Manufacturer: AXITEC Registry: CEC Verified Engineering Specification

AXITEC AC-385MH/144S is a 385.0 W STC (357.5 W PTC) Mono-c-Si solar module ranking #10,723 of 21,677 CEC listings (at all-CEC median; higher than 49.1% of peers). It delivers 19.41% efficiency, 48.0 V Voc at 25 C, and 52.62 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
385.0 W
PTC Wattage
357.5 W
Voc @ 25C
48.0 V
Efficiency
19.41%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does AXITEC AC-385MH/144S Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for AXITEC AC-385MH/144S (Mono-c-Si) residential solar systems.

Homeowners evaluating AXITEC AC-385MH/144S need 16 panels for 6 kW or 21 panels (448 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 21 panels (448 sq ft). Under NEC 690.7(A), beta_Voc (-0.275%/C) pushes open-circuit voltage to 52.62 V at 14 F and 53.94 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does AXITEC AC-385MH/144S Fall Across Listed CEC Models?

Comparison of AXITEC AC-385MH/144S (385.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where AXITEC AC-385MH/144S (385.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCAXITEC AC-385MH/14: 385.0 W

What Dataset Percentiles Define AXITEC AC-385MH/144S?

Relative ranking of AXITEC AC-385MH/144S across nameplate watts, 92.9% PTC thermal ratio, and module aperture efficiency. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

AXITEC AC-385MH/144S Engineering BenchmarksPercentile comparison of AXITEC AC-385MH/144S wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage385.0 WPTC/STC Retention92.9%Module Efficiency19.41%

What Do the Dataset Ranks Show for AXITEC AC-385MH/144S?

Summary of AXITEC AC-385MH/144S output rank, 8 kW array size (21 panels), efficiency rating, and 600 V string limit.

Rank #10,723 / 21,677

385.0 W STC · Higher Than 49.1%

385.0 W STC (equal to all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #12,393

19.41% Aperture Efficiency

Power density 194.1 W/m2 (0.50 percentage points below 19.91% CEC median). PTC/STC ratio: 92.9% (rank #10,348).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 52.62 V at -10 C (578.8 V string) and 53.94 V at -20 C (11 max).

8 kW Reference Array

21 Panels = 8,085 W STC

Occupies 41.7 m2 (448 sq ft) producing 7,508 W PTC; NEC 690.8 OCPD floor is 15.72 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.0 * (1 + (-0.275/100) * (-10 - 25)) = 52.62 V | OCPD = 1.56 * 10.08 = 15.72 A

Inputs from CEC Modules.csv for AXITEC AC-385MH/144S: Voc=48.0 V, beta_Voc=-0.275%/C, Isc=10.08 A, STC=385.0 W, Area=1.984 m2.

Result: 11 panels max on 600 V (578.8 V); 21 panels for 8 kW (448 sq ft).

What Are the Published CEC Specifications for AXITEC AC-385MH/144S?

Complete CEC test sheet for AXITEC AC-385MH/144S including Isc (10.08 A), Voc (48.0 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for AXITEC AC-385MH/144S.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 385.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 357.5 W (92.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 48.0 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.08 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 40.21 V / 9.58 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.275 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 19.41% (1.984 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many AXITEC AC-385MH/144S Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using AXITEC AC-385MH/144S.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.16 kW 342 sq ft $1,542 $2,607
8 kW Class 21 8.09 kW 448 sq ft $2,025 $3,424
10 kW Class 26 10.01 kW 555 sq ft $2,505 $4,236

Which Sibling Wattage & Trim Variants Belong to This AXITEC Series?

Related AXITEC power steps and black/silver trims consolidated into this AXITEC AC-385MH/144S series guide. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Sibling CEC listings grouped into the AXITEC AC-385MH/144S wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
AXITEC AC-375MH/144S 375.0 W 348.0 W 47.61 V 39.81 V 18.9%
AXITEC AC-380MH/144S 380.0 W 352.7 W 47.8 V 40.02 V 19.15%
AXITEC AC-385MH/144S 385.0 W 357.5 W 48.0 V 40.21 V 19.41%
AXITEC AC-390MH/144S 390.0 W 364.2 W 48.18 V 40.37 V 19.7%
AXITEC AC-395MH/144S 395.0 W 369.0 W 48.37 V 40.55 V 19.95%

How Many AXITEC AC-385MH/144S Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for AXITEC AC-385MH/144S (48.0 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=48.0V and beta_Voc=-0.275%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 53.94 V 11 panels 593.3 V 18 panels
-10 C (14 F) 52.62 V 11 panels 578.8 V 19 panels
0 C (32 F) 51.3 V 11 panels 564.3 V 19 panels
25 C (77 F STC) 48.0 V 12 panels 576.0 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to AXITEC AC-385MH/144S?

Four comparable CEC modules such as CSI Solar Co Ltd CS3U-385P (385.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS3U-385P
CSI Solar Co Ltd
385.0 W Tie (0 W) 48.0 V 20.05% 93.2%
Boviet Solar Technology Co Ltd BVM6612M-385L-H
Boviet Solar Technology Co Ltd
385.0 W Tie (0 W) 48.45 V 19.35% 93.2%
Boviet Solar Technology Co Ltd BVM6612M-385L-H-HC
Boviet Solar Technology Co Ltd
385.0 W Tie (0 W) 48.45 V 18.97% 93.5%
Boviet Solar Technology Co Ltd BVM6612M-385-H
Boviet Solar Technology Co Ltd
385.0 W Tie (0 W) 48.5 V 19.85% 93.1%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for AXITEC AC-385MH/144S?

Evaluate AXITEC AC-385MH/144S (385.0 W STC, 48.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), AXITEC AC-385MH/144S reaches 53.94 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 21 panels for an 8 kW build require 448 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 21 panels (448 sq ft).
  • 2026 tax credit baseline: cash residential installs of AXITEC AC-385MH/144S carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

AXITEC AC-385MH/144S 8 kW Residential Fit

Needs 21 modules (448 sq ft) with a 20 A string OCPD, offsetting ~$2,025/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare CSI Solar Co Ltd CS3U-385P.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 357.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for AXITEC AC-385MH/144S by AXITEC grounded in CEC test data and NEC 690.7/690.8 limits.

Why is AXITEC AC-385MH/144S PTC wattage (357.5 W) lower than STC (385.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 357.5 W PTC (92.9% retention) across AXITEC AC-385MH/144S's 1.984 m2 aperture.

Who should skip AXITEC AC-385MH/144S on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 21 AXITEC AC-385MH/144S panels (448 sq ft) leave unusable roof gaps vs. CSI Solar Co Ltd CS3U-385P.

What is the 1,000 V commercial string limit for AXITEC AC-385MH/144S?

On 1,000 V commercial inverters at -10 C (52.62 V cold Voc), AXITEC AC-385MH/144S fits up to 19 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting AXITEC AC-385MH/144S.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.