Manufacturer: Solar Frontier KK Registry: CEC Verified Engineering Specification

Solar Frontier KK SF140-S is a 140.0 W STC (127.1 W PTC) Thin Film solar module ranking #21,440 of 21,677 CEC listings (below all-CEC median; higher than 1.0% of peers). It delivers 13.37% efficiency, 107.0 V Voc at 25 C, and 117.49 V cold Voc at -10 C (5 panels max per 600 V string).

STC Wattage
140.0 W
PTC Wattage
127.1 W
Voc @ 25C
107.0 V
Efficiency
13.37%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Solar Frontier KK SF140-S Compare Against Peer CEC Listings?

How Solar Frontier KK Solar Frontier KK SF140-S handles rooftop heat (127.1 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Solar Frontier KK SF140-S exhibits 2.1 A short-circuit current, requiring a 3.28 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #21,440 of 21,677 (22.5 W above the 117.5 W Thin Film median), this compact residential or specialty off-grid module covers 60.7 m2 for an 8 kW system (72 panels for 10 kW). Higher 107.0 V open-circuit voltage caps 600 V residential strings at 5 panels at 14 F (-10 C).

Where Does Solar Frontier KK SF140-S Fall Across Listed CEC Models?

Where Solar Frontier KK SF140-S (140.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Solar Frontier KK SF140-S (140.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSolar Frontier KK : 140.0 W

What Dataset Percentiles Define Solar Frontier KK SF140-S?

Percentile placement of Solar Frontier KK SF140-S across power density (133.7 W/m2), thermal retention, and nameplate STC wattage.

Solar Frontier KK SF140-S Engineering BenchmarksPercentile comparison of Solar Frontier KK SF140-S wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage140.0 WPTC/STC Retention90.8%Module Efficiency13.37%

What Do the Dataset Ranks Show for Solar Frontier KK SF140-S?

Four critical engineering numbers homeowners and solar installers check first when reviewing Solar Frontier KK SF140-S specifications. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Rank #21,440 / 21,677

140.0 W STC · Higher Than 1.0%

140.0 W STC (-245.0 W vs all-CEC median) vs 117.5 W Thin Film median.

Eff #21,274

13.37% Aperture Efficiency

Power density 133.7 W/m2 (6.54 percentage points below 19.91% CEC median). PTC/STC ratio: 90.8% (rank #17,104).

NEC 690.7 Limit

5 Panels Max @ -10 C (600 V)

Cold Voc reaches 117.49 V at -10 C (587.4 V string) and 120.48 V at -20 C (4 max).

8 kW Reference Array

58 Panels = 8,120 W STC

Occupies 60.7 m2 (654 sq ft) producing 7,372 W PTC; NEC 690.8 OCPD floor is 3.28 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 107.0 * (1 + (-0.28/100) * (-10 - 25)) = 117.49 V | OCPD = 1.56 * 2.1 = 3.28 A

Inputs from CEC Modules.csv for Solar Frontier KK SF140-S: Voc=107.0 V, beta_Voc=-0.28%/C, Isc=2.1 A, STC=140.0 W, Area=1.047 m2.

Result: 5 panels max on 600 V (587.4 V); 58 panels for 8 kW (654 sq ft).

What Are the Published CEC Specifications for Solar Frontier KK SF140-S?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Solar Frontier KK SF140-S.

Official California Energy Commission (NREL SAM) test parameters for Solar Frontier KK SF140-S.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 140.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 127.1 W (90.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 107.0 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 2.1 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 80.5 V / 1.74 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.28 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 13.37% (1.047 m2) Array roof footprint density
Cell Count & Technology 170 cells (Thin Film) Monofacial backsheet

How Many Solar Frontier KK SF140-S Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Solar Frontier KK SF140-S (140.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 43 6.02 kW 485 sq ft $1,507 $2,548
8 kW Class 58 8.12 kW 654 sq ft $2,032 $3,437
10 kW Class 72 10.08 kW 811 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This Solar Frontier KK Series?

All closely matched Solar Frontier KK wattages and cosmetic trims sharing the Solar Frontier KK SF140-S architecture. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Sibling CEC listings grouped into the Solar Frontier KK SF140-S wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Solar Frontier KK SF130-S 130.0 W 117.9 W 106.0 V 79.5 V 12.42%
Solar Frontier KK SF135-S 135.0 W 122.5 W 106.0 V 80.0 V 12.9%
Solar Frontier KK SF140-S 140.0 W 127.1 W 107.0 V 80.5 V 13.37%
Solar Frontier KK SF145-S 145.0 W 131.2 W 107.0 V 81.0 V 13.85%

How Many Solar Frontier KK SF140-S Modules Fit in a Cold-Weather String?

Maximum series module counts for Solar Frontier KK SF140-S from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=107.0V and beta_Voc=-0.28%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 120.48 V 4 panels 481.9 V 8 panels
-10 C (14 F) 117.49 V 5 panels 587.4 V 8 panels
0 C (32 F) 114.49 V 5 panels 572.4 V 8 panels
25 C (77 F STC) 107.0 V 5 panels 535.0 V 9 panels

Which Cross-Brand Solar Modules Compare Closest to Solar Frontier KK SF140-S?

Alternative CEC solar modules from competing brands near Solar Frontier KK SF140-S (140.0 W), including Du Pont Apollo DA105-A2.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Du Pont Apollo DA105-A2
Du Pont Apollo
105.0 W -35.0 W 100.0 V 6.82% 91.0%
Du Pont Apollo DA102-A6
Du Pont Apollo
102.0 W -38.0 W 100.0 V 6.62% 94.2%
Applied Materials 1/4 Size Single Junction Version 10
Applied Materials
116.0 W -24.0 W 96.2 V 8.11% 93.0%
Du Pont Apollo DA095-A2
Du Pont Apollo
95.0 W -45.0 W 100.0 V 6.17% 90.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Solar Frontier KK SF140-S?

Evaluate Solar Frontier KK SF140-S (140.0 W STC, 107.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Solar Frontier KK SF140-S reaches 120.48 V per panel—exceeding 4 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 58 panels for an 8 kW build require 654 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 58 panels (654 sq ft).
  • 2026 tax credit baseline: cash residential installs of Solar Frontier KK SF140-S carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Solar Frontier KK SF140-S 8 kW Residential Fit

Needs 58 modules (654 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 5 panels (-10 C) or 4 panels (-20 C), or compare Du Pont Apollo DA105-A2.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 127.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Solar Frontier KK SF140-S by Solar Frontier KK grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Solar Frontier KK SF140-S PTC wattage (127.1 W) lower than STC (140.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 127.1 W PTC (90.8% retention) across Solar Frontier KK SF140-S's 1.047 m2 aperture.

Who should skip Solar Frontier KK SF140-S on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 58 Solar Frontier KK SF140-S panels (654 sq ft) leave unusable roof gaps vs. Du Pont Apollo DA105-A2.

What is the 1,000 V commercial string limit for Solar Frontier KK SF140-S?

On 1,000 V commercial inverters at -10 C (117.49 V cold Voc), Solar Frontier KK SF140-S fits up to 8 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Solar Frontier KK SF140-S.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.