SunPower SPR-X21-470-COM is a 470.0 W STC (438.0 W PTC) Mono-c-Si solar module ranking #4,967 of 21,677 CEC listings (top 23.4%; higher than 76.6% of peers). It delivers 21.76% efficiency, 91.8 V Voc at 25 C, and 101.21 V cold Voc at -10 C (5 panels max per 600 V string).
- STC Wattage
- 470.0 W
- PTC Wattage
- 438.0 W
- Voc @ 25C
- 91.8 V
- Efficiency
- 21.76%
How Does SunPower SPR-X21-470-COM Compare Against Peer CEC Listings?
How SunPower SunPower SPR-X21-470-COM handles rooftop heat (438.0 W PTC), 8 kW sizing, and cold winter string voltage.
SunPower builds the SunPower SPR-X21-470-COM (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 217.6 W/m2 (1.85 percentage points above 19.91% CEC median). Compared against Heliene 96M475 (475.0 W), this model holds strong 93.2% PTC-to-STC heat retention (#8,924 of 21,677). Higher 91.8 V open-circuit voltage caps 600 V residential strings at 5 panels at 14 F (-10 C), while NEC 690.8 sets a 10.03 A overcurrent floor served by a 15 A breaker.
Where Does SunPower SPR-X21-470-COM Fall Across Listed CEC Models?
Where SunPower SPR-X21-470-COM (470.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define SunPower SPR-X21-470-COM?
Percentile placement of SunPower SPR-X21-470-COM across power density (217.6 W/m2), thermal retention, and nameplate STC wattage. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
What Do the Dataset Ranks Show for SunPower SPR-X21-470-COM?
Four critical engineering numbers homeowners and solar installers check first when reviewing SunPower SPR-X21-470-COM specifications. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
Top 23.4% STC Output
470.0 W STC (+85.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.76% Aperture Efficiency
Power density 217.6 W/m2 (1.85 percentage points above 19.91% CEC median). PTC/STC ratio: 93.2% (rank #8,924).
5 Panels Max @ -10 C (600 V)
Cold Voc reaches 101.21 V at -10 C (506.0 V string) and 103.9 V at -20 C (5 max).
18 Panels = 8,460 W STC
Occupies 38.9 m2 (419 sq ft) producing 7,884 W PTC; NEC 690.8 OCPD floor is 10.03 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 91.8 * (1 + (-0.293/100) * (-10 - 25)) = 101.21 V | OCPD = 1.56 * 6.43 = 10.03 A
Inputs from CEC Modules.csv for SunPower SPR-X21-470-COM: Voc=91.8 V, beta_Voc=-0.293%/C, Isc=6.43 A, STC=470.0 W, Area=2.16 m2.
Result: 5 panels max on 600 V (506.0 V); 18 panels for 8 kW (419 sq ft).
What Are the Published CEC Specifications for SunPower SPR-X21-470-COM?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for SunPower SPR-X21-470-COM. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 470.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 438.0 W (93.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 91.8 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 6.43 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 77.9 V / 6.03 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.293 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.76% (2.16 m2) | Array roof footprint density |
| Cell Count & Technology | 128 cells (Mono-c-Si) | Monofacial backsheet |
How Many SunPower SPR-X21-470-COM Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using SunPower SPR-X21-470-COM (470.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 13 | 6.11 kW | 302 sq ft | $1,529 | $2,586 |
| 8 kW Class | 18 | 8.46 kW | 419 sq ft | $2,117 | $3,580 |
| 10 kW Class | 22 | 10.34 kW | 512 sq ft | $2,588 | $4,376 |
Which Sibling Wattage & Trim Variants Belong to This SunPower Series?
All closely matched SunPower wattages and cosmetic trims sharing the SunPower SPR-X21-470-COM architecture. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| SunPower SPR-X21-460-COM | 460.0 W | 428.4 W | 90.5 V | 76.7 V | 21.3% |
| SunPower SPR-X21-470-COM | 470.0 W | 438.0 W | 91.8 V | 77.9 V | 21.76% |
How Many SunPower SPR-X21-470-COM Modules Fit in a Cold-Weather String?
Maximum series module counts for SunPower SPR-X21-470-COM from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 103.9 V | 5 panels | 519.5 V | 9 panels |
| -10 C (14 F) | 101.21 V | 5 panels | 506.0 V | 9 panels |
| 0 C (32 F) | 98.52 V | 6 panels | 591.1 V | 10 panels |
| 25 C (77 F STC) | 91.8 V | 6 panels | 550.8 V | 10 panels |
Which Cross-Brand Solar Modules Compare Closest to SunPower SPR-X21-470-COM?
Alternative CEC solar modules from competing brands near SunPower SPR-X21-470-COM (470.0 W), including Heliene 96M475. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Heliene 96M475 Heliene |
475.0 W | +5.0 W | 62.39 V | 18.85% | 90.5% |
| Heliene 96M460 Heliene |
460.0 W | -10.0 W | 61.79 V | 18.25% | 90.4% |
| CSI Solar Co Ltd CS3Y-470MS CSI Solar Co Ltd |
470.0 W | Tie (0 W) | 52.5 V | 20.52% | 93.5% |
| CSI Solar Co Ltd CS3Y-480P CSI Solar Co Ltd |
480.0 W | +10.0 W | 52.8 V | 20.96% | 93.2% |
What Are the Design Limits and Best-Fit Uses for SunPower SPR-X21-470-COM?
Evaluate SunPower SPR-X21-470-COM (470.0 W STC, 91.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), SunPower SPR-X21-470-COM reaches 103.9 V per panel—exceeding 5 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 419 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (419 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of SunPower SPR-X21-470-COM carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
SunPower SPR-X21-470-COM 8 kW Residential Fit
Needs 18 modules (419 sq ft) with a 15 A string OCPD, offsetting ~$2,117/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 5 panels (-10 C) or 5 panels (-20 C), or compare Heliene 96M475.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 438.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for SunPower SPR-X21-470-COM by SunPower grounded in CEC test data and NEC 690.7/690.8 limits. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
What fuse or breaker size does NEC 690.8 require for SunPower SPR-X21-470-COM?
Multiplying SunPower SPR-X21-470-COM's 6.43 A short-circuit current by 1.56 equals 10.03 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker. Check local building department permit requirements for SunPower SPR-X21-470-COM before finalizing component orders.
Can SunPower SPR-X21-470-COM pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 101.21 V cold Voc at 14 F and handles 6.43 A Isc; string inverters cap SunPower SPR-X21-470-COM at 5 panels on 600 V.
Is SunPower SPR-X21-470-COM eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of SunPower SPR-X21-470-COM rely on utility bill offset (~$2,117/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)