Skip to main content
WireAndSun
Calculators
CEC PV Module

SunPower SPR-MAX3-430 — CEC Solar Module Specifications

Manufacturer: SunPower Registry: CEC Verified Engineering Specification

SunPower SPR-MAX3-430 is a 430.0 W STC (408.5 W PTC) Mono-c-Si solar module ranking #7,266 of 21,677 CEC listings (top 35.2%; higher than 64.8% of peers). It delivers 22.63% efficiency, 81.36 V Voc at 25 C, and 87.99 V cold Voc at -10 C (6 panels max per 600 V string).

STC Wattage
430.0 W
PTC Wattage
408.5 W
Voc @ 25C
81.36 V
Efficiency
22.63%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SunPower SPR-MAX3-430 Compare Against Peer CEC Listings?

Solar engineering breakdown for SunPower SPR-MAX3-430: PTC thermal retention, roof footprint, and cold Voc string bounds. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Across 5,889 Mono-c-Si listings from SunPower and peers, SunPower SPR-MAX3-430 stands 20.0 W above the 410.0 W Mono-c-Si median and strong 95.0% PTC-to-STC heat retention (#1,106 of 21,677). Sizing 6 kW (14 panels) to 10 kW (24 panels) yields $1,507-$2,583/yr in baseline US bill offset. Higher 81.36 V open-circuit voltage caps 600 V residential strings at 6 panels at 14 F (-10 C).

Where Does SunPower SPR-MAX3-430 Fall Across Listed CEC Models?

Distribution marker showing SunPower SPR-MAX3-430 (430.0 W) relative to the 385.0 W all-CEC solar panel median. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where SunPower SPR-MAX3-430 (430.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSunPower SPR-MAX3-: 430.0 W

What Dataset Percentiles Define SunPower SPR-MAX3-430?

Dataset percentiles tracking SunPower SPR-MAX3-430 power output, thermal retention ratio, and aperture efficiency against 21,677 models. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

SunPower SPR-MAX3-430 Engineering BenchmarksPercentile comparison of SunPower SPR-MAX3-430 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage430.0 WPTC/STC Retention95.0%Module Efficiency22.63%

What Do the Dataset Ranks Show for SunPower SPR-MAX3-430?

Benchmark highlights for SunPower SPR-MAX3-430 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Rank #7,266 / 21,677

Top 35.2% STC Output

430.0 W STC (+45.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #1,792

22.63% Aperture Efficiency

Power density 226.3 W/m2 (2.72 percentage points above 19.91% CEC median). PTC/STC ratio: 95.0% (rank #1,106).

NEC 690.7 Limit

6 Panels Max @ -10 C (600 V)

Cold Voc reaches 87.99 V at -10 C (527.9 V string) and 89.89 V at -20 C (6 max).

8 kW Reference Array

19 Panels = 8,170 W STC

Occupies 36.1 m2 (389 sq ft) producing 7,762 W PTC; NEC 690.8 OCPD floor is 10.25 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 81.36 * (1 + (-0.233/100) * (-10 - 25)) = 87.99 V | OCPD = 1.56 * 6.57 = 10.25 A

Inputs from CEC Modules.csv for SunPower SPR-MAX3-430: Voc=81.36 V, beta_Voc=-0.233%/C, Isc=6.57 A, STC=430.0 W, Area=1.9 m2.

Result: 6 panels max on 600 V (527.9 V); 19 panels for 8 kW (389 sq ft).

What Are the Published CEC Specifications for SunPower SPR-MAX3-430?

Official CEC datasheet figures for SunPower SPR-MAX3-430 (Mono-c-Si) used in utility interconnection and permit reviews. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Official California Energy Commission (NREL SAM) test parameters for SunPower SPR-MAX3-430.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 430.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 408.5 W (95.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 81.36 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 6.57 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 70.42 V / 6.11 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.233 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 22.63% (1.9 m2) Array roof footprint density
Cell Count & Technology 112 cells (Mono-c-Si) Monofacial backsheet

How Many SunPower SPR-MAX3-430 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many SunPower SPR-MAX3-430 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.02 kW 286 sq ft $1,507 $2,548
8 kW Class 19 8.17 kW 389 sq ft $2,045 $3,458
10 kW Class 24 10.32 kW 491 sq ft $2,583 $4,368

Which Sibling Wattage & Trim Variants Belong to This SunPower Series?

Consolidated SunPower wattage variants sharing the SunPower SPR-MAX3-430 mechanical and cell layout. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Sibling CEC listings grouped into the SunPower SPR-MAX3-430 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
SunPower SPR-MAX3-425 425.0 W 403.6 W 81.32 V 70.01 V 22.37%
SunPower SPR-MAX3-430 430.0 W 408.5 W 81.36 V 70.42 V 22.63%
SunPower SPR-MAX3-435 435.0 W 413.3 W 81.4 V 70.8 V 22.89%

How Many SunPower SPR-MAX3-430 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on SunPower SPR-MAX3-430 (87.99 V at 14 F). Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Computed from Voc=81.36V and beta_Voc=-0.233%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 89.89 V 6 panels 539.3 V 11 panels
-10 C (14 F) 87.99 V 6 panels 527.9 V 11 panels
0 C (32 F) 86.1 V 6 panels 516.6 V 11 panels
25 C (77 F STC) 81.36 V 7 panels 569.5 V 12 panels

Which Cross-Brand Solar Modules Compare Closest to SunPower SPR-MAX3-430?

Competing CEC solar panels closest to SunPower SPR-MAX3-430 in nameplate wattage and Voc, starting with Aptos Solar Technology LLC DNA-144-MF26-435W {Blk}.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Aptos Solar Technology LLC DNA-144-MF26-435W {Blk}
Aptos Solar Technology LLC
435.0 W +5.0 W 49.7 V 20.71% 91.8%
Aptos Solar Technology LLC DNA-144-MF26-435W {Wht}
Aptos Solar Technology LLC
435.0 W +5.0 W 49.7 V 20.71% 92.8%
CertainTeed CT435HC11-06
CertainTeed
435.0 W +5.0 W 49.7 V 20.71% 91.8%
AXITEC AC-435MH/144V
AXITEC
435.0 W +5.0 W 49.4 V 20.52% 92.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for SunPower SPR-MAX3-430?

Evaluate SunPower SPR-MAX3-430 (430.0 W STC, 81.36 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), SunPower SPR-MAX3-430 reaches 89.89 V per panel—exceeding 6 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 19 panels for an 8 kW build require 389 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (389 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of SunPower SPR-MAX3-430 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

SunPower SPR-MAX3-430 8 kW Residential Fit

Needs 19 modules (389 sq ft) with a 15 A string OCPD, offsetting ~$2,045/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 6 panels (-10 C) or 6 panels (-20 C), or compare Aptos Solar Technology LLC DNA-144-MF26-435W {Blk}.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 408.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for SunPower SPR-MAX3-430 by SunPower grounded in CEC test data and NEC 690.7/690.8 limits. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

What fuse or breaker size does NEC 690.8 require for SunPower SPR-MAX3-430?

Multiplying SunPower SPR-MAX3-430's 6.57 A short-circuit current by 1.56 equals 10.25 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker. Check local building department permit requirements for SunPower SPR-MAX3-430 before finalizing component orders.

Can SunPower SPR-MAX3-430 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 87.99 V cold Voc at 14 F and handles 6.57 A Isc; string inverters cap SunPower SPR-MAX3-430 at 6 panels on 600 V.

Is SunPower SPR-MAX3-430 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of SunPower SPR-MAX3-430 rely on utility bill offset (~$2,045/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.