Skip to main content
WireAndSun
Calculators
CEC PV Module

SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-445M-96-BD — CEC Solar Module Specifications

Manufacturer: SOLAREVER TECNOLOG A DE AMERICA SA DE CV Registry: CEC Verified Engineering Specification

SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-445M-96-BD is a 445.0 W STC (418.8 W PTC) Mono-c-Si solar module ranking #6,028 of 21,677 CEC listings (top 29.6%; higher than 70.4% of peers). It delivers 22.47% efficiency, 34.85 V Voc at 25 C, and 37.9 V cold Voc at -10 C (15 panels max per 600 V string).

STC Wattage
445.0 W
PTC Wattage
418.8 W
Voc @ 25C
34.85 V
Efficiency
22.47%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-445M-96-BD Compare Against Peer CEC Listings?

How SOLAREVER TECNOLOG A DE AMERICA SA DE CV SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-445M-96-BD handles rooftop heat (418.8 W PTC), 8 kW sizing, and cold winter string voltage.

SOLAREVER TECNOLOG A DE AMERICA SA DE CV builds the SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-445M-96-BD (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 224.7 W/m2 (2.56 percentage points above 19.91% CEC median). Compared against ELITE Solar ET-NR48TBH440GB (440.0 W), this model holds strong 94.1% PTC-to-STC heat retention (#4,203 of 21,677). Lower 34.85 V string voltage fits 15 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 24.96 A overcurrent floor served by a 25 A breaker.

Where Does SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-445M-96-BD Fall Across Listed CEC Models?

Where SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-445M-96-BD (445.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-445M-96-BD (445.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSOLAREVER TECNOLOG: 445.0 W

What Dataset Percentiles Define SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-445M-96-BD?

Percentile placement of SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-445M-96-BD across power density (224.7 W/m2), thermal retention, and nameplate STC wattage.

SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-445M-96-BD Engineering BenchmarksPercentile comparison of SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-445M-96-BD wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage445.0 WPTC/STC Retention94.1%Module Efficiency22.47%

What Do the Dataset Ranks Show for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-445M-96-BD?

Four critical engineering numbers homeowners and solar installers check first when reviewing SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-445M-96-BD specifications.

Rank #6,028 / 21,677

Top 29.6% STC Output

445.0 W STC (+60.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #2,111

22.47% Aperture Efficiency

Power density 224.7 W/m2 (2.56 percentage points above 19.91% CEC median). PTC/STC ratio: 94.1% (rank #4,203).

NEC 690.7 Limit

15 Panels Max @ -10 C (600 V)

Cold Voc reaches 37.9 V at -10 C (568.5 V string) and 38.77 V at -20 C (15 max).

8 kW Reference Array

18 Panels = 8,010 W STC

Occupies 35.6 m2 (384 sq ft) producing 7,538 W PTC; NEC 690.8 OCPD floor is 24.96 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 34.85 * (1 + (-0.25/100) * (-10 - 25)) = 37.9 V | OCPD = 1.56 * 16.0 = 24.96 A

Inputs from CEC Modules.csv for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-445M-96-BD: Voc=34.85 V, beta_Voc=-0.25%/C, Isc=16.0 A, STC=445.0 W, Area=1.98 m2.

Result: 15 panels max on 600 V (568.5 V); 18 panels for 8 kW (384 sq ft).

What Are the Published CEC Specifications for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-445M-96-BD?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-445M-96-BD.

Official California Energy Commission (NREL SAM) test parameters for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-445M-96-BD.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 445.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 418.8 W (94.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 34.85 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 16.0 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 29.9 V / 14.89 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.25 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 22.47% (1.98 m2) Array roof footprint density
Cell Count & Technology 32 cells (Mono-c-Si) Monofacial backsheet

How Many SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-445M-96-BD Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-445M-96-BD (445.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.23 kW 298 sq ft $1,559 $2,637
8 kW Class 18 8.01 kW 384 sq ft $2,005 $3,390
10 kW Class 23 10.23 kW 490 sq ft $2,560 $4,330

Which Sibling Wattage & Trim Variants Belong to This SOLAREVER TECNOLOG A DE AMERICA SA DE CV Series?

All closely matched SOLAREVER TECNOLOG A DE AMERICA SA DE CV wattages and cosmetic trims sharing the SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-445M-96-BD architecture.

Sibling CEC listings grouped into the SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-445M-96-BD wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-440M-96-BD 440.0 W 413.9 W 34.67 V 29.72 V 22.22%
SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-445M-96-BD 445.0 W 418.8 W 34.85 V 29.9 V 22.47%

How Many SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-445M-96-BD Modules Fit in a Cold-Weather String?

Maximum series module counts for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-445M-96-BD from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=34.85V and beta_Voc=-0.25%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 38.77 V 15 panels 581.6 V 25 panels
-10 C (14 F) 37.9 V 15 panels 568.5 V 26 panels
0 C (32 F) 37.03 V 16 panels 592.5 V 27 panels
25 C (77 F STC) 34.85 V 17 panels 592.5 V 28 panels

Which Cross-Brand Solar Modules Compare Closest to SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-445M-96-BD?

Alternative CEC solar modules from competing brands near SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-445M-96-BD (445.0 W), including ELITE Solar ET-NR48TBH440GB.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
ELITE Solar ET-NR48TBH440GB
ELITE Solar
440.0 W -5.0 W 35.29 V 22.0% 95.0%
ELITE Solar ET-NR48TBH440GL
ELITE Solar
440.0 W -5.0 W 35.29 V 22.0% 95.0%
CSI Solar Co Ltd CS62-48TM-440H
CSI Solar Co Ltd
440.0 W -5.0 W 35.4 V 22.8% 94.9%
CSI Solar Co Ltd CS61-54TM-440H
CSI Solar Co Ltd
440.0 W -5.0 W 38.5 V 22.22% 94.7%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-445M-96-BD?

Evaluate SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-445M-96-BD (445.0 W STC, 34.85 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-445M-96-BD reaches 38.77 V per panel—exceeding 15 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 18 panels for an 8 kW build require 384 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (384 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-445M-96-BD carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-445M-96-BD 8 kW Residential Fit

Needs 18 modules (384 sq ft) with a 25 A string OCPD, offsetting ~$2,005/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 15 panels (-10 C) or 15 panels (-20 C), or compare ELITE Solar ET-NR48TBH440GB.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 418.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-445M-96-BD by SOLAREVER TECNOLOG A DE AMERICA SA DE CV grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-445M-96-BD?

Multiplying SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-445M-96-BD's 16.0 A short-circuit current by 1.56 equals 24.96 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

Can SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-445M-96-BD pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 37.9 V cold Voc at 14 F and handles 16.0 A Isc; string inverters cap SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-445M-96-BD at 15 panels on 600 V.

Is SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-445M-96-BD eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-445M-96-BD rely on utility bill offset (~$2,005/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.