Solar Frontier KK SF140-S is a 140.0 W STC (127.1 W PTC) Thin Film solar module ranking #21,440 of 21,677 CEC listings (below all-CEC median; higher than 1.0% of peers). It delivers 13.37% efficiency, 107.0 V Voc at 25 C, and 117.49 V cold Voc at -10 C (5 panels max per 600 V string).
- STC Wattage
- 140.0 W
- PTC Wattage
- 127.1 W
- Voc @ 25C
- 107.0 V
- Efficiency
- 13.37%
How Does Solar Frontier KK SF140-S Compare Against Peer CEC Listings?
How Solar Frontier KK Solar Frontier KK SF140-S handles rooftop heat (127.1 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, Solar Frontier KK SF140-S exhibits 2.1 A short-circuit current, requiring a 3.28 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #21,440 of 21,677 (22.5 W above the 117.5 W Thin Film median), this compact residential or specialty off-grid module covers 60.7 m2 for an 8 kW system (72 panels for 10 kW). Higher 107.0 V open-circuit voltage caps 600 V residential strings at 5 panels at 14 F (-10 C).
Where Does Solar Frontier KK SF140-S Fall Across Listed CEC Models?
Where Solar Frontier KK SF140-S (140.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Solar Frontier KK SF140-S?
Percentile placement of Solar Frontier KK SF140-S across power density (133.7 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Solar Frontier KK SF140-S?
Four critical engineering numbers homeowners and solar installers check first when reviewing Solar Frontier KK SF140-S specifications. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
140.0 W STC · Higher Than 1.0%
140.0 W STC (-245.0 W vs all-CEC median) vs 117.5 W Thin Film median.
13.37% Aperture Efficiency
Power density 133.7 W/m2 (6.54 percentage points below 19.91% CEC median). PTC/STC ratio: 90.8% (rank #17,104).
5 Panels Max @ -10 C (600 V)
Cold Voc reaches 117.49 V at -10 C (587.4 V string) and 120.48 V at -20 C (4 max).
58 Panels = 8,120 W STC
Occupies 60.7 m2 (654 sq ft) producing 7,372 W PTC; NEC 690.8 OCPD floor is 3.28 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 107.0 * (1 + (-0.28/100) * (-10 - 25)) = 117.49 V | OCPD = 1.56 * 2.1 = 3.28 A
Inputs from CEC Modules.csv for Solar Frontier KK SF140-S: Voc=107.0 V, beta_Voc=-0.28%/C, Isc=2.1 A, STC=140.0 W, Area=1.047 m2.
Result: 5 panels max on 600 V (587.4 V); 58 panels for 8 kW (654 sq ft).
What Are the Published CEC Specifications for Solar Frontier KK SF140-S?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Solar Frontier KK SF140-S.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 140.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 127.1 W (90.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 107.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 2.1 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 80.5 V / 1.74 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.28 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 13.37% (1.047 m2) | Array roof footprint density |
| Cell Count & Technology | 170 cells (Thin Film) | Monofacial backsheet |
How Many Solar Frontier KK SF140-S Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Solar Frontier KK SF140-S (140.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 43 | 6.02 kW | 485 sq ft | $1,507 | $2,548 |
| 8 kW Class | 58 | 8.12 kW | 654 sq ft | $2,032 | $3,437 |
| 10 kW Class | 72 | 10.08 kW | 811 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This Solar Frontier KK Series?
All closely matched Solar Frontier KK wattages and cosmetic trims sharing the Solar Frontier KK SF140-S architecture. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Solar Frontier KK SF130-S | 130.0 W | 117.9 W | 106.0 V | 79.5 V | 12.42% |
| Solar Frontier KK SF135-S | 135.0 W | 122.5 W | 106.0 V | 80.0 V | 12.9% |
| Solar Frontier KK SF140-S | 140.0 W | 127.1 W | 107.0 V | 80.5 V | 13.37% |
| Solar Frontier KK SF145-S | 145.0 W | 131.2 W | 107.0 V | 81.0 V | 13.85% |
How Many Solar Frontier KK SF140-S Modules Fit in a Cold-Weather String?
Maximum series module counts for Solar Frontier KK SF140-S from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 120.48 V | 4 panels | 481.9 V | 8 panels |
| -10 C (14 F) | 117.49 V | 5 panels | 587.4 V | 8 panels |
| 0 C (32 F) | 114.49 V | 5 panels | 572.4 V | 8 panels |
| 25 C (77 F STC) | 107.0 V | 5 panels | 535.0 V | 9 panels |
Which Cross-Brand Solar Modules Compare Closest to Solar Frontier KK SF140-S?
Alternative CEC solar modules from competing brands near Solar Frontier KK SF140-S (140.0 W), including Du Pont Apollo DA105-A2.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Du Pont Apollo DA105-A2 Du Pont Apollo |
105.0 W | -35.0 W | 100.0 V | 6.82% | 91.0% |
| Du Pont Apollo DA102-A6 Du Pont Apollo |
102.0 W | -38.0 W | 100.0 V | 6.62% | 94.2% |
| Applied Materials 1/4 Size Single Junction Version 10 Applied Materials |
116.0 W | -24.0 W | 96.2 V | 8.11% | 93.0% |
| Du Pont Apollo DA095-A2 Du Pont Apollo |
95.0 W | -45.0 W | 100.0 V | 6.17% | 90.8% |
What Are the Design Limits and Best-Fit Uses for Solar Frontier KK SF140-S?
Evaluate Solar Frontier KK SF140-S (140.0 W STC, 107.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Solar Frontier KK SF140-S reaches 120.48 V per panel—exceeding 4 panels in series voids 600 V inverter warranties.
- Footprint constraint: 58 panels for an 8 kW build require 654 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 58 panels (654 sq ft).
- 2026 tax credit baseline: cash residential installs of Solar Frontier KK SF140-S carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Solar Frontier KK SF140-S 8 kW Residential Fit
Needs 58 modules (654 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 5 panels (-10 C) or 4 panels (-20 C), or compare Du Pont Apollo DA105-A2.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 127.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Solar Frontier KK SF140-S by Solar Frontier KK grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Solar Frontier KK SF140-S PTC wattage (127.1 W) lower than STC (140.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 127.1 W PTC (90.8% retention) across Solar Frontier KK SF140-S's 1.047 m2 aperture.
Who should skip Solar Frontier KK SF140-S on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 58 Solar Frontier KK SF140-S panels (654 sq ft) leave unusable roof gaps vs. Du Pont Apollo DA105-A2.
What is the 1,000 V commercial string limit for Solar Frontier KK SF140-S?
On 1,000 V commercial inverters at -10 C (117.49 V cold Voc), Solar Frontier KK SF140-S fits up to 8 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Solar Frontier KK SF140-S.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)