SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108 is a 415.0 W STC (384.8 W PTC) Mono-c-Si solar module ranking #8,199 of 21,677 CEC listings (top 39.4%; higher than 60.6% of peers). It delivers 20.96% efficiency, 37.25 V Voc at 25 C, and 41.08 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 415.0 W
- PTC Wattage
- 384.8 W
- Voc @ 25C
- 37.25 V
- Efficiency
- 20.96%
How Does SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108 Compare Against Peer CEC Listings?
How SOLAREVER TECNOLOG A DE AMERICA SA DE CV SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108 handles rooftop heat (384.8 W PTC), 8 kW sizing, and cold winter string voltage.
SOLAREVER TECNOLOG A DE AMERICA SA DE CV builds the SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108 (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 209.6 W/m2 (1.05 percentage points above 19.91% CEC median). Compared against AXITEC AC-415MH/108V (415.0 W), this model holds strong 92.7% PTC-to-STC heat retention (#11,468 of 21,677). Lower 37.25 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 21.42 A overcurrent floor served by a 25 A breaker.
Where Does SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108 Fall Across Listed CEC Models?
Where SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108 (415.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108?
Percentile placement of SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108 across power density (209.6 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108?
Four critical engineering numbers homeowners and solar installers check first when reviewing SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108 specifications.
Top 39.4% STC Output
415.0 W STC (+30.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.96% Aperture Efficiency
Power density 209.6 W/m2 (1.05 percentage points above 19.91% CEC median). PTC/STC ratio: 92.7% (rank #11,468).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 41.08 V at -10 C (575.1 V string) and 42.18 V at -20 C (14 max).
20 Panels = 8,300 W STC
Occupies 39.6 m2 (426 sq ft) producing 7,696 W PTC; NEC 690.8 OCPD floor is 21.42 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 37.25 * (1 + (-0.294/100) * (-10 - 25)) = 41.08 V | OCPD = 1.56 * 13.73 = 21.42 A
Inputs from CEC Modules.csv for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108: Voc=37.25 V, beta_Voc=-0.294%/C, Isc=13.73 A, STC=415.0 W, Area=1.98 m2.
Result: 14 panels max on 600 V (575.1 V); 20 panels for 8 kW (426 sq ft).
What Are the Published CEC Specifications for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 415.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 384.8 W (92.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 37.25 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.73 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.42 V / 13.21 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.294 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.96% (1.98 m2) | Array roof footprint density |
| Cell Count & Technology | 36 cells (Mono-c-Si) | Monofacial backsheet |
How Many SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108 (415.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.22 kW | 320 sq ft | $1,557 | $2,632 |
| 8 kW Class | 20 | 8.3 kW | 426 sq ft | $2,077 | $3,513 |
| 10 kW Class | 25 | 10.38 kW | 533 sq ft | $2,598 | $4,393 |
Which Sibling Wattage & Trim Variants Belong to This SOLAREVER TECNOLOG A DE AMERICA SA DE CV Series?
All closely matched SOLAREVER TECNOLOG A DE AMERICA SA DE CV wattages and cosmetic trims sharing the SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108 architecture.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-410M-108 | 410.0 W | 380.0 W | 37.05 V | 31.2 V | 20.71% |
| SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108 | 415.0 W | 384.8 W | 37.25 V | 31.42 V | 20.96% |
| SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-420M-108 | 420.0 W | 389.5 W | 37.45 V | 31.63 V | 21.21% |
How Many SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108 Modules Fit in a Cold-Weather String?
Maximum series module counts for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 42.18 V | 14 panels | 590.5 V | 23 panels |
| -10 C (14 F) | 41.08 V | 14 panels | 575.1 V | 24 panels |
| 0 C (32 F) | 39.99 V | 15 panels | 599.9 V | 25 panels |
| 25 C (77 F STC) | 37.25 V | 16 panels | 596.0 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108?
Alternative CEC solar modules from competing brands near SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108 (415.0 W), including AXITEC AC-415MH/108V.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| AXITEC AC-415MH/108V AXITEC |
415.0 W | Tie (0 W) | 37.38 V | 21.5% | 92.7% |
| Aptos Solar Technology LLC DNA-108-BF10-415W Aptos Solar Technology LLC |
415.0 W | Tie (0 W) | 37.5 V | 21.28% | 94.3% |
| Aptos Solar Technology LLC DNA-108-MF10-415W-USAptos1a Aptos Solar Technology LLC |
415.0 W | Tie (0 W) | 37.7 V | 21.39% | 93.0% |
| AXITEC AC-415TGB/108BB AXITEC |
415.0 W | Tie (0 W) | 38.04 V | 21.84% | 94.9% |
What Are the Design Limits and Best-Fit Uses for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108?
Evaluate SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108 (415.0 W STC, 37.25 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108 reaches 42.18 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 426 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (426 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108 8 kW Residential Fit
Needs 20 modules (426 sq ft) with a 25 A string OCPD, offsetting ~$2,077/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare AXITEC AC-415MH/108V.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 384.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108 by SOLAREVER TECNOLOG A DE AMERICA SA DE CV grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108?
Multiplying SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108's 13.73 A short-circuit current by 1.56 equals 21.42 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 41.08 V cold Voc at 14 F and handles 13.73 A Isc; string inverters cap SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108 at 14 panels on 600 V.
Is SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108 rely on utility bill offset (~$2,077/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)