CSI Solar Co Ltd CS3Y-485MS is a 485.0 W STC (453.8 W PTC) Mono-c-Si solar module ranking #4,730 of 21,677 CEC listings (top 22.2%; higher than 77.8% of peers). It delivers 21.18% efficiency, 53.1 V Voc at 25 C, and 57.88 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 485.0 W
- PTC Wattage
- 453.8 W
- Voc @ 25C
- 53.1 V
- Efficiency
- 21.18%
How Does CSI Solar Co Ltd CS3Y-485MS Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for CSI Solar Co Ltd CS3Y-485MS (Mono-c-Si) residential solar systems.
Homeowners evaluating CSI Solar Co Ltd CS3Y-485MS need 13 panels for 6 kW or 17 panels (419 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 17 panels (419 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.257%/C) pushes open-circuit voltage to 57.88 V at 14 F and 59.24 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does CSI Solar Co Ltd CS3Y-485MS Fall Across Listed CEC Models?
Comparison of CSI Solar Co Ltd CS3Y-485MS (485.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define CSI Solar Co Ltd CS3Y-485MS?
Relative ranking of CSI Solar Co Ltd CS3Y-485MS across nameplate watts, 93.6% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for CSI Solar Co Ltd CS3Y-485MS?
Summary of CSI Solar Co Ltd CS3Y-485MS output rank, 8 kW array size (17 panels), efficiency rating, and 600 V string limit.
Top 22.2% STC Output
485.0 W STC (+100.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.18% Aperture Efficiency
Power density 211.8 W/m2 (1.27 percentage points above 19.91% CEC median). PTC/STC ratio: 93.6% (rank #6,726).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 57.88 V at -10 C (578.8 V string) and 59.24 V at -20 C (10 max).
17 Panels = 8,245 W STC
Occupies 38.9 m2 (419 sq ft) producing 7,715 W PTC; NEC 690.8 OCPD floor is 18.13 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 53.1 * (1 + (-0.257/100) * (-10 - 25)) = 57.88 V | OCPD = 1.56 * 11.62 = 18.13 A
Inputs from CEC Modules.csv for CSI Solar Co Ltd CS3Y-485MS: Voc=53.1 V, beta_Voc=-0.257%/C, Isc=11.62 A, STC=485.0 W, Area=2.29 m2.
Result: 10 panels max on 600 V (578.8 V); 17 panels for 8 kW (419 sq ft).
What Are the Published CEC Specifications for CSI Solar Co Ltd CS3Y-485MS?
Complete CEC test sheet for CSI Solar Co Ltd CS3Y-485MS including Isc (11.62 A), Voc (53.1 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 485.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 453.8 W (93.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 53.1 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 11.62 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 44.4 V / 10.94 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.257 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.18% (2.29 m2) | Array roof footprint density |
| Cell Count & Technology | 78 cells (Mono-c-Si) | Monofacial backsheet |
How Many CSI Solar Co Ltd CS3Y-485MS Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using CSI Solar Co Ltd CS3Y-485MS.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 13 | 6.3 kW | 320 sq ft | $1,577 | $2,666 |
| 8 kW Class | 17 | 8.24 kW | 419 sq ft | $2,062 | $3,487 |
| 10 kW Class | 21 | 10.19 kW | 518 sq ft | $2,550 | $4,313 |
Which Sibling Wattage & Trim Variants Belong to This CSI Solar Co Ltd Series?
Related CSI Solar Co Ltd power steps and black/silver trims consolidated into this CSI Solar Co Ltd CS3Y-485MS series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS3Y-475MS | 475.0 W | 444.2 W | 52.7 V | 44.0 V | 20.74% |
| CSI Solar Co Ltd CS3Y-480MS | 480.0 W | 449.0 W | 52.9 V | 44.2 V | 20.96% |
| CSI Solar Co Ltd CS3Y-485MS | 485.0 W | 453.8 W | 53.1 V | 44.4 V | 21.18% |
| CSI Solar Co Ltd CS3Y-490MS | 490.0 W | 458.6 W | 53.3 V | 44.6 V | 21.4% |
How Many CSI Solar Co Ltd CS3Y-485MS Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for CSI Solar Co Ltd CS3Y-485MS (53.1 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 59.24 V | 10 panels | 592.4 V | 16 panels |
| -10 C (14 F) | 57.88 V | 10 panels | 578.8 V | 17 panels |
| 0 C (32 F) | 56.51 V | 10 panels | 565.1 V | 17 panels |
| 25 C (77 F STC) | 53.1 V | 11 panels | 584.1 V | 18 panels |
Which Cross-Brand Solar Modules Compare Closest to CSI Solar Co Ltd CS3Y-485MS?
Four comparable CEC modules such as Heliene 132HC-485 M10 SL (485.0 W) for side-by-side solar quote checks. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Heliene 132HC-485 M10 SL Heliene |
485.0 W | Tie (0 W) | 45.77 V | 21.18% | 94.3% |
| Heliene 144HC-460 Heliene |
460.0 W | -25.0 W | 51.26 V | 20.81% | 92.4% |
| Auxin Solar AXN10M485B Auxin Solar |
485.0 W | Tie (0 W) | 43.98 V | 22.56% | 92.0% |
| Auxin Solar AXN10M485W Auxin Solar |
485.0 W | Tie (0 W) | 43.98 V | 22.56% | 91.8% |
What Are the Design Limits and Best-Fit Uses for CSI Solar Co Ltd CS3Y-485MS?
Evaluate CSI Solar Co Ltd CS3Y-485MS (485.0 W STC, 53.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), CSI Solar Co Ltd CS3Y-485MS reaches 59.24 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 17 panels for an 8 kW build require 419 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 17 panels (419 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of CSI Solar Co Ltd CS3Y-485MS carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
CSI Solar Co Ltd CS3Y-485MS 8 kW Residential Fit
Needs 17 modules (419 sq ft) with a 20 A string OCPD, offsetting ~$2,062/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Heliene 132HC-485 M10 SL.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 453.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for CSI Solar Co Ltd CS3Y-485MS by CSI Solar Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
Why is CSI Solar Co Ltd CS3Y-485MS PTC wattage (453.8 W) lower than STC (485.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 453.8 W PTC (93.6% retention) across CSI Solar Co Ltd CS3Y-485MS's 2.29 m2 aperture.
Who should skip CSI Solar Co Ltd CS3Y-485MS on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 17 CSI Solar Co Ltd CS3Y-485MS panels (419 sq ft) leave unusable roof gaps vs. Heliene 132HC-485 M10 SL.
What is the 1,000 V commercial string limit for CSI Solar Co Ltd CS3Y-485MS?
On 1,000 V commercial inverters at -10 C (57.88 V cold Voc), CSI Solar Co Ltd CS3Y-485MS fits up to 17 panels per series string.