Gintung Energy GTEC-210G6M68 is a 210.0 W STC (185.0 W PTC) Multi-c-Si solar module ranking #20,916 of 21,677 CEC listings (below all-CEC median; higher than 3.2% of peers). It delivers 16.1% efficiency, 30.14 V Voc at 25 C, and 33.76 V cold Voc at -10 C (17 panels max per 600 V string).
- STC Wattage
- 210.0 W
- PTC Wattage
- 185.0 W
- Voc @ 25C
- 30.14 V
- Efficiency
- 16.1%
How Does Gintung Energy GTEC-210G6M68 Compare Against Peer CEC Listings?
Solar engineering breakdown for Gintung Energy GTEC-210G6M68: PTC thermal retention, roof footprint, and cold Voc string bounds. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
Measured at 210.0 W STC and 185.0 W PTC, Gintung Energy GTEC-210G6M68 sits -175.0 W vs all-CEC median (below all-CEC median; higher than 3.2% of peers) among 21,677 listed modules. Power density reaches 161.0 W/m2 (3.81 percentage points below 19.91% CEC median). Lower 30.14 V string voltage fits 17 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 29 panels in series. Alternative peer Centrosolar America DP48 200 rates 200.0 W.
Where Does Gintung Energy GTEC-210G6M68 Fall Across Listed CEC Models?
Distribution marker showing Gintung Energy GTEC-210G6M68 (210.0 W) relative to the 385.0 W all-CEC solar panel median. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
What Dataset Percentiles Define Gintung Energy GTEC-210G6M68?
Dataset percentiles tracking Gintung Energy GTEC-210G6M68 power output, thermal retention ratio, and aperture efficiency against 21,677 models. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
What Do the Dataset Ranks Show for Gintung Energy GTEC-210G6M68?
Benchmark highlights for Gintung Energy GTEC-210G6M68 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
210.0 W STC · Higher Than 3.2%
210.0 W STC (-175.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
16.1% Aperture Efficiency
Power density 161.0 W/m2 (3.81 percentage points below 19.91% CEC median). PTC/STC ratio: 88.1% (rank #21,362).
17 Panels Max @ -10 C (600 V)
Cold Voc reaches 33.76 V at -10 C (573.9 V string) and 34.79 V at -20 C (17 max).
39 Panels = 8,190 W STC
Occupies 50.9 m2 (547 sq ft) producing 7,215 W PTC; NEC 690.8 OCPD floor is 14.02 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 30.14 * (1 + (-0.343/100) * (-10 - 25)) = 33.76 V | OCPD = 1.56 * 8.99 = 14.02 A
Inputs from CEC Modules.csv for Gintung Energy GTEC-210G6M68: Voc=30.14 V, beta_Voc=-0.343%/C, Isc=8.99 A, STC=210.0 W, Area=1.304 m2.
Result: 17 panels max on 600 V (573.9 V); 39 panels for 8 kW (547 sq ft).
What Are the Published CEC Specifications for Gintung Energy GTEC-210G6M68?
Official CEC datasheet figures for Gintung Energy GTEC-210G6M68 (Multi-c-Si) used in utility interconnection and permit reviews. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 210.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 185.0 W (88.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 30.14 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.99 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 24.33 V / 8.63 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.343 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 16.1% (1.304 m2) | Array roof footprint density |
| Cell Count & Technology | 48 cells (Multi-c-Si) | Monofacial backsheet |
How Many Gintung Energy GTEC-210G6M68 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Gintung Energy GTEC-210G6M68 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 29 | 6.09 kW | 407 sq ft | $1,524 | $2,577 |
| 8 kW Class | 39 | 8.19 kW | 547 sq ft | $2,050 | $3,466 |
| 10 kW Class | 48 | 10.08 kW | 674 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This Gintung Energy Series?
