SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 is a 545.0 W STC (506.4 W PTC) Mono-c-Si solar module ranking #2,998 of 21,677 CEC listings (top 15.1%; higher than 84.9% of peers). It delivers 21.29% efficiency, 49.78 V Voc at 25 C, and 54.75 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 545.0 W
- PTC Wattage
- 506.4 W
- Voc @ 25C
- 49.78 V
- Efficiency
- 21.29%
How Does SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 Compare Against Peer CEC Listings?
How SOLAREVER TECNOLOG A DE AMERICA SA DE CV SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 handles rooftop heat (506.4 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 exhibits 13.59 A short-circuit current, requiring a 21.2 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #2,998 of 21,677 (135.0 W above the 410.0 W Mono-c-Si median), this large-format commercial and ground-mount module covers 38.4 m2 for an 8 kW system (19 panels for 10 kW). Higher 49.78 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).
Where Does SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 Fall Across Listed CEC Models?
Where SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 (545.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144?
Percentile placement of SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 across power density (212.9 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144?
Four critical engineering numbers homeowners and solar installers check first when reviewing SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 specifications.
Top 15.1% STC Output
545.0 W STC (+160.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.29% Aperture Efficiency
Power density 212.9 W/m2 (1.38 percentage points above 19.91% CEC median). PTC/STC ratio: 92.9% (rank #10,348).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 54.75 V at -10 C (547.5 V string) and 56.16 V at -20 C (10 max).
15 Panels = 8,175 W STC
Occupies 38.4 m2 (413 sq ft) producing 7,596 W PTC; NEC 690.8 OCPD floor is 21.2 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.78 * (1 + (-0.285/100) * (-10 - 25)) = 54.75 V | OCPD = 1.56 * 13.59 = 21.2 A
Inputs from CEC Modules.csv for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144: Voc=49.78 V, beta_Voc=-0.285%/C, Isc=13.59 A, STC=545.0 W, Area=2.56 m2.
Result: 10 panels max on 600 V (547.5 V); 15 panels for 8 kW (413 sq ft).
What Are the Published CEC Specifications for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 545.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 506.4 W (92.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.78 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.59 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 41.7 V / 13.07 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.285 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.29% (2.56 m2) | Array roof footprint density |
| Cell Count & Technology | 48 cells (Mono-c-Si) | Monofacial backsheet |
How Many SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 (545.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 12 | 6.54 kW | 331 sq ft | $1,637 | $2,768 |
| 8 kW Class | 15 | 8.18 kW | 413 sq ft | $2,047 | $3,462 |
| 10 kW Class | 19 | 10.36 kW | 524 sq ft | $2,593 | $4,385 |
How Many SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 Modules Fit in a Cold-Weather String?
Maximum series module counts for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 56.16 V | 10 panels | 561.6 V | 17 panels |
| -10 C (14 F) | 54.75 V | 10 panels | 547.5 V | 18 panels |
| 0 C (32 F) | 53.33 V | 11 panels | 586.6 V | 18 panels |
| 25 C (77 F STC) | 49.78 V | 12 panels | 597.4 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144?
Alternative CEC solar modules from competing brands near SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 (545.0 W), including Exiom Solution S A EX550-144MH.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Exiom Solution S A EX550-144MH Exiom Solution S A |
545.0 W | Tie (0 W) | 49.8 V | 21.46% | 92.5% |
| Alexus Solar ALEX-545-B-72-S Alexus Solar |
545.0 W | Tie (0 W) | 49.68 V | 21.12% | 92.6% |
| Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8-545 Jiangsu Runergy New Energy Technology Co Ltd |
545.0 W | Tie (0 W) | 50.07 V | 21.12% | 93.8% |
| Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8b-545 Jiangsu Runergy New Energy Technology Co Ltd |
545.0 W | Tie (0 W) | 50.07 V | 21.12% | 93.8% |
What Are the Design Limits and Best-Fit Uses for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144?
Evaluate SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 (545.0 W STC, 49.78 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 reaches 56.16 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 413 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 8 kW Residential Fit
Needs 15 modules (413 sq ft) with a 25 A string OCPD, offsetting ~$2,047/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Exiom Solution S A EX550-144MH.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 506.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 by SOLAREVER TECNOLOG A DE AMERICA SA DE CV grounded in CEC test data and NEC 690.7/690.8 limits.
Why is SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 PTC wattage (506.4 W) lower than STC (545.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 506.4 W PTC (92.9% retention) across SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144's 2.56 m2 aperture.
Who should skip SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 15 SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 panels (413 sq ft) leave unusable roof gaps vs. Exiom Solution S A EX550-144MH.
What is the 1,000 V commercial string limit for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144?
On 1,000 V commercial inverters at -10 C (54.75 V cold Voc), SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 fits up to 18 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)