Solar Frontier KK SF175-S is a 175.0 W STC (159.2 W PTC) Thin Film solar module ranking #21,282 of 21,677 CEC listings (below all-CEC median; higher than 1.6% of peers). It delivers 16.72% efficiency, 114.0 V Voc at 25 C, and 125.17 V cold Voc at -10 C (4 panels max per 600 V string).
- STC Wattage
- 175.0 W
- PTC Wattage
- 159.2 W
- Voc @ 25C
- 114.0 V
- Efficiency
- 16.72%
How Does Solar Frontier KK SF175-S Compare Against Peer CEC Listings?
How Solar Frontier KK Solar Frontier KK SF175-S handles rooftop heat (159.2 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, Solar Frontier KK SF175-S exhibits 2.2 A short-circuit current, requiring a 3.43 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #21,282 of 21,677 (57.5 W above the 117.5 W Thin Film median), this compact residential or specialty off-grid module covers 48.2 m2 for an 8 kW system (58 panels for 10 kW). Higher 114.0 V open-circuit voltage caps 600 V residential strings at 4 panels at 14 F (-10 C).
Where Does Solar Frontier KK SF175-S Fall Across Listed CEC Models?
Where Solar Frontier KK SF175-S (175.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Solar Frontier KK SF175-S?
Percentile placement of Solar Frontier KK SF175-S across power density (167.1 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Solar Frontier KK SF175-S?
Four critical engineering numbers homeowners and solar installers check first when reviewing Solar Frontier KK SF175-S specifications. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
175.0 W STC · Higher Than 1.6%
175.0 W STC (-210.0 W vs all-CEC median) vs 117.5 W Thin Film median.
16.72% Aperture Efficiency
Power density 167.1 W/m2 (3.19 percentage points below 19.91% CEC median). PTC/STC ratio: 91.0% (rank #16,685).
4 Panels Max @ -10 C (600 V)
Cold Voc reaches 125.17 V at -10 C (500.7 V string) and 128.36 V at -20 C (4 max).
46 Panels = 8,050 W STC
Occupies 48.2 m2 (518 sq ft) producing 7,323 W PTC; NEC 690.8 OCPD floor is 3.43 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 114.0 * (1 + (-0.28/100) * (-10 - 25)) = 125.17 V | OCPD = 1.56 * 2.2 = 3.43 A
Inputs from CEC Modules.csv for Solar Frontier KK SF175-S: Voc=114.0 V, beta_Voc=-0.28%/C, Isc=2.2 A, STC=175.0 W, Area=1.047 m2.
Result: 4 panels max on 600 V (500.7 V); 46 panels for 8 kW (518 sq ft).
What Are the Published CEC Specifications for Solar Frontier KK SF175-S?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Solar Frontier KK SF175-S.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 175.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 159.2 W (91.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 114.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 2.2 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 89.5 V / 1.96 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.28 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 16.72% (1.047 m2) | Array roof footprint density |
| Cell Count & Technology | 170 cells (Thin Film) | Monofacial backsheet |
How Many Solar Frontier KK SF175-S Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Solar Frontier KK SF175-S (175.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 35 | 6.12 kW | 394 sq ft | $1,532 | $2,590 |
| 8 kW Class | 46 | 8.05 kW | 518 sq ft | $2,015 | $3,407 |
| 10 kW Class | 58 | 10.15 kW | 654 sq ft | $2,540 | $4,296 |
How Many Solar Frontier KK SF175-S Modules Fit in a Cold-Weather String?
Maximum series module counts for Solar Frontier KK SF175-S from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 128.36 V | 4 panels | 513.4 V | 7 panels |
| -10 C (14 F) | 125.17 V | 4 panels | 500.7 V | 7 panels |
| 0 C (32 F) | 121.98 V | 4 panels | 487.9 V | 8 panels |
| 25 C (77 F STC) | 114.0 V | 5 panels | 570.0 V | 8 panels |
Which Cross-Brand Solar Modules Compare Closest to Solar Frontier KK SF175-S?
Alternative CEC solar modules from competing brands near Solar Frontier KK SF175-S (175.0 W), including Du Pont Apollo DA105-A2.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Du Pont Apollo DA105-A2 Du Pont Apollo |
105.0 W | -70.0 W | 100.0 V | 6.82% | 91.0% |
| Du Pont Apollo DA102-A6 Du Pont Apollo |
102.0 W | -73.0 W | 100.0 V | 6.62% | 94.2% |
| Applied Materials 1/4 Size Single Junction Version 10 Applied Materials |
116.0 W | -59.0 W | 96.2 V | 8.11% | 93.0% |
| Centrosolar America VS-155C2 Centrosolar America |
155.0 W | -20.0 W | 82.85 V | 14.27% | 93.0% |
What Are the Design Limits and Best-Fit Uses for Solar Frontier KK SF175-S?
Evaluate Solar Frontier KK SF175-S (175.0 W STC, 114.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Solar Frontier KK SF175-S reaches 128.36 V per panel—exceeding 4 panels in series voids 600 V inverter warranties.
- Footprint constraint: 46 panels for an 8 kW build require 518 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 46 panels (518 sq ft).
- 2026 tax credit baseline: cash residential installs of Solar Frontier KK SF175-S carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Solar Frontier KK SF175-S 8 kW Residential Fit
Needs 46 modules (518 sq ft) with a 15 A string OCPD, offsetting ~$2,015/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 4 panels (-10 C) or 4 panels (-20 C), or compare Du Pont Apollo DA105-A2.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 159.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Solar Frontier KK SF175-S by Solar Frontier KK grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Solar Frontier KK SF175-S PTC wattage (159.2 W) lower than STC (175.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 159.2 W PTC (91.0% retention) across Solar Frontier KK SF175-S's 1.047 m2 aperture.
Who should skip Solar Frontier KK SF175-S on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 46 Solar Frontier KK SF175-S panels (518 sq ft) leave unusable roof gaps vs. Du Pont Apollo DA105-A2.
What is the 1,000 V commercial string limit for Solar Frontier KK SF175-S?
On 1,000 V commercial inverters at -10 C (125.17 V cold Voc), Solar Frontier KK SF175-S fits up to 7 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Solar Frontier KK SF175-S.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)