SPR-X20-450-COM (450.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where SunPower SPR-X20-450-COM (450.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSunPower SPR-X20-4: 450.0 W

What Dataset Percentiles Define SunPower SPR-X20-450-COM?

Relative ranking of SunPower SPR-X20-450-COM across nameplate watts, 93.1% PTC thermal ratio, and module aperture efficiency. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

SunPower SPR-X20-450-COM Engineering BenchmarksPercentile comparison of SunPower SPR-X20-450-COM wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage450.0 WPTC/STC Retention93.1%Module Efficiency20.83%

What Do the Dataset Ranks Show for SunPower SPR-X20-450-COM?

Summary of SunPower SPR-X20-450-COM output rank, 8 kW array size (18 panels), efficiency rating, and 600 V string limit.

Rank #5,679 / 21,677

Top 27.8% STC Output

450.0 W STC (+65.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #7,094

20.83% Aperture Efficiency

Power density 208.3 W/m2 (0.92 percentage points above 19.91% CEC median). PTC/STC ratio: 93.1% (rank #9,420).

NEC 690.7 Limit

6 Panels Max @ -10 C (600 V)

Cold Voc reaches 99.78 V at -10 C (598.7 V string) and 102.43 V at -20 C (5 max).

8 kW Reference Array

18 Panels = 8,100 W STC

Occupies 38.9 m2 (419 sq ft) producing 7,540 W PTC; NEC 690.8 OCPD floor is 9.77 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 90.5 * (1 + (-0.293/100) * (-10 - 25)) = 99.78 V | OCPD = 1.56 * 6.26 = 9.77 A

Inputs from CEC Modules.csv for SunPower SPR-X20-450-COM: Voc=90.5 V, beta_Voc=-0.293%/C, Isc=6.26 A, STC=450.0 W, Area=2.16 m2.

Result: 6 panels max on 600 V (598.7 V); 18 panels for 8 kW (419 sq ft).

What Are the Published CEC Specifications for SunPower SPR-X20-450-COM?

Complete CEC test sheet for SunPower SPR-X20-450-COM including Isc (6.26 A), Voc (90.5 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for SunPower SPR-X20-450-COM.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 450.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 418.9 W (93.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 90.5 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 6.26 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 76.7 V / 5.87 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.293 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.83% (2.16 m2) Array roof footprint density
Cell Count & Technology 128 cells (Mono-c-Si) Monofacial backsheet

How Many SunPower SPR-X20-450-COM Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using SunPower SPR-X20-450-COM.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.3 kW 326 sq ft $1,577 $2,666
8 kW Class 18 8.1 kW 419 sq ft $2,027 $3,428
10 kW Class 23 10.35 kW 535 sq ft $2,591 $4,380

How Many SunPower SPR-X20-450-COM Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for SunPower SPR-X20-450-COM (90.5 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=90.5V and beta_Voc=-0.293%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 102.43 V 5 panels 512.2 V 9 panels
-10 C (14 F) 99.78 V 6 panels 598.7 V 10 panels
0 C (32 F) 97.13 V 6 panels 582.8 V 10 panels
25 C (77 F STC) 90.5 V 6 panels 543.0 V 11 panels

Which Cross-Brand Solar Modules Compare Closest to SunPower SPR-X20-450-COM?

Four comparable CEC modules such as Heliene 96M460 (460.0 W) for side-by-side solar quote checks. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Heliene 96M460
Heliene
460.0 W +10.0 W 61.79 V 18.25% 90.4%
Heliene 96M475
Heliene
475.0 W +25.0 W 62.39 V 18.85% 90.5%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-450W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
450.0 W Tie (0 W) 50.0 V 21.23% 92.5%
AXITEC AC-450MH/144V
AXITEC
450.0 W Tie (0 W) 50.0 V 21.23% 92.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for SunPower SPR-X20-450-COM?

Evaluate SunPower SPR-X20-450-COM (450.0 W STC, 90.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), SunPower SPR-X20-450-COM reaches 102.43 V per panel—exceeding 5 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 18 panels for an 8 kW build require 419 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (419 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of SunPower SPR-X20-450-COM carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

SunPower SPR-X20-450-COM 8 kW Residential Fit

Needs 18 modules (419 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 6 panels (-10 C) or 5 panels (-20 C), or compare Heliene 96M460.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 418.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for SunPower SPR-X20-450-COM by SunPower grounded in CEC test data and NEC 690.7/690.8 limits. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

How many SunPower SPR-X20-450-COM panels fit on a 600 V winter solar string?

At -10 C (14 F), SunPower SPR-X20-450-COM cold Voc rises from 90.5 V to 99.78 V (beta_Voc -0.293%/C), capping a 600 V string at 6 panels (598.7 V).

How much roof area does an 8 kW array of SunPower SPR-X20-450-COM need?

An 8 kW DC system uses 18 SunPower SPR-X20-450-COM modules (8,100 W STC / 7,540 W PTC), covering roughly 419 sq ft and saving ~$2,027/yr at 18.54 c/kWh.

How does SunPower SPR-X20-450-COM compare against Heliene 96M460?

SunPower SPR-X20-450-COM outputs 450.0 W STC (90.5 V Voc, rank #5,679 of 21,677), while Heliene 96M460 delivers 460.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.