Manufacturer: SunPower Registry: CEC Verified Engineering Specification

SunPower SPR-X21-470-COM is a 470.0 W STC (438.0 W PTC) Mono-c-Si solar module ranking #4,967 of 21,677 CEC listings (top 23.4%; higher than 76.6% of peers). It delivers 21.76% efficiency, 91.8 V Voc at 25 C, and 101.21 V cold Voc at -10 C (5 panels max per 600 V string).

STC Wattage
470.0 W
PTC Wattage
438.0 W
Voc @ 25C
91.8 V
Efficiency
21.76%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SunPower SPR-X21-470-COM Compare Against Peer CEC Listings?

How SunPower SunPower SPR-X21-470-COM handles rooftop heat (438.0 W PTC), 8 kW sizing, and cold winter string voltage.

SunPower builds the SunPower SPR-X21-470-COM (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 217.6 W/m2 (1.85 percentage points above 19.91% CEC median). Compared against Heliene 96M475 (475.0 W), this model holds strong 93.2% PTC-to-STC heat retention (#8,924 of 21,677). Higher 91.8 V open-circuit voltage caps 600 V residential strings at 5 panels at 14 F (-10 C), while NEC 690.8 sets a 10.03 A overcurrent floor served by a 15 A breaker.

Where Does SunPower SPR-X21-470-COM Fall Across Listed CEC Models?

Where SunPower SPR-X21-470-COM (470.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where SunPower SPR-X21-470-COM (470.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSunPower SPR-X21-4: 470.0 W

What Dataset Percentiles Define SunPower SPR-X21-470-COM?

Percentile placement of SunPower SPR-X21-470-COM across power density (217.6 W/m2), thermal retention, and nameplate STC wattage. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

SunPower SPR-X21-470-COM Engineering BenchmarksPercentile comparison of SunPower SPR-X21-470-COM wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage470.0 WPTC/STC Retention93.2%Module Efficiency21.76%

What Do the Dataset Ranks Show for SunPower SPR-X21-470-COM?

Four critical engineering numbers homeowners and solar installers check first when reviewing SunPower SPR-X21-470-COM specifications. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Rank #4,967 / 21,677

Top 23.4% STC Output

470.0 W STC (+85.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #3,690

21.76% Aperture Efficiency

Power density 217.6 W/m2 (1.85 percentage points above 19.91% CEC median). PTC/STC ratio: 93.2% (rank #8,924).

NEC 690.7 Limit

5 Panels Max @ -10 C (600 V)

Cold Voc reaches 101.21 V at -10 C (506.0 V string) and 103.9 V at -20 C (5 max).

8 kW Reference Array

18 Panels = 8,460 W STC

Occupies 38.9 m2 (419 sq ft) producing 7,884 W PTC; NEC 690.8 OCPD floor is 10.03 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 91.8 * (1 + (-0.293/100) * (-10 - 25)) = 101.21 V | OCPD = 1.56 * 6.43 = 10.03 A

Inputs from CEC Modules.csv for SunPower SPR-X21-470-COM: Voc=91.8 V, beta_Voc=-0.293%/C, Isc=6.43 A, STC=470.0 W, Area=2.16 m2.

Result: 5 panels max on 600 V (506.0 V); 18 panels for 8 kW (419 sq ft).

What Are the Published CEC Specifications for SunPower SPR-X21-470-COM?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for SunPower SPR-X21-470-COM. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Official California Energy Commission (NREL SAM) test parameters for SunPower SPR-X21-470-COM.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 470.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 438.0 W (93.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 91.8 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 6.43 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 77.9 V / 6.03 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.293 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.76% (2.16 m2) Array roof footprint density
Cell Count & Technology 128 cells (Mono-c-Si) Monofacial backsheet

How Many SunPower SPR-X21-470-COM Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using SunPower SPR-X21-470-COM (470.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 13 6.11 kW 302 sq ft $1,529 $2,586
8 kW Class 18 8.46 kW 419 sq ft $2,117 $3,580
10 kW Class 22 10.34 kW 512 sq ft $2,588 $4,376

Which Sibling Wattage & Trim Variants Belong to This SunPower Series?

All closely matched SunPower wattages and cosmetic trims sharing the SunPower SPR-X21-470-COM architecture. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Sibling CEC listings grouped into the SunPower SPR-X21-470-COM wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
SunPower SPR-X21-460-COM 460.0 W 428.4 W 90.5 V 76.7 V 21.3%
SunPower SPR-X21-470-COM 470.0 W 438.0 W 91.8 V 77.9 V 21.76%

How Many SunPower SPR-X21-470-COM Modules Fit in a Cold-Weather String?

Maximum series module counts for SunPower SPR-X21-470-COM from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=91.8V and beta_Voc=-0.293%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 103.9 V 5 panels 519.5 V 9 panels
-10 C (14 F) 101.21 V 5 panels 506.0 V 9 panels
0 C (32 F) 98.52 V 6 panels 591.1 V 10 panels
25 C (77 F STC) 91.8 V 6 panels 550.8 V 10 panels

Which Cross-Brand Solar Modules Compare Closest to SunPower SPR-X21-470-COM?

Alternative CEC solar modules from competing brands near SunPower SPR-X21-470-COM (470.0 W), including Heliene 96M475. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Heliene 96M475
Heliene
475.0 W +5.0 W 62.39 V 18.85% 90.5%
Heliene 96M460
Heliene
460.0 W -10.0 W 61.79 V 18.25% 90.4%
CSI Solar Co Ltd CS3Y-470MS
CSI Solar Co Ltd
470.0 W Tie (0 W) 52.5 V 20.52% 93.5%
CSI Solar Co Ltd CS3Y-480P
CSI Solar Co Ltd
480.0 W +10.0 W 52.8 V 20.96% 93.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for SunPower SPR-X21-470-COM?

Evaluate SunPower SPR-X21-470-COM (470.0 W STC, 91.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), SunPower SPR-X21-470-COM reaches 103.9 V per panel—exceeding 5 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 18 panels for an 8 kW build require 419 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (419 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of SunPower SPR-X21-470-COM carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

SunPower SPR-X21-470-COM 8 kW Residential Fit

Needs 18 modules (419 sq ft) with a 15 A string OCPD, offsetting ~$2,117/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 5 panels (-10 C) or 5 panels (-20 C), or compare Heliene 96M475.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 438.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for SunPower SPR-X21-470-COM by SunPower grounded in CEC test data and NEC 690.7/690.8 limits. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

What fuse or breaker size does NEC 690.8 require for SunPower SPR-X21-470-COM?

Multiplying SunPower SPR-X21-470-COM's 6.43 A short-circuit current by 1.56 equals 10.03 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker. Check local building department permit requirements for SunPower SPR-X21-470-COM before finalizing component orders.

Can SunPower SPR-X21-470-COM pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 101.21 V cold Voc at 14 F and handles 6.43 A Isc; string inverters cap SunPower SPR-X21-470-COM at 5 panels on 600 V.

Is SunPower SPR-X21-470-COM eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of SunPower SPR-X21-470-COM rely on utility bill offset (~$2,117/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.