Skip to main content
WireAndSun
Calculators
CEC PV Module

SunPower SPR-A415-COM — CEC Solar Module Specifications

Manufacturer: SunPower Registry: CEC Verified Engineering Specification

SunPower SPR-A415-COM is a 415.0 W STC (384.9 W PTC) Mono-c-Si solar module ranking #8,199 of 21,677 CEC listings (top 39.4%; higher than 60.6% of peers). It delivers 20.44% efficiency, 54.0 V Voc at 25 C, and 58.55 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
415.0 W
PTC Wattage
384.9 W
Voc @ 25C
54.0 V
Efficiency
20.44%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SunPower SPR-A415-COM Compare Against Peer CEC Listings?

How SunPower SunPower SPR-A415-COM handles rooftop heat (384.9 W PTC), 8 kW sizing, and cold winter string voltage.

SunPower builds the SunPower SPR-A415-COM (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 204.4 W/m2 (0.53 percentage points above 19.91% CEC median). Compared against CSI Solar Co Ltd CS1Y-410MS (410.0 W), this model holds strong 92.7% PTC-to-STC heat retention (#11,468 of 21,677). Higher 54.0 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C), while NEC 690.8 sets a 17.0 A overcurrent floor served by a 20 A breaker.

Where Does SunPower SPR-A415-COM Fall Across Listed CEC Models?

Where SunPower SPR-A415-COM (415.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where SunPower SPR-A415-COM (415.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSunPower SPR-A415-: 415.0 W

What Dataset Percentiles Define SunPower SPR-A415-COM?

Percentile placement of SunPower SPR-A415-COM across power density (204.4 W/m2), thermal retention, and nameplate STC wattage. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

SunPower SPR-A415-COM Engineering BenchmarksPercentile comparison of SunPower SPR-A415-COM wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage415.0 WPTC/STC Retention92.7%Module Efficiency20.44%

What Do the Dataset Ranks Show for SunPower SPR-A415-COM?

Four critical engineering numbers homeowners and solar installers check first when reviewing SunPower SPR-A415-COM specifications. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Rank #8,199 / 21,677

Top 39.4% STC Output

415.0 W STC (+30.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #8,857

20.44% Aperture Efficiency

Power density 204.4 W/m2 (0.53 percentage points above 19.91% CEC median). PTC/STC ratio: 92.7% (rank #11,468).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 58.55 V at -10 C (585.5 V string) and 59.86 V at -20 C (10 max).

8 kW Reference Array

20 Panels = 8,300 W STC

Occupies 40.6 m2 (437 sq ft) producing 7,698 W PTC; NEC 690.8 OCPD floor is 17.0 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 54.0 * (1 + (-0.241/100) * (-10 - 25)) = 58.55 V | OCPD = 1.56 * 10.9 = 17.0 A

Inputs from CEC Modules.csv for SunPower SPR-A415-COM: Voc=54.0 V, beta_Voc=-0.241%/C, Isc=10.9 A, STC=415.0 W, Area=2.03 m2.

Result: 10 panels max on 600 V (585.5 V); 20 panels for 8 kW (437 sq ft).

What Are the Published CEC Specifications for SunPower SPR-A415-COM?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for SunPower SPR-A415-COM. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Official California Energy Commission (NREL SAM) test parameters for SunPower SPR-A415-COM.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 415.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 384.9 W (92.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 54.0 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.9 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 44.9 V / 10.1 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.241 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.44% (2.03 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many SunPower SPR-A415-COM Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using SunPower SPR-A415-COM (415.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.22 kW 328 sq ft $1,557 $2,632
8 kW Class 20 8.3 kW 437 sq ft $2,077 $3,513
10 kW Class 25 10.38 kW 546 sq ft $2,598 $4,393

Which Sibling Wattage & Trim Variants Belong to This SunPower Series?

All closely matched SunPower wattages and cosmetic trims sharing the SunPower SPR-A415-COM architecture. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Sibling CEC listings grouped into the SunPower SPR-A415-COM wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
SunPower SPR-A400-COM 400.0 W 370.6 W 52.1 V 43.3 V 19.7%
SunPower SPR-A405-COM 405.0 W 375.4 W 52.7 V 43.4 V 19.95%
SunPower SPR-A410-COM 410.0 W 380.1 W 53.4 V 44.4 V 20.2%
SunPower SPR-A415-COM 415.0 W 384.9 W 54.0 V 44.9 V 20.44%
SunPower SPR-A420-COM 420.0 W 389.7 W 54.7 V 45.4 V 20.69%

How Many SunPower SPR-A415-COM Modules Fit in a Cold-Weather String?

Maximum series module counts for SunPower SPR-A415-COM from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=54.0V and beta_Voc=-0.241%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 59.86 V 10 panels 598.6 V 16 panels
-10 C (14 F) 58.55 V 10 panels 585.5 V 17 panels
0 C (32 F) 57.25 V 10 panels 572.5 V 17 panels
25 C (77 F STC) 54.0 V 11 panels 594.0 V 18 panels

Which Cross-Brand Solar Modules Compare Closest to SunPower SPR-A415-COM?

Alternative CEC solar modules from competing brands near SunPower SPR-A415-COM (415.0 W), including CSI Solar Co Ltd CS1Y-410MS.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS1Y-410MS
CSI Solar Co Ltd
410.0 W -5.0 W 52.7 V 21.03% 94.1%
Auxin Solar AXNG1M410B
Auxin Solar
410.0 W -5.0 W 49.47 V 20.92% 93.4%
Auxin Solar AXNG1M410W
Auxin Solar
410.0 W -5.0 W 49.47 V 20.92% 93.3%
Dehui Solar Power (Vietnam) CoLtd DH-M872W 410W
Dehui Solar Power (Vietnam) CoLtd
410.0 W -5.0 W 49.4 V 21.47% 92.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for SunPower SPR-A415-COM?

Evaluate SunPower SPR-A415-COM (415.0 W STC, 54.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), SunPower SPR-A415-COM reaches 59.86 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 437 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (437 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of SunPower SPR-A415-COM carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

SunPower SPR-A415-COM 8 kW Residential Fit

Needs 20 modules (437 sq ft) with a 20 A string OCPD, offsetting ~$2,077/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare CSI Solar Co Ltd CS1Y-410MS.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 384.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for SunPower SPR-A415-COM by SunPower grounded in CEC test data and NEC 690.7/690.8 limits. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

What fuse or breaker size does NEC 690.8 require for SunPower SPR-A415-COM?

Multiplying SunPower SPR-A415-COM's 10.9 A short-circuit current by 1.56 equals 17.0 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker. Check local building department permit requirements for SunPower SPR-A415-COM before finalizing component orders.

Can SunPower SPR-A415-COM pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 58.55 V cold Voc at 14 F and handles 10.9 A Isc; string inverters cap SunPower SPR-A415-COM at 10 panels on 600 V.

Is SunPower SPR-A415-COM eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of SunPower SPR-A415-COM rely on utility bill offset (~$2,077/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.