Skip to main content
WireAndSun
Calculators
CEC PV Module

SunPower SPR-X22-485-COM — CEC Solar Module Specifications

Manufacturer: SunPower Registry: CEC Verified Engineering Specification

SunPower SPR-X22-485-COM is a 485.0 W STC (457.7 W PTC) Mono-c-Si solar module ranking #4,730 of 21,677 CEC listings (top 22.2%; higher than 77.8% of peers). It delivers 22.45% efficiency, 92.7 V Voc at 25 C, and 100.36 V cold Voc at -10 C (5 panels max per 600 V string).

STC Wattage
485.0 W
PTC Wattage
457.7 W
Voc @ 25C
92.7 V
Efficiency
22.45%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SunPower SPR-X22-485-COM Compare Against Peer CEC Listings?

Engineering position of SunPower SPR-X22-485-COM (485.0 W STC) vs. Heliene 96M475 across 5,889 CEC Mono-c-Si solar modules. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Ranking #4,730 across 21,677 CEC solar panels (top 22.2%; higher than 77.8% of peers), SunPower SPR-X22-485-COM operates as a modern high-density residential and light-commercial module sitting 75.0 W above the 410.0 W Mono-c-Si median. Higher 92.7 V open-circuit voltage caps 600 V residential strings at 5 panels at 14 F (-10 C). With strong 94.4% PTC-to-STC heat retention (#2,840 of 21,677), 17 panels occupy 395 sq ft and offset roughly $2,062/yr at average US rates (or $3,487/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does SunPower SPR-X22-485-COM Fall Across Listed CEC Models?

Plots SunPower SPR-X22-485-COM at 485.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where SunPower SPR-X22-485-COM (485.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSunPower SPR-X22-4: 485.0 W

What Dataset Percentiles Define SunPower SPR-X22-485-COM?

Benchmarks SunPower SPR-X22-485-COM on STC wattage, thermal PTC/STC retention, and 22.45 aperture conversion efficiency against CEC peers.

SunPower SPR-X22-485-COM Engineering BenchmarksPercentile comparison of SunPower SPR-X22-485-COM wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage485.0 WPTC/STC Retention94.4%Module Efficiency22.45%

What Do the Dataset Ranks Show for SunPower SPR-X22-485-COM?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for SunPower SPR-X22-485-COM by SunPower.

Rank #4,730 / 21,677

Top 22.2% STC Output

485.0 W STC (+100.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #2,153

22.45% Aperture Efficiency

Power density 224.5 W/m2 (2.54 percentage points above 19.91% CEC median). PTC/STC ratio: 94.4% (rank #2,840).

NEC 690.7 Limit

5 Panels Max @ -10 C (600 V)

Cold Voc reaches 100.36 V at -10 C (501.8 V string) and 102.54 V at -20 C (5 max).

8 kW Reference Array

17 Panels = 8,245 W STC

Occupies 36.7 m2 (395 sq ft) producing 7,781 W PTC; NEC 690.8 OCPD floor is 10.22 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 92.7 * (1 + (-0.236/100) * (-10 - 25)) = 100.36 V | OCPD = 1.56 * 6.55 = 10.22 A

Inputs from CEC Modules.csv for SunPower SPR-X22-485-COM: Voc=92.7 V, beta_Voc=-0.236%/C, Isc=6.55 A, STC=485.0 W, Area=2.16 m2.

Result: 5 panels max on 600 V (501.8 V); 17 panels for 8 kW (395 sq ft).

What Are the Published CEC Specifications for SunPower SPR-X22-485-COM?

