SunPower SPR-A390-BLK is a 390.0 W STC (366.4 W PTC) Mono-c-Si solar module ranking #10,321 of 21,677 CEC listings (top 49.5%; higher than 50.5% of peers). It delivers 20.86% efficiency, 48.07 V Voc at 25 C, and 52.07 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 390.0 W
- PTC Wattage
- 366.4 W
- Voc @ 25C
- 48.07 V
- Efficiency
- 20.86%
How Does SunPower SPR-A390-BLK Compare Against Peer CEC Listings?
How SunPower SunPower SPR-A390-BLK handles rooftop heat (366.4 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, SunPower SPR-A390-BLK exhibits 10.82 A short-circuit current, requiring a 16.88 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #10,321 of 21,677 (20.0 W below the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 39.3 m2 for an 8 kW system (26 panels for 10 kW). Higher 48.07 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).
Where Does SunPower SPR-A390-BLK Fall Across Listed CEC Models?
Where SunPower SPR-A390-BLK (390.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define SunPower SPR-A390-BLK?
Percentile placement of SunPower SPR-A390-BLK across power density (208.6 W/m2), thermal retention, and nameplate STC wattage. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
What Do the Dataset Ranks Show for SunPower SPR-A390-BLK?
Four critical engineering numbers homeowners and solar installers check first when reviewing SunPower SPR-A390-BLK specifications. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
Top 49.5% STC Output
390.0 W STC (+5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.86% Aperture Efficiency
Power density 208.6 W/m2 (0.95 percentage points above 19.91% CEC median). PTC/STC ratio: 93.9% (rank #5,210).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 52.07 V at -10 C (572.8 V string) and 53.22 V at -20 C (11 max).
21 Panels = 8,190 W STC
Occupies 39.3 m2 (423 sq ft) producing 7,694 W PTC; NEC 690.8 OCPD floor is 16.88 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 48.07 * (1 + (-0.238/100) * (-10 - 25)) = 52.07 V | OCPD = 1.56 * 10.82 = 16.88 A
Inputs from CEC Modules.csv for SunPower SPR-A390-BLK: Voc=48.07 V, beta_Voc=-0.238%/C, Isc=10.82 A, STC=390.0 W, Area=1.87 m2.
Result: 11 panels max on 600 V (572.8 V); 21 panels for 8 kW (423 sq ft).
What Are the Published CEC Specifications for SunPower SPR-A390-BLK?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for SunPower SPR-A390-BLK. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 390.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 366.4 W (93.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 48.07 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.82 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 39.28 V / 10.05 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.238 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.86% (1.87 m2) | Array roof footprint density |
| Cell Count & Technology | 66 cells (Mono-c-Si) | Monofacial backsheet |
How Many SunPower SPR-A390-BLK Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using SunPower SPR-A390-BLK (390.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.24 kW | 322 sq ft | $1,562 | $2,641 |
| 8 kW Class | 21 | 8.19 kW | 423 sq ft | $2,050 | $3,466 |
| 10 kW Class | 26 | 10.14 kW | 523 sq ft | $2,538 | $4,292 |
Which Sibling Wattage & Trim Variants Belong to This SunPower Series?
All closely matched SunPower wattages and cosmetic trims sharing the SunPower SPR-A390-BLK architecture. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| SunPower SPR-A380-BLK | 380.0 W | 356.8 W | 48.01 V | 38.79 V | 20.32% |
| SunPower SPR-A385-BLK | 385.0 W | 361.6 W | 48.04 V | 39.04 V | 20.59% |
| SunPower SPR-A390 | 390.0 W | 365.3 W | 48.0 V | 39.0 V | 20.86% |
| SunPower SPR-A390-BLK | 390.0 W | 366.4 W | 48.07 V | 39.28 V | 20.86% |
| SunPower SPR-A395 | 395.0 W | 370.1 W | 47.5 V | 39.5 V | 21.12% |
| SunPower SPR-A395-BLK | 395.0 W | 371.2 W | 48.1 V | 39.53 V | 21.12% |
How Many SunPower SPR-A390-BLK Modules Fit in a Cold-Weather String?
Maximum series module counts for SunPower SPR-A390-BLK from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 53.22 V | 11 panels | 585.4 V | 18 panels |
| -10 C (14 F) | 52.07 V | 11 panels | 572.8 V | 19 panels |
| 0 C (32 F) | 50.93 V | 11 panels | 560.2 V | 19 panels |
| 25 C (77 F STC) | 48.07 V | 12 panels | 576.8 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to SunPower SPR-A390-BLK?
Alternative CEC solar modules from competing brands near SunPower SPR-A390-BLK (390.0 W), including CSI Solar Co Ltd CS3U-390MS.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS3U-390MS CSI Solar Co Ltd |
390.0 W | Tie (0 W) | 48.2 V | 20.31% | 93.2% |
| CSI Solar Co Ltd CS3W-390P CSI Solar Co Ltd |
390.0 W | Tie (0 W) | 46.8 V | 18.22% | 92.4% |
| AXITEC AC-385MH/144S AXITEC |
385.0 W | -5.0 W | 48.0 V | 19.41% | 92.9% |
| AXITEC AC-385MH/144V AXITEC |
385.0 W | -5.0 W | 48.0 V | 19.41% | 92.9% |
What Are the Design Limits and Best-Fit Uses for SunPower SPR-A390-BLK?
Evaluate SunPower SPR-A390-BLK (390.0 W STC, 48.07 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), SunPower SPR-A390-BLK reaches 53.22 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 423 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (423 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of SunPower SPR-A390-BLK carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
SunPower SPR-A390-BLK 8 kW Residential Fit
Needs 21 modules (423 sq ft) with a 20 A string OCPD, offsetting ~$2,050/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare CSI Solar Co Ltd CS3U-390MS.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 366.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for SunPower SPR-A390-BLK by SunPower grounded in CEC test data and NEC 690.7/690.8 limits. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
Why is SunPower SPR-A390-BLK PTC wattage (366.4 W) lower than STC (390.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 366.4 W PTC (93.9% retention) across SunPower SPR-A390-BLK's 1.87 m2 aperture.
Who should skip SunPower SPR-A390-BLK on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 21 SunPower SPR-A390-BLK panels (423 sq ft) leave unusable roof gaps vs. CSI Solar Co Ltd CS3U-390MS.
What is the 1,000 V commercial string limit for SunPower SPR-A390-BLK?
On 1,000 V commercial inverters at -10 C (52.07 V cold Voc), SunPower SPR-A390-BLK fits up to 19 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting SunPower SPR-A390-BLK.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)