SunPower SPR-X20-445-COM is a 445.0 W STC (412.7 W PTC) Mono-c-Si solar module ranking #6,028 of 21,677 CEC listings (top 29.6%; higher than 70.4% of peers). It delivers 20.58% efficiency, 90.5 V Voc at 25 C, and 99.72 V cold Voc at -10 C (6 panels max per 600 V string).
- STC Wattage
- 445.0 W
- PTC Wattage
- 412.7 W
- Voc @ 25C
- 90.5 V
- Efficiency
- 20.58%
How Does SunPower SPR-X20-445-COM Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for SunPower SPR-X20-445-COM (Mono-c-Si) residential solar systems. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
Homeowners evaluating SunPower SPR-X20-445-COM need 14 panels for 6 kW or 18 panels (419 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 18 panels (419 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.291%/C) pushes open-circuit voltage to 99.72 V at 14 F and 102.35 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does SunPower SPR-X20-445-COM Fall Across Listed CEC Models?
Comparison of SunPower SPR-X20-445-COM (445.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
What Dataset Percentiles Define SunPower SPR-X20-445-COM?
Relative ranking of SunPower SPR-X20-445-COM across nameplate watts, 92.7% PTC thermal ratio, and module aperture efficiency. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
What Do the Dataset Ranks Show for SunPower SPR-X20-445-COM?
Summary of SunPower SPR-X20-445-COM output rank, 8 kW array size (18 panels), efficiency rating, and 600 V string limit.
Top 29.6% STC Output
445.0 W STC (+60.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.58% Aperture Efficiency
Power density 205.8 W/m2 (0.67 percentage points above 19.91% CEC median). PTC/STC ratio: 92.7% (rank #11,468).
6 Panels Max @ -10 C (600 V)
Cold Voc reaches 99.72 V at -10 C (598.3 V string) and 102.35 V at -20 C (5 max).
18 Panels = 8,010 W STC
Occupies 38.9 m2 (419 sq ft) producing 7,429 W PTC; NEC 690.8 OCPD floor is 9.69 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 90.5 * (1 + (-0.291/100) * (-10 - 25)) = 99.72 V | OCPD = 1.56 * 6.21 = 9.69 A
Inputs from CEC Modules.csv for SunPower SPR-X20-445-COM: Voc=90.5 V, beta_Voc=-0.291%/C, Isc=6.21 A, STC=445.0 W, Area=2.162 m2.
Result: 6 panels max on 600 V (598.3 V); 18 panels for 8 kW (419 sq ft).
What Are the Published CEC Specifications for SunPower SPR-X20-445-COM?
Complete CEC test sheet for SunPower SPR-X20-445-COM including Isc (6.21 A), Voc (90.5 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 445.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 412.7 W (92.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 90.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 6.21 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 76.7 V / 5.8 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.291 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.58% (2.162 m2) | Array roof footprint density |
| Cell Count & Technology | 128 cells (Mono-c-Si) | Monofacial backsheet |
How Many SunPower SPR-X20-445-COM Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using SunPower SPR-X20-445-COM.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.23 kW | 326 sq ft | $1,559 | $2,637 |
| 8 kW Class | 18 | 8.01 kW | 419 sq ft | $2,005 | $3,390 |
| 10 kW Class | 23 | 10.23 kW | 535 sq ft | $2,560 | $4,330 |
How Many SunPower SPR-X20-445-COM Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for SunPower SPR-X20-445-COM (90.5 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 102.35 V | 5 panels | 511.8 V | 9 panels |
| -10 C (14 F) | 99.72 V | 6 panels | 598.3 V | 10 panels |
| 0 C (32 F) | 97.08 V | 6 panels | 582.5 V | 10 panels |
| 25 C (77 F STC) | 90.5 V | 6 panels | 543.0 V | 11 panels |
Which Cross-Brand Solar Modules Compare Closest to SunPower SPR-X20-445-COM?
Four comparable CEC modules such as CSI Solar Co Ltd CS3Y-445P (445.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS3Y-445P CSI Solar Co Ltd |
445.0 W | Tie (0 W) | 51.4 V | 19.43% | 93.0% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
440.0 W | -5.0 W | 49.6 V | 20.75% | 92.4% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-BHC-440W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
440.0 W | -5.0 W | 49.3 V | 20.56% | 92.6% |
| Apollo Renewables Inc Apollo-M672BH-440TW Apollo Renewables Inc |
440.0 W | -5.0 W | 49.2 V | 20.47% | 93.4% |
What Are the Design Limits and Best-Fit Uses for SunPower SPR-X20-445-COM?
Evaluate SunPower SPR-X20-445-COM (445.0 W STC, 90.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), SunPower SPR-X20-445-COM reaches 102.35 V per panel—exceeding 5 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 419 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (419 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of SunPower SPR-X20-445-COM carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
SunPower SPR-X20-445-COM 8 kW Residential Fit
Needs 18 modules (419 sq ft) with a 15 A string OCPD, offsetting ~$2,005/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 6 panels (-10 C) or 5 panels (-20 C), or compare CSI Solar Co Ltd CS3Y-445P.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 412.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for SunPower SPR-X20-445-COM by SunPower grounded in CEC test data and NEC 690.7/690.8 limits. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
Why is SunPower SPR-X20-445-COM PTC wattage (412.7 W) lower than STC (445.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 412.7 W PTC (92.7% retention) across SunPower SPR-X20-445-COM's 2.162 m2 aperture.
Who should skip SunPower SPR-X20-445-COM on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 18 SunPower SPR-X20-445-COM panels (419 sq ft) leave unusable roof gaps vs. CSI Solar Co Ltd CS3Y-445P.
What is the 1,000 V commercial string limit for SunPower SPR-X20-445-COM?
On 1,000 V commercial inverters at -10 C (99.72 V cold Voc), SunPower SPR-X20-445-COM fits up to 10 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting SunPower SPR-X20-445-COM.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)