Laboratory test ratings recorded for SunPower SPR-X22-485-COM (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for SunPower SPR-X22-485-COM.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 485.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 457.7 W (94.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 92.7 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 6.55 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 78.8 V / 6.16 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.236 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 22.45% (2.16 m2) Array roof footprint density
Cell Count & Technology 128 cells (Mono-c-Si) Monofacial backsheet

How Many SunPower SPR-X22-485-COM Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (395 sq ft at 8 kW), and estimated Year-1 electric bill offset for SunPower SPR-X22-485-COM.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 13 6.3 kW 302 sq ft $1,577 $2,666
8 kW Class 17 8.24 kW 395 sq ft $2,062 $3,487
10 kW Class 21 10.19 kW 488 sq ft $2,550 $4,313

Which Sibling Wattage & Trim Variants Belong to This SunPower Series?

Sibling wattage bins and frame colors grouped with SunPower SPR-X22-485-COM under SunPower to prevent duplicate spec pages. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Sibling CEC listings grouped into the SunPower SPR-X22-485-COM wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
SunPower SPR-X22-475-COM 475.0 W 442.8 W 92.5 V 78.5 V 21.97%
SunPower SPR-X22-480-COM 480.0 W 452.9 W 92.7 V 79.0 V 22.22%
SunPower SPR-X22-485-COM 485.0 W 457.7 W 92.7 V 78.8 V 22.45%

How Many SunPower SPR-X22-485-COM Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for SunPower SPR-X22-485-COM (beta_Voc -0.236%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=92.7V and beta_Voc=-0.236%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 102.54 V 5 panels 512.7 V 9 panels
-10 C (14 F) 100.36 V 5 panels 501.8 V 9 panels
0 C (32 F) 98.17 V 6 panels 589.0 V 10 panels
25 C (77 F STC) 92.7 V 6 panels 556.2 V 10 panels

Which Cross-Brand Solar Modules Compare Closest to SunPower SPR-X22-485-COM?

Closest cross-brand CEC competitors to SunPower SPR-X22-485-COM matched near 485.0 W STC and 92.7 V Voc, led by Heliene 96M475.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Heliene 96M475
Heliene
475.0 W -10.0 W 62.39 V 18.85% 90.5%
Heliene 96M460
Heliene
460.0 W -25.0 W 61.79 V 18.25% 90.4%
CSI Solar Co Ltd CS3Y-485MS
CSI Solar Co Ltd
485.0 W Tie (0 W) 53.1 V 21.18% 93.6%
CSI Solar Co Ltd CS3Y-480P
CSI Solar Co Ltd
480.0 W -5.0 W 52.8 V 20.96% 93.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for SunPower SPR-X22-485-COM?

Evaluate SunPower SPR-X22-485-COM (485.0 W STC, 92.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), SunPower SPR-X22-485-COM reaches 102.54 V per panel—exceeding 5 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 17 panels for an 8 kW build require 395 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 17 panels (395 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of SunPower SPR-X22-485-COM carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

SunPower SPR-X22-485-COM 8 kW Residential Fit

Needs 17 modules (395 sq ft) with a 15 A string OCPD, offsetting ~$2,062/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 5 panels (-10 C) or 5 panels (-20 C), or compare Heliene 96M475.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 457.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for SunPower SPR-X22-485-COM by SunPower grounded in CEC test data and NEC 690.7/690.8 limits. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

How many SunPower SPR-X22-485-COM panels fit on a 600 V winter solar string?

At -10 C (14 F), SunPower SPR-X22-485-COM cold Voc rises from 92.7 V to 100.36 V (beta_Voc -0.236%/C), capping a 600 V string at 5 panels (501.8 V).

How much roof area does an 8 kW array of SunPower SPR-X22-485-COM need?

An 8 kW DC system uses 17 SunPower SPR-X22-485-COM modules (8,245 W STC / 7,781 W PTC), covering roughly 395 sq ft and saving ~$2,062/yr at 18.54 c/kWh.

How does SunPower SPR-X22-485-COM compare against Heliene 96M475?

SunPower SPR-X22-485-COM outputs 485.0 W STC (92.7 V Voc, rank #4,730 of 21,677), while Heliene 96M475 delivers 475.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.