Manufacturer: SunPower Registry: CEC Verified Engineering Specification

SunPower SPR-A390-BLK is a 390.0 W STC (366.4 W PTC) Mono-c-Si solar module ranking #10,321 of 21,677 CEC listings (top 49.5%; higher than 50.5% of peers). It delivers 20.86% efficiency, 48.07 V Voc at 25 C, and 52.07 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
390.0 W
PTC Wattage
366.4 W
Voc @ 25C
48.07 V
Efficiency
20.86%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SunPower SPR-A390-BLK Compare Against Peer CEC Listings?

How SunPower SunPower SPR-A390-BLK handles rooftop heat (366.4 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, SunPower SPR-A390-BLK exhibits 10.82 A short-circuit current, requiring a 16.88 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #10,321 of 21,677 (20.0 W below the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 39.3 m2 for an 8 kW system (26 panels for 10 kW). Higher 48.07 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).

Where Does SunPower SPR-A390-BLK Fall Across Listed CEC Models?

Where SunPower SPR-A390-BLK (390.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where SunPower SPR-A390-BLK (390.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSunPower SPR-A390-: 390.0 W

What Dataset Percentiles Define SunPower SPR-A390-BLK?

Percentile placement of SunPower SPR-A390-BLK across power density (208.6 W/m2), thermal retention, and nameplate STC wattage. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

SunPower SPR-A390-BLK Engineering BenchmarksPercentile comparison of SunPower SPR-A390-BLK wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage390.0 WPTC/STC Retention93.9%Module Efficiency20.86%

What Do the Dataset Ranks Show for SunPower SPR-A390-BLK?

Four critical engineering numbers homeowners and solar installers check first when reviewing SunPower SPR-A390-BLK specifications. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Rank #10,321 / 21,677

Top 49.5% STC Output

390.0 W STC (+5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #7,024

20.86% Aperture Efficiency

Power density 208.6 W/m2 (0.95 percentage points above 19.91% CEC median). PTC/STC ratio: 93.9% (rank #5,210).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 52.07 V at -10 C (572.8 V string) and 53.22 V at -20 C (11 max).

8 kW Reference Array

21 Panels = 8,190 W STC

Occupies 39.3 m2 (423 sq ft) producing 7,694 W PTC; NEC 690.8 OCPD floor is 16.88 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.07 * (1 + (-0.238/100) * (-10 - 25)) = 52.07 V | OCPD = 1.56 * 10.82 = 16.88 A

Inputs from CEC Modules.csv for SunPower SPR-A390-BLK: Voc=48.07 V, beta_Voc=-0.238%/C, Isc=10.82 A, STC=390.0 W, Area=1.87 m2.

Result: 11 panels max on 600 V (572.8 V); 21 panels for 8 kW (423 sq ft).

What Are the Published CEC Specifications for SunPower SPR-A390-BLK?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for SunPower SPR-A390-BLK. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Official California Energy Commission (NREL SAM) test parameters for SunPower SPR-A390-BLK.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 390.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 366.4 W (93.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 48.07 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.82 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 39.28 V / 10.05 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.238 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.86% (1.87 m2) Array roof footprint density
Cell Count & Technology 66 cells (Mono-c-Si) Monofacial backsheet

How Many SunPower SPR-A390-BLK Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using SunPower SPR-A390-BLK (390.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.24 kW 322 sq ft $1,562 $2,641
8 kW Class 21 8.19 kW 423 sq ft $2,050 $3,466
10 kW Class 26 10.14 kW 523 sq ft $2,538 $4,292

Which Sibling Wattage & Trim Variants Belong to This SunPower Series?

All closely matched SunPower wattages and cosmetic trims sharing the SunPower SPR-A390-BLK architecture. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Sibling CEC listings grouped into the SunPower SPR-A390-BLK wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
SunPower SPR-A380-BLK 380.0 W 356.8 W 48.01 V 38.79 V 20.32%
SunPower SPR-A385-BLK 385.0 W 361.6 W 48.04 V 39.04 V 20.59%
SunPower SPR-A390 390.0 W 365.3 W 48.0 V 39.0 V 20.86%
SunPower SPR-A390-BLK 390.0 W 366.4 W 48.07 V 39.28 V 20.86%
SunPower SPR-A395 395.0 W 370.1 W 47.5 V 39.5 V 21.12%
SunPower SPR-A395-BLK 395.0 W 371.2 W 48.1 V 39.53 V 21.12%

How Many SunPower SPR-A390-BLK Modules Fit in a Cold-Weather String?

Maximum series module counts for SunPower SPR-A390-BLK from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=48.07V and beta_Voc=-0.238%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 53.22 V 11 panels 585.4 V 18 panels
-10 C (14 F) 52.07 V 11 panels 572.8 V 19 panels
0 C (32 F) 50.93 V 11 panels 560.2 V 19 panels
25 C (77 F STC) 48.07 V 12 panels 576.8 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to SunPower SPR-A390-BLK?

Alternative CEC solar modules from competing brands near SunPower SPR-A390-BLK (390.0 W), including CSI Solar Co Ltd CS3U-390MS.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS3U-390MS
CSI Solar Co Ltd
390.0 W Tie (0 W) 48.2 V 20.31% 93.2%
CSI Solar Co Ltd CS3W-390P
CSI Solar Co Ltd
390.0 W Tie (0 W) 46.8 V 18.22% 92.4%
AXITEC AC-385MH/144S
AXITEC
385.0 W -5.0 W 48.0 V 19.41% 92.9%
AXITEC AC-385MH/144V
AXITEC
385.0 W -5.0 W 48.0 V 19.41% 92.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for SunPower SPR-A390-BLK?

Evaluate SunPower SPR-A390-BLK (390.0 W STC, 48.07 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), SunPower SPR-A390-BLK reaches 53.22 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 21 panels for an 8 kW build require 423 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (423 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of SunPower SPR-A390-BLK carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

SunPower SPR-A390-BLK 8 kW Residential Fit

Needs 21 modules (423 sq ft) with a 20 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare CSI Solar Co Ltd CS3U-390MS.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 366.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for SunPower SPR-A390-BLK by SunPower grounded in CEC test data and NEC 690.7/690.8 limits. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Why is SunPower SPR-A390-BLK PTC wattage (366.4 W) lower than STC (390.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 366.4 W PTC (93.9% retention) across SunPower SPR-A390-BLK's 1.87 m2 aperture.

Who should skip SunPower SPR-A390-BLK on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 21 SunPower SPR-A390-BLK panels (423 sq ft) leave unusable roof gaps vs. CSI Solar Co Ltd CS3U-390MS.

What is the 1,000 V commercial string limit for SunPower SPR-A390-BLK?

On 1,000 V commercial inverters at -10 C (52.07 V cold Voc), SunPower SPR-A390-BLK fits up to 19 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting SunPower SPR-A390-BLK.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.