Consolidated Gintung Energy wattage variants sharing the Gintung Energy GTEC-210G6M68 mechanical and cell layout. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Gintung Energy GTEC-200G6M68 | 200.0 W | 175.9 W | 29.95 V | 24.07 V | 15.33% |
| Gintung Energy GTEC-205G6M68 | 205.0 W | 180.5 W | 30.03 V | 24.23 V | 15.71% |
| Gintung Energy GTEC-210G6M68 | 210.0 W | 185.0 W | 30.14 V | 24.33 V | 16.1% |
| Gintung Energy GTEC-215G6M68 | 215.0 W | 189.6 W | 30.27 V | 24.46 V | 16.48% |
| Gintung Energy GTEC-220G6M68 | 220.0 W | 194.2 W | 30.4 V | 24.58 V | 16.86% |
How Many Gintung Energy GTEC-210G6M68 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Gintung Energy GTEC-210G6M68 (33.76 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 34.79 V | 17 panels | 591.4 V | 28 panels |
| -10 C (14 F) | 33.76 V | 17 panels | 573.9 V | 29 panels |
| 0 C (32 F) | 32.72 V | 18 panels | 589.0 V | 30 panels |
| 25 C (77 F STC) | 30.14 V | 19 panels | 572.7 V | 33 panels |
Which Cross-Brand Solar Modules Compare Closest to Gintung Energy GTEC-210G6M68?
Competing CEC solar panels closest to Gintung Energy GTEC-210G6M68 in nameplate wattage and Voc, starting with Centrosolar America DP48 200.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Centrosolar America DP48 200 Centrosolar America |
200.0 W | -10.0 W | 30.12 V | 15.09% | 88.6% |
| Centrosolar America DP54 210 Centrosolar America |
210.0 W | Tie (0 W) | 33.23 V | 14.16% | 88.4% |
| APOS Energy AS210 APOS Energy |
210.0 W | Tie (0 W) | 33.5 V | 14.0% | 89.7% |
| Hanwha Qcells (Qidong) Co Ltd SF190-27-P205 Hanwha Qcells (Qidong) Co Ltd |
205.0 W | -5.0 W | 32.9 V | 13.72% | 88.9% |
What Are the Design Limits and Best-Fit Uses for Gintung Energy GTEC-210G6M68?
Evaluate Gintung Energy GTEC-210G6M68 (210.0 W STC, 30.14 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Gintung Energy GTEC-210G6M68 reaches 34.79 V per panel—exceeding 17 panels in series voids 600 V inverter warranties.
- Footprint constraint: 39 panels for an 8 kW build require 547 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 39 panels (547 sq ft).
- 2026 tax credit baseline: cash residential installs of Gintung Energy GTEC-210G6M68 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Gintung Energy GTEC-210G6M68 8 kW Residential Fit
Needs 39 modules (547 sq ft) with a 15 A string OCPD, offsetting ~$2,050/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 17 panels (-10 C) or 17 panels (-20 C), or compare Centrosolar America DP48 200.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 185.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Gintung Energy GTEC-210G6M68 by Gintung Energy grounded in CEC test data and NEC 690.7/690.8 limits.
How many Gintung Energy GTEC-210G6M68 panels fit on a 600 V winter solar string?
At -10 C (14 F), Gintung Energy GTEC-210G6M68 cold Voc rises from 30.14 V to 33.76 V (beta_Voc -0.343%/C), capping a 600 V string at 17 panels (573.9 V).
How much roof area does an 8 kW array of Gintung Energy GTEC-210G6M68 need?
An 8 kW DC system uses 39 Gintung Energy GTEC-210G6M68 modules (8,190 W STC / 7,215 W PTC), covering roughly 547 sq ft and saving ~$2,050/yr at 18.54 c/kWh.
How does Gintung Energy GTEC-210G6M68 compare against Centrosolar America DP48 200?
Gintung Energy GTEC-210G6M68 outputs 210.0 W STC (30.14 V Voc, rank #20,916 of 21,677), while Centrosolar America DP48 200 delivers 200.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)