Solar Frontier KK SF160-S — CEC Solar Module Specifications

Manufacturer: Solar Frontier KK Registry: CEC Verified Engineering Specification

Solar Frontier KK SF160-S is a 160.0 W STC (144.6 W PTC) Thin Film solar module ranking #21,373 of 21,677 CEC listings (below all-CEC median; higher than 1.3% of peers). It delivers 15.28% efficiency, 110.0 V Voc at 25 C, and 121.55 V cold Voc at -10 C (4 panels max per 600 V string).

STC Wattage
160.0 W
PTC Wattage
144.6 W
Voc @ 25C
110.0 V
Efficiency
15.28%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Solar Frontier KK SF160-S Compare Against Peer CEC Listings?

Solar engineering breakdown for Solar Frontier KK SF160-S: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 106 Thin Film listings from Solar Frontier KK and peers, Solar Frontier KK SF160-S stands 42.5 W above the 117.5 W Thin Film median and typical 90.4% PTC-to-STC thermal output (144.6 W real-world rating). Sizing 6 kW (38 panels) to 10 kW (63 panels) yields $1,522-$2,523/yr in baseline US bill offset. Higher 110.0 V open-circuit voltage caps 600 V residential strings at 4 panels at 14 F (-10 C).

Where Does Solar Frontier KK SF160-S Fall Across Listed CEC Models?

Distribution marker showing Solar Frontier KK SF160-S (160.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Solar Frontier KK SF160-S (160.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSolar Frontier KK : 160.0 W

What Dataset Percentiles Define Solar Frontier KK SF160-S?

Dataset percentiles tracking Solar Frontier KK SF160-S power output, thermal retention ratio, and aperture efficiency against 21,677 models.

Solar Frontier KK SF160-S Engineering BenchmarksPercentile comparison of Solar Frontier KK SF160-S wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage160.0 WPTC/STC Retention90.4%Module Efficiency15.28%

What Do the Dataset Ranks Show for Solar Frontier KK SF160-S?

Benchmark highlights for Solar Frontier KK SF160-S covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #21,373 / 21,677

160.0 W STC · Higher Than 1.3%

160.0 W STC (-225.0 W vs all-CEC median) vs 117.5 W Thin Film median.

Eff #19,278

15.28% Aperture Efficiency

Power density 152.8 W/m2 (4.63 percentage points below 19.91% CEC median). PTC/STC ratio: 90.4% (rank #18,018).

NEC 690.7 Limit

4 Panels Max @ -10 C (600 V)

Cold Voc reaches 121.55 V at -10 C (486.2 V string) and 124.85 V at -20 C (4 max).

8 kW Reference Array

50 Panels = 8,000 W STC

Occupies 52.3 m2 (563 sq ft) producing 7,230 W PTC; NEC 690.8 OCPD floor is 3.43 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 110.0 * (1 + (-0.3/100) * (-10 - 25)) = 121.55 V | OCPD = 1.56 * 2.2 = 3.43 A

Inputs from CEC Modules.csv for Solar Frontier KK SF160-S: Voc=110.0 V, beta_Voc=-0.3%/C, Isc=2.2 A, STC=160.0 W, Area=1.047 m2.

Result: 4 panels max on 600 V (486.2 V); 50 panels for 8 kW (563 sq ft).

What Are the Published CEC Specifications for Solar Frontier KK SF160-S?

Official CEC datasheet figures for Solar Frontier KK SF160-S (Thin Film) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for Solar Frontier KK SF160-S.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 160.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 144.6 W (90.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 110.0 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 2.2 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 84.0 V / 1.91 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.3 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 15.28% (1.047 m2) Array roof footprint density
Cell Count & Technology 170 cells (Thin Film) Monofacial backsheet

How Many Solar Frontier KK SF160-S Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Solar Frontier KK SF160-S modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 38 6.08 kW 428 sq ft $1,522 $2,573
8 kW Class 50 8.0 kW 563 sq ft $2,002 $3,386
10 kW Class 63 10.08 kW 710 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This Solar Frontier KK Series?

Consolidated Solar Frontier KK wattage variants sharing the Solar Frontier KK SF160-S mechanical and cell layout. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Sibling CEC listings grouped into the Solar Frontier KK SF160-S wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Solar Frontier KK SF150-S 150.0 W 135.8 W 108.0 V 81.5 V 14.33%
Solar Frontier KK SF155-S 155.0 W 140.5 W 109.0 V 82.5 V 14.81%
Solar Frontier KK SF160-S 160.0 W 144.6 W 110.0 V 84.0 V 15.28%
Solar Frontier KK SF165-S 165.0 W 149.2 W 110.0 V 85.5 V 15.76%
Solar Frontier KK SF170-S 170.0 W 153.8 W 112.0 V 87.5 V 16.24%

How Many Solar Frontier KK SF160-S Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Solar Frontier KK SF160-S (121.55 V at 14 F).

Computed from Voc=110.0V and beta_Voc=-0.3%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 124.85 V 4 panels 499.4 V 8 panels
-10 C (14 F) 121.55 V 4 panels 486.2 V 8 panels
0 C (32 F) 118.25 V 5 panels 591.2 V 8 panels
25 C (77 F STC) 110.0 V 5 panels 550.0 V 9 panels

Which Cross-Brand Solar Modules Compare Closest to Solar Frontier KK SF160-S?

Competing CEC solar panels closest to Solar Frontier KK SF160-S in nameplate wattage and Voc, starting with Du Pont Apollo DA105-A2.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Du Pont Apollo DA105-A2
Du Pont Apollo
105.0 W -55.0 W 100.0 V 6.82% 91.0%
Du Pont Apollo DA102-A6
Du Pont Apollo
102.0 W -58.0 W 100.0 V 6.62% 94.2%
Applied Materials 1/4 Size Single Junction Version 10
Applied Materials
116.0 W -44.0 W 96.2 V 8.11% 93.0%
Centrosolar America VS-155C2
Centrosolar America
155.0 W -5.0 W 82.85 V 14.27% 93.0%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Solar Frontier KK SF160-S?

Evaluate Solar Frontier KK SF160-S (160.0 W STC, 110.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Solar Frontier KK SF160-S reaches 124.85 V per panel—exceeding 4 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 50 panels for an 8 kW build require 563 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 50 panels (563 sq ft).
  • 2026 tax credit baseline: cash residential installs of Solar Frontier KK SF160-S carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Solar Frontier KK SF160-S 8 kW Residential Fit

Needs 50 modules (563 sq ft) with a 15 A string OCPD, offsetting ~$2,002/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 4 panels (-10 C) or 4 panels (-20 C), or compare Du Pont Apollo DA105-A2.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 144.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Solar Frontier KK SF160-S by Solar Frontier KK grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Solar Frontier KK SF160-S?

Multiplying Solar Frontier KK SF160-S's 2.2 A short-circuit current by 1.56 equals 3.43 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Solar Frontier KK SF160-S pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 121.55 V cold Voc at 14 F and handles 2.2 A Isc; string inverters cap Solar Frontier KK SF160-S at 4 panels on 600 V.

Is Solar Frontier KK SF160-S eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Solar Frontier KK SF160-S rely on utility bill offset (~$2,002/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.