Skip to main content
WireAndSun
Calculators
CEC PV Module

SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 — CEC Solar Module Specifications

Manufacturer: SOLAREVER TECNOLOG A DE AMERICA SA DE CV Registry: CEC Verified Engineering Specification

SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 is a 545.0 W STC (506.4 W PTC) Mono-c-Si solar module ranking #2,998 of 21,677 CEC listings (top 15.1%; higher than 84.9% of peers). It delivers 21.29% efficiency, 49.78 V Voc at 25 C, and 54.75 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
545.0 W
PTC Wattage
506.4 W
Voc @ 25C
49.78 V
Efficiency
21.29%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 Compare Against Peer CEC Listings?

How SOLAREVER TECNOLOG A DE AMERICA SA DE CV SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 handles rooftop heat (506.4 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 exhibits 13.59 A short-circuit current, requiring a 21.2 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #2,998 of 21,677 (135.0 W above the 410.0 W Mono-c-Si median), this large-format commercial and ground-mount module covers 38.4 m2 for an 8 kW system (19 panels for 10 kW). Higher 49.78 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).

Where Does SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 Fall Across Listed CEC Models?

Where SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 (545.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 (545.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSOLAREVER TECNOLOG: 545.0 W

What Dataset Percentiles Define SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144?

Percentile placement of SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 across power density (212.9 W/m2), thermal retention, and nameplate STC wattage.

SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 Engineering BenchmarksPercentile comparison of SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage545.0 WPTC/STC Retention92.9%Module Efficiency21.29%

What Do the Dataset Ranks Show for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144?

Four critical engineering numbers homeowners and solar installers check first when reviewing SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 specifications.

Rank #2,998 / 21,677

Top 15.1% STC Output

545.0 W STC (+160.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #5,168

21.29% Aperture Efficiency

Power density 212.9 W/m2 (1.38 percentage points above 19.91% CEC median). PTC/STC ratio: 92.9% (rank #10,348).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.75 V at -10 C (547.5 V string) and 56.16 V at -20 C (10 max).

8 kW Reference Array

15 Panels = 8,175 W STC

Occupies 38.4 m2 (413 sq ft) producing 7,596 W PTC; NEC 690.8 OCPD floor is 21.2 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.78 * (1 + (-0.285/100) * (-10 - 25)) = 54.75 V | OCPD = 1.56 * 13.59 = 21.2 A

Inputs from CEC Modules.csv for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144: Voc=49.78 V, beta_Voc=-0.285%/C, Isc=13.59 A, STC=545.0 W, Area=2.56 m2.

Result: 10 panels max on 600 V (547.5 V); 15 panels for 8 kW (413 sq ft).

What Are the Published CEC Specifications for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144.

Official California Energy Commission (NREL SAM) test parameters for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 545.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 506.4 W (92.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 49.78 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.59 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 41.7 V / 13.07 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.285 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.29% (2.56 m2) Array roof footprint density
Cell Count & Technology 48 cells (Mono-c-Si) Monofacial backsheet

How Many SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 (545.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 12 6.54 kW 331 sq ft $1,637 $2,768
8 kW Class 15 8.18 kW 413 sq ft $2,047 $3,462
10 kW Class 19 10.36 kW 524 sq ft $2,593 $4,385

How Many SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 Modules Fit in a Cold-Weather String?

Maximum series module counts for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=49.78V and beta_Voc=-0.285%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 56.16 V 10 panels 561.6 V 17 panels
-10 C (14 F) 54.75 V 10 panels 547.5 V 18 panels
0 C (32 F) 53.33 V 11 panels 586.6 V 18 panels
25 C (77 F STC) 49.78 V 12 panels 597.4 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144?

Alternative CEC solar modules from competing brands near SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 (545.0 W), including Exiom Solution S A EX550-144MH.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Exiom Solution S A EX550-144MH
Exiom Solution S A
545.0 W Tie (0 W) 49.8 V 21.46% 92.5%
Alexus Solar ALEX-545-B-72-S
Alexus Solar
545.0 W Tie (0 W) 49.68 V 21.12% 92.6%
Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8-545
Jiangsu Runergy New Energy Technology Co Ltd
545.0 W Tie (0 W) 50.07 V 21.12% 93.8%
Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8b-545
Jiangsu Runergy New Energy Technology Co Ltd
545.0 W Tie (0 W) 50.07 V 21.12% 93.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144?

Evaluate SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 (545.0 W STC, 49.78 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 reaches 56.16 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 15 panels for an 8 kW build require 413 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 8 kW Residential Fit

Needs 15 modules (413 sq ft) with a 25 A string OCPD, offsetting ~$2,047/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Exiom Solution S A EX550-144MH.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 506.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 by SOLAREVER TECNOLOG A DE AMERICA SA DE CV grounded in CEC test data and NEC 690.7/690.8 limits.

Why is SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 PTC wattage (506.4 W) lower than STC (545.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 506.4 W PTC (92.9% retention) across SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144's 2.56 m2 aperture.

Who should skip SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 15 SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 panels (413 sq ft) leave unusable roof gaps vs. Exiom Solution S A EX550-144MH.

What is the 1,000 V commercial string limit for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144?

On 1,000 V commercial inverters at -10 C (54.75 V cold Voc), SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 fits up to 18 panels per series string.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.