SunPower SPR-MAX3-430 is a 430.0 W STC (408.5 W PTC) Mono-c-Si solar module ranking #7,266 of 21,677 CEC listings (top 35.2%; higher than 64.8% of peers). It delivers 22.63% efficiency, 81.36 V Voc at 25 C, and 87.99 V cold Voc at -10 C (6 panels max per 600 V string).
- STC Wattage
- 430.0 W
- PTC Wattage
- 408.5 W
- Voc @ 25C
- 81.36 V
- Efficiency
- 22.63%
How Does SunPower SPR-MAX3-430 Compare Against Peer CEC Listings?
Solar engineering breakdown for SunPower SPR-MAX3-430: PTC thermal retention, roof footprint, and cold Voc string bounds. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
Across 5,889 Mono-c-Si listings from SunPower and peers, SunPower SPR-MAX3-430 stands 20.0 W above the 410.0 W Mono-c-Si median and strong 95.0% PTC-to-STC heat retention (#1,106 of 21,677). Sizing 6 kW (14 panels) to 10 kW (24 panels) yields $1,507-$2,583/yr in baseline US bill offset. Higher 81.36 V open-circuit voltage caps 600 V residential strings at 6 panels at 14 F (-10 C).
Where Does SunPower SPR-MAX3-430 Fall Across Listed CEC Models?
Distribution marker showing SunPower SPR-MAX3-430 (430.0 W) relative to the 385.0 W all-CEC solar panel median. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
What Dataset Percentiles Define SunPower SPR-MAX3-430?
Dataset percentiles tracking SunPower SPR-MAX3-430 power output, thermal retention ratio, and aperture efficiency against 21,677 models. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
What Do the Dataset Ranks Show for SunPower SPR-MAX3-430?
Benchmark highlights for SunPower SPR-MAX3-430 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
Top 35.2% STC Output
430.0 W STC (+45.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
22.63% Aperture Efficiency
Power density 226.3 W/m2 (2.72 percentage points above 19.91% CEC median). PTC/STC ratio: 95.0% (rank #1,106).
6 Panels Max @ -10 C (600 V)
Cold Voc reaches 87.99 V at -10 C (527.9 V string) and 89.89 V at -20 C (6 max).
19 Panels = 8,170 W STC
Occupies 36.1 m2 (389 sq ft) producing 7,762 W PTC; NEC 690.8 OCPD floor is 10.25 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 81.36 * (1 + (-0.233/100) * (-10 - 25)) = 87.99 V | OCPD = 1.56 * 6.57 = 10.25 A
Inputs from CEC Modules.csv for SunPower SPR-MAX3-430: Voc=81.36 V, beta_Voc=-0.233%/C, Isc=6.57 A, STC=430.0 W, Area=1.9 m2.
Result: 6 panels max on 600 V (527.9 V); 19 panels for 8 kW (389 sq ft).
What Are the Published CEC Specifications for SunPower SPR-MAX3-430?
Official CEC datasheet figures for SunPower SPR-MAX3-430 (Mono-c-Si) used in utility interconnection and permit reviews. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 430.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 408.5 W (95.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 81.36 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 6.57 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 70.42 V / 6.11 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.233 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 22.63% (1.9 m2) | Array roof footprint density |
| Cell Count & Technology | 112 cells (Mono-c-Si) | Monofacial backsheet |
How Many SunPower SPR-MAX3-430 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many SunPower SPR-MAX3-430 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.02 kW | 286 sq ft | $1,507 | $2,548 |
| 8 kW Class | 19 | 8.17 kW | 389 sq ft | $2,045 | $3,458 |
| 10 kW Class | 24 | 10.32 kW | 491 sq ft | $2,583 | $4,368 |
Which Sibling Wattage & Trim Variants Belong to This SunPower Series?
Consolidated SunPower wattage variants sharing the SunPower SPR-MAX3-430 mechanical and cell layout. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| SunPower SPR-MAX3-425 | 425.0 W | 403.6 W | 81.32 V | 70.01 V | 22.37% |
| SunPower SPR-MAX3-430 | 430.0 W | 408.5 W | 81.36 V | 70.42 V | 22.63% |
| SunPower SPR-MAX3-435 | 435.0 W | 413.3 W | 81.4 V | 70.8 V | 22.89% |
How Many SunPower SPR-MAX3-430 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on SunPower SPR-MAX3-430 (87.99 V at 14 F). Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 89.89 V | 6 panels | 539.3 V | 11 panels |
| -10 C (14 F) | 87.99 V | 6 panels | 527.9 V | 11 panels |
| 0 C (32 F) | 86.1 V | 6 panels | 516.6 V | 11 panels |
| 25 C (77 F STC) | 81.36 V | 7 panels | 569.5 V | 12 panels |
Which Cross-Brand Solar Modules Compare Closest to SunPower SPR-MAX3-430?
Competing CEC solar panels closest to SunPower SPR-MAX3-430 in nameplate wattage and Voc, starting with Aptos Solar Technology LLC DNA-144-MF26-435W {Blk}.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Aptos Solar Technology LLC DNA-144-MF26-435W {Blk} Aptos Solar Technology LLC |
435.0 W | +5.0 W | 49.7 V | 20.71% | 91.8% |
| Aptos Solar Technology LLC DNA-144-MF26-435W {Wht} Aptos Solar Technology LLC |
435.0 W | +5.0 W | 49.7 V | 20.71% | 92.8% |
| CertainTeed CT435HC11-06 CertainTeed |
435.0 W | +5.0 W | 49.7 V | 20.71% | 91.8% |
| AXITEC AC-435MH/144V AXITEC |
435.0 W | +5.0 W | 49.4 V | 20.52% | 92.4% |
What Are the Design Limits and Best-Fit Uses for SunPower SPR-MAX3-430?
Evaluate SunPower SPR-MAX3-430 (430.0 W STC, 81.36 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), SunPower SPR-MAX3-430 reaches 89.89 V per panel—exceeding 6 panels in series voids 600 V inverter warranties.
- Footprint constraint: 19 panels for an 8 kW build require 389 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (389 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of SunPower SPR-MAX3-430 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
SunPower SPR-MAX3-430 8 kW Residential Fit
Needs 19 modules (389 sq ft) with a 15 A string OCPD, offsetting ~$2,045/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 6 panels (-10 C) or 6 panels (-20 C), or compare Aptos Solar Technology LLC DNA-144-MF26-435W {Blk}.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 408.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for SunPower SPR-MAX3-430 by SunPower grounded in CEC test data and NEC 690.7/690.8 limits. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
What fuse or breaker size does NEC 690.8 require for SunPower SPR-MAX3-430?
Multiplying SunPower SPR-MAX3-430's 6.57 A short-circuit current by 1.56 equals 10.25 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker. Check local building department permit requirements for SunPower SPR-MAX3-430 before finalizing component orders.
Can SunPower SPR-MAX3-430 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 87.99 V cold Voc at 14 F and handles 6.57 A Isc; string inverters cap SunPower SPR-MAX3-430 at 6 panels on 600 V.
Is SunPower SPR-MAX3-430 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of SunPower SPR-MAX3-430 rely on utility bill offset (~$2,045/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)