CSI Solar Co Ltd CS3U-385P is a 385.0 W STC (358.8 W PTC) Multi-c-Si solar module ranking #10,723 of 21,677 CEC listings (at all-CEC median; higher than 49.1% of peers). It delivers 20.05% efficiency, 48.0 V Voc at 25 C, and 52.94 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 385.0 W
- PTC Wattage
- 358.8 W
- Voc @ 25C
- 48.0 V
- Efficiency
- 20.05%
How Does CSI Solar Co Ltd CS3U-385P Compare Against Peer CEC Listings?
How CSI Solar Co Ltd CSI Solar Co Ltd CS3U-385P handles rooftop heat (358.8 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, CSI Solar Co Ltd CS3U-385P exhibits 10.07 A short-circuit current, requiring a 15.71 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #10,723 of 21,677 (106.2 W above the 278.8 W Multi-c-Si median), this compact residential or specialty off-grid module covers 40.3 m2 for an 8 kW system (26 panels for 10 kW). Higher 48.0 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).
Where Does CSI Solar Co Ltd CS3U-385P Fall Across Listed CEC Models?
Where CSI Solar Co Ltd CS3U-385P (385.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define CSI Solar Co Ltd CS3U-385P?
Percentile placement of CSI Solar Co Ltd CS3U-385P across power density (200.5 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for CSI Solar Co Ltd CS3U-385P?
Four critical engineering numbers homeowners and solar installers check first when reviewing CSI Solar Co Ltd CS3U-385P specifications.
385.0 W STC · Higher Than 49.1%
385.0 W STC (equal to all-CEC median) vs 278.8 W Multi-c-Si median.
20.05% Aperture Efficiency
Power density 200.5 W/m2 (0.14 percentage points above 19.91% CEC median). PTC/STC ratio: 93.2% (rank #8,924).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 52.94 V at -10 C (582.3 V string) and 54.35 V at -20 C (11 max).
21 Panels = 8,085 W STC
Occupies 40.3 m2 (434 sq ft) producing 7,535 W PTC; NEC 690.8 OCPD floor is 15.71 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 48.0 * (1 + (-0.294/100) * (-10 - 25)) = 52.94 V | OCPD = 1.56 * 10.07 = 15.71 A
Inputs from CEC Modules.csv for CSI Solar Co Ltd CS3U-385P: Voc=48.0 V, beta_Voc=-0.294%/C, Isc=10.07 A, STC=385.0 W, Area=1.92 m2.
Result: 11 panels max on 600 V (582.3 V); 21 panels for 8 kW (434 sq ft).
What Are the Published CEC Specifications for CSI Solar Co Ltd CS3U-385P?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for CSI Solar Co Ltd CS3U-385P.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 385.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 358.8 W (93.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 48.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.07 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 40.6 V / 9.5 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.294 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.05% (1.92 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Multi-c-Si) | Monofacial backsheet |
How Many CSI Solar Co Ltd CS3U-385P Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using CSI Solar Co Ltd CS3U-385P (385.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.16 kW | 331 sq ft | $1,542 | $2,607 |
| 8 kW Class | 21 | 8.09 kW | 434 sq ft | $2,025 | $3,424 |
| 10 kW Class | 26 | 10.01 kW | 537 sq ft | $2,505 | $4,236 |
Which Sibling Wattage & Trim Variants Belong to This CSI Solar Co Ltd Series?
All closely matched CSI Solar Co Ltd wattages and cosmetic trims sharing the CSI Solar Co Ltd CS3U-385P architecture.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS3U-375P | 375.0 W | 349.2 W | 47.6 V | 40.2 V | 19.53% |
| CSI Solar Co Ltd CS3U-380P | 380.0 W | 354.0 W | 47.8 V | 40.4 V | 19.79% |
| CSI Solar Co Ltd CS3U-385P | 385.0 W | 358.8 W | 48.0 V | 40.6 V | 20.05% |
| CSI Solar Co Ltd CS3U-390P | 390.0 W | 363.6 W | 48.2 V | 40.8 V | 20.31% |
| CSI Solar Co Ltd CS3U-395P | 395.0 W | 368.4 W | 48.4 V | 41.0 V | 20.57% |
How Many CSI Solar Co Ltd CS3U-385P Modules Fit in a Cold-Weather String?
Maximum series module counts for CSI Solar Co Ltd CS3U-385P from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 54.35 V | 11 panels | 597.9 V | 18 panels |
| -10 C (14 F) | 52.94 V | 11 panels | 582.3 V | 18 panels |
| 0 C (32 F) | 51.53 V | 11 panels | 566.8 V | 19 panels |
| 25 C (77 F STC) | 48.0 V | 12 panels | 576.0 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to CSI Solar Co Ltd CS3U-385P?
Alternative CEC solar modules from competing brands near CSI Solar Co Ltd CS3U-385P (385.0 W), including AXITEC AC-385MH/144S.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| AXITEC AC-385MH/144S AXITEC |
385.0 W | Tie (0 W) | 48.0 V | 19.41% | 92.9% |
| AXITEC AC-385MH/144V AXITEC |
385.0 W | Tie (0 W) | 48.0 V | 19.41% | 92.9% |
| Boviet Solar Technology Co Ltd BVM6612M-385L-H Boviet Solar Technology Co Ltd |
385.0 W | Tie (0 W) | 48.45 V | 19.35% | 93.2% |
| Boviet Solar Technology Co Ltd BVM6612M-385L-H-HC Boviet Solar Technology Co Ltd |
385.0 W | Tie (0 W) | 48.45 V | 18.97% | 93.5% |
What Are the Design Limits and Best-Fit Uses for CSI Solar Co Ltd CS3U-385P?
Evaluate CSI Solar Co Ltd CS3U-385P (385.0 W STC, 48.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), CSI Solar Co Ltd CS3U-385P reaches 54.35 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 434 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 21 panels (434 sq ft).
- 2026 tax credit baseline: cash residential installs of CSI Solar Co Ltd CS3U-385P carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
CSI Solar Co Ltd CS3U-385P 8 kW Residential Fit
Needs 21 modules (434 sq ft) with a 20 A string OCPD, offsetting ~$2,025/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare AXITEC AC-385MH/144S.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 358.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for CSI Solar Co Ltd CS3U-385P by CSI Solar Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
Why is CSI Solar Co Ltd CS3U-385P PTC wattage (358.8 W) lower than STC (385.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 358.8 W PTC (93.2% retention) across CSI Solar Co Ltd CS3U-385P's 1.92 m2 aperture.
Who should skip CSI Solar Co Ltd CS3U-385P on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 21 CSI Solar Co Ltd CS3U-385P panels (434 sq ft) leave unusable roof gaps vs. AXITEC AC-385MH/144S.
What is the 1,000 V commercial string limit for CSI Solar Co Ltd CS3U-385P?
On 1,000 V commercial inverters at -10 C (52.94 V cold Voc), CSI Solar Co Ltd CS3U-385P fits up to 18 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)