SunPower SPR-MAX3-415 is a 415.0 W STC (393.9 W PTC) Mono-c-Si solar module ranking #8,199 of 21,677 CEC listings (top 39.4%; higher than 60.6% of peers). It delivers 21.84% efficiency, 81.23 V Voc at 25 C, and 87.85 V cold Voc at -10 C (6 panels max per 600 V string).

STC Wattage
415.0 W
PTC Wattage
393.9 W
Voc @ 25C
81.23 V
Efficiency
21.84%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SunPower SPR-MAX3-415 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for SunPower SPR-MAX3-415 (Mono-c-Si) residential solar systems. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Homeowners evaluating SunPower SPR-MAX3-415 need 15 panels for 6 kW or 20 panels (409 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 20 panels (409 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.233%/C) pushes open-circuit voltage to 87.85 V at 14 F and 89.75 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does SunPower SPR-MAX3-415 Fall Across Listed CEC Models?

Comparison of SunPower SPR-MAX3-415 (415.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where SunPower SPR-MAX3-415 (415.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSunPower SPR-MAX3-: 415.0 W

What Dataset Percentiles Define SunPower SPR-MAX3-415?

Relative ranking of SunPower SPR-MAX3-415 across nameplate watts, 94.9% PTC thermal ratio, and module aperture efficiency. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

SunPower SPR-MAX3-415 Engineering BenchmarksPercentile comparison of SunPower SPR-MAX3-415 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage415.0 WPTC/STC Retention94.9%Module Efficiency21.84%

What Do the Dataset Ranks Show for SunPower SPR-MAX3-415?

Summary of SunPower SPR-MAX3-415 output rank, 8 kW array size (20 panels), efficiency rating, and 600 V string limit.

Rank #8,199 / 21,677

Top 39.4% STC Output

415.0 W STC (+30.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #3,491

21.84% Aperture Efficiency

Power density 218.4 W/m2 (1.93 percentage points above 19.91% CEC median). PTC/STC ratio: 94.9% (rank #1,466).

NEC 690.7 Limit

6 Panels Max @ -10 C (600 V)

Cold Voc reaches 87.85 V at -10 C (527.1 V string) and 89.75 V at -20 C (6 max).

8 kW Reference Array

20 Panels = 8,300 W STC

Occupies 38.0 m2 (409 sq ft) producing 7,878 W PTC; NEC 690.8 OCPD floor is 10.22 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 81.23 * (1 + (-0.233/100) * (-10 - 25)) = 87.85 V | OCPD = 1.56 * 6.55 = 10.22 A

Inputs from CEC Modules.csv for SunPower SPR-MAX3-415: Voc=81.23 V, beta_Voc=-0.233%/C, Isc=6.55 A, STC=415.0 W, Area=1.9 m2.

Result: 6 panels max on 600 V (527.1 V); 20 panels for 8 kW (409 sq ft).

What Are the Published CEC Specifications for SunPower SPR-MAX3-415?

Complete CEC test sheet for SunPower SPR-MAX3-415 including Isc (6.55 A), Voc (81.23 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for SunPower SPR-MAX3-415.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 415.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 393.9 W (94.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 81.23 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 6.55 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 69.2 V / 6.0 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.233 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.84% (1.9 m2) Array roof footprint density
Cell Count & Technology 112 cells (Mono-c-Si) Monofacial backsheet

How Many SunPower SPR-MAX3-415 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using SunPower SPR-MAX3-415.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.22 kW 307 sq ft $1,557 $2,632
8 kW Class 20 8.3 kW 409 sq ft $2,077 $3,513
10 kW Class 25 10.38 kW 511 sq ft $2,598 $4,393

Which Sibling Wattage & Trim Variants Belong to This SunPower Series?

Related SunPower power steps and black/silver trims consolidated into this SunPower SPR-MAX3-415 series guide. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Sibling CEC listings grouped into the SunPower SPR-MAX3-415 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
SunPower SPR-MAX3-400 400.0 W 379.4 W 81.09 V 67.98 V 21.05%
SunPower SPR-MAX3-400-BLK 400.0 W 379.4 W 81.26 V 69.55 V 21.05%
SunPower SPR-MAX3-410-BLK 410.0 W 389.1 W 81.4 V 70.4 V 21.58%
SunPower SPR-MAX3-415 415.0 W 393.9 W 81.23 V 69.2 V 21.84%
SunPower SPR-MAX3-415-BLK 415.0 W 393.9 W 81.4 V 70.8 V 21.84%
SunPower SPR-MAX3-420 420.0 W 398.8 W 81.27 V 69.61 V 22.11%
SunPower SPR-MAX3-420-BLK 420.0 W 398.8 W 81.5 V 71.3 V 22.11%

How Many SunPower SPR-MAX3-415 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for SunPower SPR-MAX3-415 (81.23 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=81.23V and beta_Voc=-0.233%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 89.75 V 6 panels 538.5 V 11 panels
-10 C (14 F) 87.85 V 6 panels 527.1 V 11 panels
0 C (32 F) 85.96 V 6 panels 515.8 V 11 panels
25 C (77 F STC) 81.23 V 7 panels 568.6 V 12 panels

Which Cross-Brand Solar Modules Compare Closest to SunPower SPR-MAX3-415?

Four comparable CEC modules such as CSI Solar Co Ltd CS1Y-410MS (410.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS1Y-410MS
CSI Solar Co Ltd
410.0 W -5.0 W 52.7 V 21.03% 94.1%
Auxin Solar AXNG1M410B
Auxin Solar
410.0 W -5.0 W 49.47 V 20.92% 93.4%
Auxin Solar AXNG1M410W
Auxin Solar
410.0 W -5.0 W 49.47 V 20.92% 93.3%
Dehui Solar Power (Vietnam) CoLtd DH-M872W 410W
Dehui Solar Power (Vietnam) CoLtd
410.0 W -5.0 W 49.4 V 21.47% 92.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for SunPower SPR-MAX3-415?

Evaluate SunPower SPR-MAX3-415 (415.0 W STC, 81.23 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), SunPower SPR-MAX3-415 reaches 89.75 V per panel—exceeding 6 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 409 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (409 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of SunPower SPR-MAX3-415 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

SunPower SPR-MAX3-415 8 kW Residential Fit

Needs 20 modules (409 sq ft) with a 15 A string OCPD, offsetting ~$2,077/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 6 panels (-10 C) or 6 panels (-20 C), or compare CSI Solar Co Ltd CS1Y-410MS.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 393.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for SunPower SPR-MAX3-415 by SunPower grounded in CEC test data and NEC 690.7/690.8 limits. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Why is SunPower SPR-MAX3-415 PTC wattage (393.9 W) lower than STC (415.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 393.9 W PTC (94.9% retention) across SunPower SPR-MAX3-415's 1.9 m2 aperture.

Who should skip SunPower SPR-MAX3-415 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 20 SunPower SPR-MAX3-415 panels (409 sq ft) leave unusable roof gaps vs. CSI Solar Co Ltd CS1Y-410MS.

What is the 1,000 V commercial string limit for SunPower SPR-MAX3-415?

On 1,000 V commercial inverters at -10 C (87.85 V cold Voc), SunPower SPR-MAX3-415 fits up to 11 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting SunPower SPR-MAX3-415.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.