Skip to main content
WireAndSun
Calculators
CEC PV Module

Shanghai ST Solar STP200-48 — CEC Solar Module Specifications

Manufacturer: Shanghai ST Solar Registry: CEC Verified Engineering Specification

Shanghai ST Solar STP200-48 is a 200.0 W STC (179.4 W PTC) Multi-c-Si solar module ranking #21,027 of 21,677 CEC listings (below all-CEC median; higher than 2.7% of peers). It delivers 14.96% efficiency, 30.0 V Voc at 25 C, and 33.36 V cold Voc at -10 C (17 panels max per 600 V string).

STC Wattage
200.0 W
PTC Wattage
179.4 W
Voc @ 25C
30.0 V
Efficiency
14.96%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Shanghai ST Solar STP200-48 Compare Against Peer CEC Listings?

Engineering position of Shanghai ST Solar STP200-48 (200.0 W STC) vs. Centrosolar America DP48 200 across 1,407 CEC Multi-c-Si solar modules.

Built with 48 Multi-c-Si cells, Shanghai ST Solar STP200-48 pairs typical 89.7% PTC-to-STC thermal output (179.4 W real-world rating) with 30.0 V nominal Voc. An 8 kW residential build (8,000 W DC, 7,176 W PTC) saves ~$2,002/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Centrosolar America DP48 200 offers a 200.0 W alternative.

Where Does Shanghai ST Solar STP200-48 Fall Across Listed CEC Models?

Plots Shanghai ST Solar STP200-48 at 200.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Shanghai ST Solar STP200-48 (200.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCShanghai ST Solar : 200.0 W

What Dataset Percentiles Define Shanghai ST Solar STP200-48?

Benchmarks Shanghai ST Solar STP200-48 on STC wattage, thermal PTC/STC retention, and 14.96 aperture conversion efficiency against CEC peers.

Shanghai ST Solar STP200-48 Engineering BenchmarksPercentile comparison of Shanghai ST Solar STP200-48 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage200.0 WPTC/STC Retention89.7%Module Efficiency14.96%

What Do the Dataset Ranks Show for Shanghai ST Solar STP200-48?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Shanghai ST Solar STP200-48 by Shanghai ST Solar.

Rank #21,027 / 21,677

200.0 W STC · Higher Than 2.7%

200.0 W STC (-185.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #19,793

14.96% Aperture Efficiency

Power density 149.6 W/m2 (4.95 percentage points below 19.91% CEC median). PTC/STC ratio: 89.7% (rank #19,653).

NEC 690.7 Limit

17 Panels Max @ -10 C (600 V)

Cold Voc reaches 33.36 V at -10 C (567.1 V string) and 34.32 V at -20 C (17 max).

8 kW Reference Array

40 Panels = 8,000 W STC

Occupies 53.5 m2 (576 sq ft) producing 7,176 W PTC; NEC 690.8 OCPD floor is 14.45 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 30.0 * (1 + (-0.32/100) * (-10 - 25)) = 33.36 V | OCPD = 1.56 * 9.26 = 14.45 A

Inputs from CEC Modules.csv for Shanghai ST Solar STP200-48: Voc=30.0 V, beta_Voc=-0.32%/C, Isc=9.26 A, STC=200.0 W, Area=1.337 m2.

Result: 17 panels max on 600 V (567.1 V); 40 panels for 8 kW (576 sq ft).

What Are the Published CEC Specifications for Shanghai ST Solar STP200-48?

Laboratory test ratings recorded for Shanghai ST Solar STP200-48 (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Shanghai ST Solar STP200-48.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 200.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 179.4 W (89.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 30.0 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.26 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 24.0 V / 8.33 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.32 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.96% (1.337 m2) Array roof footprint density
Cell Count & Technology 48 cells (Multi-c-Si) Monofacial backsheet

How Many Shanghai ST Solar STP200-48 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (576 sq ft at 8 kW), and estimated Year-1 electric bill offset for Shanghai ST Solar STP200-48.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 30 6.0 kW 432 sq ft $1,502 $2,539
8 kW Class 40 8.0 kW 576 sq ft $2,002 $3,386
10 kW Class 50 10.0 kW 720 sq ft $2,503 $4,232

How Many Shanghai ST Solar STP200-48 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Shanghai ST Solar STP200-48 (beta_Voc -0.32%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=30.0V and beta_Voc=-0.32%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 34.32 V 17 panels 583.4 V 29 panels
-10 C (14 F) 33.36 V 17 panels 567.1 V 29 panels
0 C (32 F) 32.4 V 18 panels 583.2 V 30 panels
25 C (77 F STC) 30.0 V 20 panels 600.0 V 33 panels

Which Cross-Brand Solar Modules Compare Closest to Shanghai ST Solar STP200-48?

Closest cross-brand CEC competitors to Shanghai ST Solar STP200-48 matched near 200.0 W STC and 30.0 V Voc, led by Centrosolar America DP48 200.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Centrosolar America DP48 200
Centrosolar America
200.0 W Tie (0 W) 30.12 V 15.09% 88.6%
Gintung Energy ASEC-210G6M68
Gintung Energy
210.0 W +10.0 W 30.14 V 16.1% 88.1%
Gintung Energy ASEC-210G6S68
Gintung Energy
210.0 W +10.0 W 30.14 V 16.1% 87.8%
Gintung Energy GTEC-210G6M68
Gintung Energy
210.0 W +10.0 W 30.14 V 16.1% 88.1%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Shanghai ST Solar STP200-48?

Evaluate Shanghai ST Solar STP200-48 (200.0 W STC, 30.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Shanghai ST Solar STP200-48 reaches 34.32 V per panel—exceeding 17 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 40 panels for an 8 kW build require 576 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 40 panels (576 sq ft).
  • 2026 tax credit baseline: cash residential installs of Shanghai ST Solar STP200-48 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Shanghai ST Solar STP200-48 8 kW Residential Fit

Needs 40 modules (576 sq ft) with a 15 A string OCPD, offsetting ~$2,002/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 17 panels (-10 C) or 17 panels (-20 C), or compare Centrosolar America DP48 200.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 179.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Shanghai ST Solar STP200-48 by Shanghai ST Solar grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Shanghai ST Solar STP200-48?

Multiplying Shanghai ST Solar STP200-48's 9.26 A short-circuit current by 1.56 equals 14.45 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Shanghai ST Solar STP200-48 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 33.36 V cold Voc at 14 F and handles 9.26 A Isc; string inverters cap Shanghai ST Solar STP200-48 at 17 panels on 600 V.

Is Shanghai ST Solar STP200-48 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Shanghai ST Solar STP200-48 rely on utility bill offset (~$2,002/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.