Manufacturer: REC Group Registry: CEC Verified Engineering Specification

REC Group REC345NP2 Black is a 345.0 W STC (324.5 W PTC) Mono-c-Si solar module ranking #13,309 of 21,677 CEC listings (below all-CEC median; higher than 37.4% of peers). It delivers 19.49% efficiency, 40.4 V Voc at 25 C, and 43.96 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
345.0 W
PTC Wattage
324.5 W
Voc @ 25C
40.4 V
Efficiency
19.49%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does REC Group REC345NP2 Black Compare Against Peer CEC Listings?

How REC Group REC Group REC345NP2 Black handles rooftop heat (324.5 W PTC), 8 kW sizing, and cold winter string voltage.

REC Group builds the REC Group REC345NP2 Black (Mono-c-Si) as a compact residential or specialty off-grid module delivering 194.9 W/m2 (0.42 percentage points below 19.91% CEC median). Compared against Caterpillar Inc PVC345MP03HA (345.0 W), this model holds strong 94.1% PTC-to-STC heat retention (#4,203 of 21,677). Mid-range 40.4 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F, while NEC 690.8 sets a 17.46 A overcurrent floor served by a 20 A breaker.

Where Does REC Group REC345NP2 Black Fall Across Listed CEC Models?

Where REC Group REC345NP2 Black (345.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where REC Group REC345NP2 Black (345.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCREC Group REC345NP: 345.0 W

What Dataset Percentiles Define REC Group REC345NP2 Black?

Percentile placement of REC Group REC345NP2 Black across power density (194.9 W/m2), thermal retention, and nameplate STC wattage.

REC Group REC345NP2 Black Engineering BenchmarksPercentile comparison of REC Group REC345NP2 Black wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage345.0 WPTC/STC Retention94.1%Module Efficiency19.49%

What Do the Dataset Ranks Show for REC Group REC345NP2 Black?

Four critical engineering numbers homeowners and solar installers check first when reviewing REC Group REC345NP2 Black specifications. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Rank #13,309 / 21,677

345.0 W STC · Higher Than 37.4%

345.0 W STC (-40.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #12,236

19.49% Aperture Efficiency

Power density 194.9 W/m2 (0.42 percentage points below 19.91% CEC median). PTC/STC ratio: 94.1% (rank #4,203).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 43.96 V at -10 C (571.5 V string) and 44.98 V at -20 C (13 max).

8 kW Reference Array

24 Panels = 8,280 W STC

Occupies 42.5 m2 (457 sq ft) producing 7,788 W PTC; NEC 690.8 OCPD floor is 17.46 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 40.4 * (1 + (-0.252/100) * (-10 - 25)) = 43.96 V | OCPD = 1.56 * 11.19 = 17.46 A

Inputs from CEC Modules.csv for REC Group REC345NP2 Black: Voc=40.4 V, beta_Voc=-0.252%/C, Isc=11.19 A, STC=345.0 W, Area=1.77 m2.

Result: 13 panels max on 600 V (571.5 V); 24 panels for 8 kW (457 sq ft).

What Are the Published CEC Specifications for REC Group REC345NP2 Black?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for REC Group REC345NP2 Black.

Official California Energy Commission (NREL SAM) test parameters for REC Group REC345NP2 Black.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 345.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 324.5 W (94.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 40.4 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 11.19 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 32.7 V / 10.54 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.252 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 19.49% (1.77 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many REC Group REC345NP2 Black Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using REC Group REC345NP2 Black (345.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 18 6.21 kW 343 sq ft $1,554 $2,628
8 kW Class 24 8.28 kW 457 sq ft $2,072 $3,504
10 kW Class 29 10.01 kW 553 sq ft $2,505 $4,236

Which Sibling Wattage & Trim Variants Belong to This REC Group Series?

All closely matched REC Group wattages and cosmetic trims sharing the REC Group REC345NP2 Black architecture. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Sibling CEC listings grouped into the REC Group REC345NP2 Black wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
REC Group REC345NP2 345.0 W 324.5 W 40.4 V 32.7 V 19.49%
REC Group REC345NP2 Black 345.0 W 324.5 W 40.4 V 32.7 V 19.49%

How Many REC Group REC345NP2 Black Modules Fit in a Cold-Weather String?

Maximum series module counts for REC Group REC345NP2 Black from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=40.4V and beta_Voc=-0.252%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 44.98 V 13 panels 584.7 V 22 panels
-10 C (14 F) 43.96 V 13 panels 571.5 V 22 panels
0 C (32 F) 42.95 V 13 panels 558.4 V 23 panels
25 C (77 F STC) 40.4 V 14 panels 565.6 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to REC Group REC345NP2 Black?

Alternative CEC solar modules from competing brands near REC Group REC345NP2 Black (345.0 W), including Caterpillar Inc PVC345MP03HA.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Caterpillar Inc PVC345MP03HA
Caterpillar Inc
345.0 W Tie (0 W) 40.2 V 19.49% 93.3%
ELITE Solar ET-M660BH345BB
ELITE Solar
345.0 W Tie (0 W) 39.9 V 19.17% 93.5%
CSI Solar Co Ltd CS3L-345MS
CSI Solar Co Ltd
345.0 W Tie (0 W) 39.8 V 19.27% 92.9%
DualSun SAS DualSun 340M-120-00
DualSun SAS
340.0 W -5.0 W 40.1 V 18.78% 93.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for REC Group REC345NP2 Black?

Evaluate REC Group REC345NP2 Black (345.0 W STC, 40.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), REC Group REC345NP2 Black reaches 44.98 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 24 panels for an 8 kW build require 457 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (457 sq ft).
  • 2026 tax credit baseline: cash residential installs of REC Group REC345NP2 Black carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

REC Group REC345NP2 Black 8 kW Residential Fit

Needs 24 modules (457 sq ft) with a 20 A string OCPD, offsetting ~$2,072/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Caterpillar Inc PVC345MP03HA.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 324.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for REC Group REC345NP2 Black by REC Group grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for REC Group REC345NP2 Black?

Multiplying REC Group REC345NP2 Black's 11.19 A short-circuit current by 1.56 equals 17.46 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can REC Group REC345NP2 Black pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 43.96 V cold Voc at 14 F and handles 11.19 A Isc; string inverters cap REC Group REC345NP2 Black at 13 panels on 600 V.

Is REC Group REC345NP2 Black eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of REC Group REC345NP2 Black rely on utility bill offset (~$2,072/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.