Skip to main content
WireAndSun
Calculators
CEC PV Module

SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108 — CEC Solar Module Specifications

Manufacturer: SOLAREVER TECNOLOG A DE AMERICA SA DE CV Registry: CEC Verified Engineering Specification

SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108 is a 415.0 W STC (384.8 W PTC) Mono-c-Si solar module ranking #8,199 of 21,677 CEC listings (top 39.4%; higher than 60.6% of peers). It delivers 20.96% efficiency, 37.25 V Voc at 25 C, and 41.08 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
415.0 W
PTC Wattage
384.8 W
Voc @ 25C
37.25 V
Efficiency
20.96%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108 Compare Against Peer CEC Listings?

How SOLAREVER TECNOLOG A DE AMERICA SA DE CV SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108 handles rooftop heat (384.8 W PTC), 8 kW sizing, and cold winter string voltage.

SOLAREVER TECNOLOG A DE AMERICA SA DE CV builds the SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108 (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 209.6 W/m2 (1.05 percentage points above 19.91% CEC median). Compared against AXITEC AC-415MH/108V (415.0 W), this model holds strong 92.7% PTC-to-STC heat retention (#11,468 of 21,677). Lower 37.25 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 21.42 A overcurrent floor served by a 25 A breaker.

Where Does SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108 Fall Across Listed CEC Models?

Where SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108 (415.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108 (415.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSOLAREVER TECNOLOG: 415.0 W

What Dataset Percentiles Define SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108?

Percentile placement of SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108 across power density (209.6 W/m2), thermal retention, and nameplate STC wattage.

SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108 Engineering BenchmarksPercentile comparison of SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage415.0 WPTC/STC Retention92.7%Module Efficiency20.96%

What Do the Dataset Ranks Show for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108?

Four critical engineering numbers homeowners and solar installers check first when reviewing SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108 specifications.

Rank #8,199 / 21,677

Top 39.4% STC Output

415.0 W STC (+30.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #6,565

20.96% Aperture Efficiency

Power density 209.6 W/m2 (1.05 percentage points above 19.91% CEC median). PTC/STC ratio: 92.7% (rank #11,468).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 41.08 V at -10 C (575.1 V string) and 42.18 V at -20 C (14 max).

8 kW Reference Array

20 Panels = 8,300 W STC

Occupies 39.6 m2 (426 sq ft) producing 7,696 W PTC; NEC 690.8 OCPD floor is 21.42 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.25 * (1 + (-0.294/100) * (-10 - 25)) = 41.08 V | OCPD = 1.56 * 13.73 = 21.42 A

Inputs from CEC Modules.csv for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108: Voc=37.25 V, beta_Voc=-0.294%/C, Isc=13.73 A, STC=415.0 W, Area=1.98 m2.

Result: 14 panels max on 600 V (575.1 V); 20 panels for 8 kW (426 sq ft).

What Are the Published CEC Specifications for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108.

Official California Energy Commission (NREL SAM) test parameters for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 415.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 384.8 W (92.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.25 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.73 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.42 V / 13.21 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.294 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.96% (1.98 m2) Array roof footprint density
Cell Count & Technology 36 cells (Mono-c-Si) Monofacial backsheet

How Many SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108 (415.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.22 kW 320 sq ft $1,557 $2,632
8 kW Class 20 8.3 kW 426 sq ft $2,077 $3,513
10 kW Class 25 10.38 kW 533 sq ft $2,598 $4,393

Which Sibling Wattage & Trim Variants Belong to This SOLAREVER TECNOLOG A DE AMERICA SA DE CV Series?

All closely matched SOLAREVER TECNOLOG A DE AMERICA SA DE CV wattages and cosmetic trims sharing the SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108 architecture.

Sibling CEC listings grouped into the SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-410M-108 410.0 W 380.0 W 37.05 V 31.2 V 20.71%
SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108 415.0 W 384.8 W 37.25 V 31.42 V 20.96%
SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-420M-108 420.0 W 389.5 W 37.45 V 31.63 V 21.21%

How Many SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108 Modules Fit in a Cold-Weather String?

Maximum series module counts for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=37.25V and beta_Voc=-0.294%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 42.18 V 14 panels 590.5 V 23 panels
-10 C (14 F) 41.08 V 14 panels 575.1 V 24 panels
0 C (32 F) 39.99 V 15 panels 599.9 V 25 panels
25 C (77 F STC) 37.25 V 16 panels 596.0 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108?

Alternative CEC solar modules from competing brands near SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108 (415.0 W), including AXITEC AC-415MH/108V.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
AXITEC AC-415MH/108V
AXITEC
415.0 W Tie (0 W) 37.38 V 21.5% 92.7%
Aptos Solar Technology LLC DNA-108-BF10-415W
Aptos Solar Technology LLC
415.0 W Tie (0 W) 37.5 V 21.28% 94.3%
Aptos Solar Technology LLC DNA-108-MF10-415W-USAptos1a
Aptos Solar Technology LLC
415.0 W Tie (0 W) 37.7 V 21.39% 93.0%
AXITEC AC-415TGB/108BB
AXITEC
415.0 W Tie (0 W) 38.04 V 21.84% 94.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108?

Evaluate SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108 (415.0 W STC, 37.25 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108 reaches 42.18 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 426 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (426 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108 8 kW Residential Fit

Needs 20 modules (426 sq ft) with a 25 A string OCPD, offsetting ~$2,077/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare AXITEC AC-415MH/108V.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 384.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108 by SOLAREVER TECNOLOG A DE AMERICA SA DE CV grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108?

Multiplying SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108's 13.73 A short-circuit current by 1.56 equals 21.42 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

Can SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 41.08 V cold Voc at 14 F and handles 13.73 A Isc; string inverters cap SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108 at 14 panels on 600 V.

Is SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108 rely on utility bill offset (~$2,077/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.