AXITEC AC-450MH/144V is a 450.0 W STC (416.1 W PTC) Mono-c-Si solar module ranking #5,679 of 21,677 CEC listings (top 27.8%; higher than 72.2% of peers). It delivers 21.23% efficiency, 50.0 V Voc at 25 C, and 54.88 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 450.0 W
- PTC Wattage
- 416.1 W
- Voc @ 25C
- 50.0 V
- Efficiency
- 21.23%
How Does AXITEC AC-450MH/144V Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for AXITEC AC-450MH/144V (Mono-c-Si) residential solar systems.
AXITEC AC-450MH/144V delivers 212.3 W/m2 (1.32 percentage points above 19.91% CEC median) and strong 92.5% PTC-to-STC heat retention (#12,531 of 21,677), placing it as a modern high-density residential and light-commercial module well-proportioned for residential pitched roofs needing 18 panels (411 sq ft) for an 8 kW array. At -4 F (-20 C), string voltage climbs to 56.28 V per unit, capping 600 V circuits at 10 panels. Compare specs directly with Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-450W (450.0 W).
Where Does AXITEC AC-450MH/144V Fall Across Listed CEC Models?
Comparison of AXITEC AC-450MH/144V (450.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
What Dataset Percentiles Define AXITEC AC-450MH/144V?
Relative ranking of AXITEC AC-450MH/144V across nameplate watts, 92.5% PTC thermal ratio, and module aperture efficiency. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
What Do the Dataset Ranks Show for AXITEC AC-450MH/144V?
Summary of AXITEC AC-450MH/144V output rank, 8 kW array size (18 panels), efficiency rating, and 600 V string limit.
Top 27.8% STC Output
450.0 W STC (+65.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.23% Aperture Efficiency
Power density 212.3 W/m2 (1.32 percentage points above 19.91% CEC median). PTC/STC ratio: 92.5% (rank #12,531).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 54.88 V at -10 C (548.8 V string) and 56.28 V at -20 C (10 max).
18 Panels = 8,100 W STC
Occupies 38.2 m2 (411 sq ft) producing 7,490 W PTC; NEC 690.8 OCPD floor is 17.89 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 50.0 * (1 + (-0.279/100) * (-10 - 25)) = 54.88 V | OCPD = 1.56 * 11.47 = 17.89 A
Inputs from CEC Modules.csv for AXITEC AC-450MH/144V: Voc=50.0 V, beta_Voc=-0.279%/C, Isc=11.47 A, STC=450.0 W, Area=2.12 m2.
Result: 10 panels max on 600 V (548.8 V); 18 panels for 8 kW (411 sq ft).
What Are the Published CEC Specifications for AXITEC AC-450MH/144V?
Complete CEC test sheet for AXITEC AC-450MH/144V including Isc (11.47 A), Voc (50.0 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 450.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 416.1 W (92.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 50.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 11.47 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 41.4 V / 10.88 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.279 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.23% (2.12 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many AXITEC AC-450MH/144V Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using AXITEC AC-450MH/144V.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.3 kW | 319 sq ft | $1,577 | $2,666 |
| 8 kW Class | 18 | 8.1 kW | 411 sq ft | $2,027 | $3,428 |
| 10 kW Class | 23 | 10.35 kW | 525 sq ft | $2,591 | $4,380 |
How Many AXITEC AC-450MH/144V Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for AXITEC AC-450MH/144V (50.0 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 56.28 V | 10 panels | 562.8 V | 17 panels |
| -10 C (14 F) | 54.88 V | 10 panels | 548.8 V | 18 panels |
| 0 C (32 F) | 53.49 V | 11 panels | 588.4 V | 18 panels |
| 25 C (77 F STC) | 50.0 V | 12 panels | 600.0 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to AXITEC AC-450MH/144V?
Four comparable CEC modules such as Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-450W (450.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-450W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
450.0 W | Tie (0 W) | 50.0 V | 21.23% | 92.5% |
| Dehui Solar Power (Vietnam) CoLtd DH-M772W 450W Dehui Solar Power (Vietnam) CoLtd |
450.0 W | Tie (0 W) | 50.0 V | 21.23% | 92.5% |
| FreeVolt ECP-PVGRAF-144HC-450W FreeVolt |
450.0 W | Tie (0 W) | 50.0 V | 21.23% | 92.5% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-BHC-450W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
450.0 W | Tie (0 W) | 49.6 V | 21.03% | 92.6% |
What Are the Design Limits and Best-Fit Uses for AXITEC AC-450MH/144V?
Evaluate AXITEC AC-450MH/144V (450.0 W STC, 50.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), AXITEC AC-450MH/144V reaches 56.28 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 411 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (411 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of AXITEC AC-450MH/144V carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
AXITEC AC-450MH/144V 8 kW Residential Fit
Needs 18 modules (411 sq ft) with a 20 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-450W.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 416.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for AXITEC AC-450MH/144V by AXITEC grounded in CEC test data and NEC 690.7/690.8 limits.
How many AXITEC AC-450MH/144V panels fit on a 600 V winter solar string?
At -10 C (14 F), AXITEC AC-450MH/144V cold Voc rises from 50.0 V to 54.88 V (beta_Voc -0.279%/C), capping a 600 V string at 10 panels (548.8 V).
How much roof area does an 8 kW array of AXITEC AC-450MH/144V need?
An 8 kW DC system uses 18 AXITEC AC-450MH/144V modules (8,100 W STC / 7,490 W PTC), covering roughly 411 sq ft and saving ~$2,027/yr at 18.54 c/kWh.
How does AXITEC AC-450MH/144V compare against Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-450W?
AXITEC AC-450MH/144V outputs 450.0 W STC (50.0 V Voc, rank #5,679 of 21,677), while Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-450W delivers 450.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)