Skip to main content
WireAndSun
Calculators
CEC PV Module

REC Group REC660AA Pro L — CEC Solar Module Specifications

Manufacturer: REC Group Registry: CEC Verified Engineering Specification

REC Group REC660AA Pro L is a 660.0 W STC (618.3 W PTC) Mono-c-Si solar module ranking #417 of 21,677 CEC listings (top 2.1%; higher than 97.9% of peers). It delivers 21.57% efficiency, 49.2 V Voc at 25 C, and 53.78 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
660.0 W
PTC Wattage
618.3 W
Voc @ 25C
49.2 V
Efficiency
21.57%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does REC Group REC660AA Pro L Compare Against Peer CEC Listings?

Engineering position of REC Group REC660AA Pro L (660.0 W STC) vs. Risen Energy Co Ltd RSM132-8-660BHDG across 5,889 CEC Mono-c-Si solar modules.

Ranking #417 across 21,677 CEC solar panels (top 2.1%; higher than 97.9% of peers), REC Group REC660AA Pro L operates as a large-format commercial and ground-mount module sitting 250.0 W above the 410.0 W Mono-c-Si median. Higher 49.2 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C). With strong 93.7% PTC-to-STC heat retention (#6,162 of 21,677), 13 panels occupy 428 sq ft and offset roughly $2,147/yr at average US rates (or $3,631/yr in California). Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes.

Where Does REC Group REC660AA Pro L Fall Across Listed CEC Models?

Plots REC Group REC660AA Pro L at 660.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where REC Group REC660AA Pro L (660.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCREC Group REC660AA: 660.0 W

What Dataset Percentiles Define REC Group REC660AA Pro L?

Benchmarks REC Group REC660AA Pro L on STC wattage, thermal PTC/STC retention, and 21.57 aperture conversion efficiency against CEC peers.

REC Group REC660AA Pro L Engineering BenchmarksPercentile comparison of REC Group REC660AA Pro L wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage660.0 WPTC/STC Retention93.7%Module Efficiency21.57%

What Do the Dataset Ranks Show for REC Group REC660AA Pro L?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for REC Group REC660AA Pro L by REC Group.

Rank #417 / 21,677

Top 2.1% STC Output

660.0 W STC (+275.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #4,218

21.57% Aperture Efficiency

Power density 215.7 W/m2 (1.66 percentage points above 19.91% CEC median). PTC/STC ratio: 93.7% (rank #6,162).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 53.78 V at -10 C (591.6 V string) and 55.09 V at -20 C (10 max).

8 kW Reference Array

13 Panels = 8,580 W STC

Occupies 39.8 m2 (428 sq ft) producing 8,038 W PTC; NEC 690.8 OCPD floor is 25.51 A (30 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.2 * (1 + (-0.266/100) * (-10 - 25)) = 53.78 V | OCPD = 1.56 * 16.35 = 25.51 A

Inputs from CEC Modules.csv for REC Group REC660AA Pro L: Voc=49.2 V, beta_Voc=-0.266%/C, Isc=16.35 A, STC=660.0 W, Area=3.06 m2.

Result: 11 panels max on 600 V (591.6 V); 13 panels for 8 kW (428 sq ft).

What Are the Published CEC Specifications for REC Group REC660AA Pro L?

Laboratory test ratings recorded for REC Group REC660AA Pro L (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for REC Group REC660AA Pro L.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 660.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 618.3 W (93.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 49.2 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 16.35 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 42.4 V / 15.6 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.266 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.57% (3.06 m2) Array roof footprint density
Cell Count & Technology 66 cells (Mono-c-Si) Bifacial glass-glass

How Many REC Group REC660AA Pro L Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (428 sq ft at 8 kW), and estimated Year-1 electric bill offset for REC Group REC660AA Pro L.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 10 6.6 kW 329 sq ft $1,652 $2,793
8 kW Class 13 8.58 kW 428 sq ft $2,147 $3,631
10 kW Class 16 10.56 kW 527 sq ft $2,643 $4,469

Which Sibling Wattage & Trim Variants Belong to This REC Group Series?

Sibling wattage bins and frame colors grouped with REC Group REC660AA Pro L under REC Group to prevent duplicate spec pages.

Sibling CEC listings grouped into the REC Group REC660AA Pro L wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
REC Group REC650AA Pro L 650.0 W 608.7 W 49.1 V 42.2 V 21.24%
REC Group REC660AA Pro L 660.0 W 618.3 W 49.2 V 42.4 V 21.57%
REC Group REC670AA Pro L 670.0 W 628.0 W 49.2 V 42.5 V 21.9%

How Many REC Group REC660AA Pro L Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for REC Group REC660AA Pro L (beta_Voc -0.266%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=49.2V and beta_Voc=-0.266%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 55.09 V 10 panels 550.9 V 18 panels
-10 C (14 F) 53.78 V 11 panels 591.6 V 18 panels
0 C (32 F) 52.47 V 11 panels 577.2 V 19 panels
25 C (77 F STC) 49.2 V 12 panels 590.4 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to REC Group REC660AA Pro L?

Closest cross-brand CEC competitors to REC Group REC660AA Pro L matched near 660.0 W STC and 49.2 V Voc, led by Risen Energy Co Ltd RSM132-8-660BHDG.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Risen Energy Co Ltd RSM132-8-660BHDG
Risen Energy Co Ltd
660.0 W Tie (0 W) 49.11 V 21.22% 95.3%
Trina Solar CoLtd TSM-660NEG21C20
Trina Solar CoLtd
660.0 W Tie (0 W) 46.6 V 21.43% 94.6%
Trina Solar TSM-650NEG19RC20
Trina Solar
650.0 W -10.0 W 49.77 V 24.25% 94.6%
Trina Solar TSM-660DEG21C20
Trina Solar
660.0 W Tie (0 W) 45.9 V 21.43% 94.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for REC Group REC660AA Pro L?

Evaluate REC Group REC660AA Pro L (660.0 W STC, 49.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), REC Group REC660AA Pro L reaches 55.09 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 13 panels for an 8 kW build require 428 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of REC Group REC660AA Pro L carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

REC Group REC660AA Pro L 8 kW Residential Fit

Needs 13 modules (428 sq ft) with a 30 A string OCPD, offsetting ~$2,147/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Risen Energy Co Ltd RSM132-8-660BHDG.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 618.3 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for REC Group REC660AA Pro L by REC Group grounded in CEC test data and NEC 690.7/690.8 limits.

How many REC Group REC660AA Pro L panels fit on a 600 V winter solar string?

At -10 C (14 F), REC Group REC660AA Pro L cold Voc rises from 49.2 V to 53.78 V (beta_Voc -0.266%/C), capping a 600 V string at 11 panels (591.6 V).

How much roof area does an 8 kW array of REC Group REC660AA Pro L need?

An 8 kW DC system uses 13 REC Group REC660AA Pro L modules (8,580 W STC / 8,038 W PTC), covering roughly 428 sq ft and saving ~$2,147/yr at 18.54 c/kWh.

How does REC Group REC660AA Pro L compare against Risen Energy Co Ltd RSM132-8-660BHDG?

REC Group REC660AA Pro L outputs 660.0 W STC (49.2 V Voc, rank #417 of 21,677), while Risen Energy Co Ltd RSM132-8-660BHDG delivers 660.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.