Skip to main content
WireAndSun
Calculators
CEC PV Module

SunPower SPR-X22-470-COM — CEC Solar Module Specifications

Manufacturer: SunPower Registry: CEC Verified Engineering Specification

SunPower SPR-X22-470-COM is a 470.0 W STC (438.0 W PTC) Mono-c-Si solar module ranking #4,967 of 21,677 CEC listings (top 23.4%; higher than 76.6% of peers). It delivers 21.74% efficiency, 91.8 V Voc at 25 C, and 101.21 V cold Voc at -10 C (5 panels max per 600 V string).

STC Wattage
470.0 W
PTC Wattage
438.0 W
Voc @ 25C
91.8 V
Efficiency
21.74%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SunPower SPR-X22-470-COM Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for SunPower SPR-X22-470-COM (Mono-c-Si) residential solar systems. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Homeowners evaluating SunPower SPR-X22-470-COM need 13 panels for 6 kW or 18 panels (419 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 18 panels (419 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.293%/C) pushes open-circuit voltage to 101.21 V at 14 F and 103.9 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does SunPower SPR-X22-470-COM Fall Across Listed CEC Models?

Comparison of SunPower SPR-X22-470-COM (470.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where SunPower SPR-X22-470-COM (470.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSunPower SPR-X22-4: 470.0 W

What Dataset Percentiles Define SunPower SPR-X22-470-COM?

Relative ranking of SunPower SPR-X22-470-COM across nameplate watts, 93.2% PTC thermal ratio, and module aperture efficiency. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

SunPower SPR-X22-470-COM Engineering BenchmarksPercentile comparison of SunPower SPR-X22-470-COM wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage470.0 WPTC/STC Retention93.2%Module Efficiency21.74%

What Do the Dataset Ranks Show for SunPower SPR-X22-470-COM?

Summary of SunPower SPR-X22-470-COM output rank, 8 kW array size (18 panels), efficiency rating, and 600 V string limit.

Rank #4,967 / 21,677

Top 23.4% STC Output

470.0 W STC (+85.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #3,743

21.74% Aperture Efficiency

Power density 217.4 W/m2 (1.83 percentage points above 19.91% CEC median). PTC/STC ratio: 93.2% (rank #8,924).

NEC 690.7 Limit

5 Panels Max @ -10 C (600 V)

Cold Voc reaches 101.21 V at -10 C (506.0 V string) and 103.9 V at -20 C (5 max).

8 kW Reference Array

18 Panels = 8,460 W STC

Occupies 38.9 m2 (419 sq ft) producing 7,884 W PTC; NEC 690.8 OCPD floor is 10.03 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 91.8 * (1 + (-0.293/100) * (-10 - 25)) = 101.21 V | OCPD = 1.56 * 6.43 = 10.03 A

Inputs from CEC Modules.csv for SunPower SPR-X22-470-COM: Voc=91.8 V, beta_Voc=-0.293%/C, Isc=6.43 A, STC=470.0 W, Area=2.162 m2.

Result: 5 panels max on 600 V (506.0 V); 18 panels for 8 kW (419 sq ft).

What Are the Published CEC Specifications for SunPower SPR-X22-470-COM?

Complete CEC test sheet for SunPower SPR-X22-470-COM including Isc (6.43 A), Voc (91.8 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for SunPower SPR-X22-470-COM.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 470.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 438.0 W (93.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 91.8 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 6.43 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 77.9 V / 6.03 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.293 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.74% (2.162 m2) Array roof footprint density
Cell Count & Technology 128 cells (Mono-c-Si) Monofacial backsheet

How Many SunPower SPR-X22-470-COM Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using SunPower SPR-X22-470-COM.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 13 6.11 kW 303 sq ft $1,529 $2,586
8 kW Class 18 8.46 kW 419 sq ft $2,117 $3,580
10 kW Class 22 10.34 kW 512 sq ft $2,588 $4,376

Which Sibling Wattage & Trim Variants Belong to This SunPower Series?

Related SunPower power steps and black/silver trims consolidated into this SunPower SPR-X22-470-COM series guide. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Sibling CEC listings grouped into the SunPower SPR-X22-470-COM wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
SunPower SPR-X22-460-COM 460.0 W 428.4 W 90.5 V 76.7 V 21.28%
SunPower SPR-X22-470-COM 470.0 W 438.0 W 91.8 V 77.9 V 21.74%

How Many SunPower SPR-X22-470-COM Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for SunPower SPR-X22-470-COM (91.8 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=91.8V and beta_Voc=-0.293%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 103.9 V 5 panels 519.5 V 9 panels
-10 C (14 F) 101.21 V 5 panels 506.0 V 9 panels
0 C (32 F) 98.52 V 6 panels 591.1 V 10 panels
25 C (77 F STC) 91.8 V 6 panels 550.8 V 10 panels

Which Cross-Brand Solar Modules Compare Closest to SunPower SPR-X22-470-COM?

Four comparable CEC modules such as Heliene 96M475 (475.0 W) for side-by-side solar quote checks. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Heliene 96M475
Heliene
475.0 W +5.0 W 62.39 V 18.85% 90.5%
Heliene 96M460
Heliene
460.0 W -10.0 W 61.79 V 18.25% 90.4%
CSI Solar Co Ltd CS3Y-470MS
CSI Solar Co Ltd
470.0 W Tie (0 W) 52.5 V 20.52% 93.5%
CSI Solar Co Ltd CS3Y-480P
CSI Solar Co Ltd
480.0 W +10.0 W 52.8 V 20.96% 93.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for SunPower SPR-X22-470-COM?

Evaluate SunPower SPR-X22-470-COM (470.0 W STC, 91.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), SunPower SPR-X22-470-COM reaches 103.9 V per panel—exceeding 5 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 18 panels for an 8 kW build require 419 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (419 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of SunPower SPR-X22-470-COM carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

SunPower SPR-X22-470-COM 8 kW Residential Fit

Needs 18 modules (419 sq ft) with a 15 A string OCPD, offsetting ~$2,117/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 5 panels (-10 C) or 5 panels (-20 C), or compare Heliene 96M475.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 438.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for SunPower SPR-X22-470-COM by SunPower grounded in CEC test data and NEC 690.7/690.8 limits. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Why is SunPower SPR-X22-470-COM PTC wattage (438.0 W) lower than STC (470.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 438.0 W PTC (93.2% retention) across SunPower SPR-X22-470-COM's 2.162 m2 aperture.

Who should skip SunPower SPR-X22-470-COM on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 18 SunPower SPR-X22-470-COM panels (419 sq ft) leave unusable roof gaps vs. Heliene 96M475.

What is the 1,000 V commercial string limit for SunPower SPR-X22-470-COM?

On 1,000 V commercial inverters at -10 C (101.21 V cold Voc), SunPower SPR-X22-470-COM fits up to 9 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting SunPower SPR-X22-470-COM.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.